文献速递关节外科

植入物设计的演变降低初次全膝关节置换术中外侧松解的发生率

The Evolution of Implant Design Decreases the Incidence of Lateral Release in Primary Total Knee Arthroplasty.
PubMed 文献 · J Arthroplasty · 2016-12-14

该研究回顾性分析了单一资深外科医生1980至2015年间连续1991例初次全膝关节置换术记录,比较Press-Fit Condylar(PFC)、Sigma和ATTUNE三种连续全膝植入物设计下外侧松解的使用情况。多因素分析显示,与ATTUNE相比,PFC植入物患者校正后外侧松解比值比更高(OR 6.35,95%CI 3.85,10.49),Sigma植入物患者亦更高(OR 2.02,95%CI 1.26,3.23);固定平台植入物与更高的校正后外侧松解比值比相关(OR 1.80,95%CI 1.24,2.62)。结论认为较老的膝关节植入物与更高的外侧松解使用率相关,随着设计迭代,平衡髌股关节所需的外侧松解减少。

要点

  • 与ATTUNE相比,PFC植入物校正后外侧松解OR为6.35(95%CI 3.85,10.49)。
  • 与ATTUNE相比,Sigma植入物校正后外侧松解OR为2.02(95%CI 1.26,3.23)。
  • 固定平台植入物校正后外侧松解OR为1.80(95%CI 1.24,2.62)。

核心结论

  • 较老的膝关节植入物与更高的外侧松解使用率相关,随着连续设计迭代,平衡髌股关节所需的外侧松解减少。
  • 作者认为,持续改进设计以匹配原生膝关节解剖可能在未来设计中进一步改善髌股关节的稳定性。

研究设计与样本

  • 回顾性综述单一资深外科医生实践中连续全膝关节置换术病例,涉及Press-Fit Condylar(PFC)、Sigma和ATTUNE(DePuy, Warsaw, IN)三种连续全膝设计。
  • 评估每种植入物类型下外侧松解的使用情况,以确定设计变化是否改善髌骨稳定性、减少外侧松解需求。
  • 采用多因素分析确定植入物类型与外侧松解之间的关联,并校正年龄、性别、术前对线和轴承类型。

主要发现

  • 评估了1980至2015年间施行的1991例初次全膝关节置换术记录。
  • 与ATTUNE相比,接受PFC植入物患者的校正后外侧松解比值比更高(OR 6.35,95%CI 3.85,10.49)。
  • 与ATTUNE相比,接受Sigma植入物患者的校正后外侧松解比值比更高(OR 2.02,95%CI 1.26,3.23)。
  • 固定平台植入物与更高的校正后外侧松解比值比相关(OR 1.80,95%CI 1.24,2.62)。

关键数值与推荐

  • 与ATTUNE相比,PFC植入物校正后外侧松解OR 6.35(95%CI 3.85,10.49)。
  • 与ATTUNE相比,Sigma植入物校正后外侧松解OR 2.02(95%CI 1.26,3.23)。
  • 固定平台植入物校正后外侧松解OR 1.80(95%CI 1.24,2.62)。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Appropriate balancing of the patellofemoral joint (PFJ) using a lateral release can help to prevent patellar instability in total knee arthroplasty (TKA). Contemporary total knee implant designs are characterized by enhanced trochlear geometry more similar to native knee anatomy to minimize instability and reduce utilization of a lateral release. METHODS: We retrospectively reviewed consecutive TKA cases from a single senior surgeon's practice with 3 successive total knee designs: the Press-Fit Condylar (PFC), the Sigma, and the ATTUNE (DePuy, Warsaw, IN). We evaluated the use of lateral release with each implant type to determine if design changes have improved patellar stability, reducing the need for lateral release. We used multivariate analysis to determine the association between implant type and lateral release, adjusting for age, sex, preoperative alignment, and bearing type. RESULTS: We evaluated 1991 records of primary TKAs performed from 1980-2015. As compared with the ATTUNE, the adjusted odds of lateral release were greater for patients receiving PFC implants (Odds ratio [OR] 6.35, 95% confidence interval [CI] 3.85,10.49) and Sigma implants (OR 2.02, 95% CI 1.26, 3.23). In addition, fixed bearing implants were associated with greater adjusted odds of lateral release (OR 1.80, 95% CI 1.24, 2.62). CONCLUSION: We found that older knee implants were associated with higher use of lateral release, with successive designs the need for lateral release to balance the PFJ decreased. Continued design improvements to match the native knee anatomy may further improve the stability of the PFJ in future designs.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Webb JE, Yang HY, Collins JE, et al. The Evolution of Implant Design Decreases the Incidence of Lateral Release in Primary Total Knee Arthroplasty. J Arthroplasty. 2016. PMID: 28089467. doi:10.1016/j.arth.2016.11.050

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。