发育性髋关节发育不良髋中非骨水泥股骨柄前倾:锥形楔形柄与干骺端填充柄的比较
该回顾性研究比较了78例干骺端填充柄与83例锥形楔形柄全髋关节置换术髋的前倾增加量,发现锥形楔形柄组前倾增加量(22.7°±11.6°)大于干骺端填充柄组(17.2°±8.3°;P=.0007),且变异更大(P=.0016),干骺端填充柄组与股骨前倾的相关性更高。结论认为股骨前倾对股骨柄前倾的影响因柄几何形状而异,锥形楔形柄的术前前倾增加量难以预估。
要点
- 锥形楔形柄组前倾增加量22.7°±11.6°,大于干骺端填充柄组的17.2°±8.3°(P=.0007)。
- 锥形楔形柄组前倾增加量的变异显著大于干骺端填充柄组(P=.0016)。
- 干骺端填充柄组与股骨前倾的相关性高于锥形楔形柄组。
核心结论
- 股骨前倾对股骨柄前倾的影响因柄几何形状而异。
- 锥形楔形柄的前倾增加变异大于干骺端填充柄。
- 基于本研究结果,锥形楔形柄的术前前倾增加量难以预估。
研究设计与样本
- 回顾性比较两组因髋关节发育不良致骨关节炎行全髋关节置换术的髋。
- 干骺端填充柄组78髋,锥形楔形柄组83髋。
- 采用CT测量术前5个层面的股骨前倾和术后股骨柄前倾。
主要发现
- 锥形楔形柄组前倾增加量为22.7°±11.6°,干骺端填充柄组为17.2°±8.3°(P=.0007)。
- 锥形楔形柄组前倾增加量的变异显著大于干骺端填充柄组(P=.0016)。
- 干骺端填充柄组与股骨前倾呈更高的正相关,高于锥形楔形柄组。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Appropriate stem anteversion is important for achieving stability of the prosthetic joint in total hip arthroplasty. Anteversion of a cementless femoral stem is affected by the femoral canal morphology and varies according to stem geometry. We investigated the difference and variation of the increase in anteversion between 2 types of cementless stems, and the correlation between each stem and the preoperative femoral anteversion. METHODS: We retrospectively compared 2 groups of hips that underwent total hip arthroplasty using a metaphyseal filling stem (78 hips) or a tapered wedge stem (83 hips). All the patients had osteoarthritis due to hip dysplasia. Computed tomography was used to measure preoperative femoral anteversion at 5 levels and postoperative stem anteversion. RESULTS: The increase in anteversion of the tapered wedge stem group (22.7° ± 11.6°) was more than that of the metaphyseal filling stem group (17.2° ± 8.3°; P = .0007). The variation of the increase in the tapered wedge stem group was significantly larger than that in the metaphyseal filling stem group (P = .0016). The metaphyseal filling stem group was more highly and positively correlated with femoral anteversion than the tapered wedge stem group. CONCLUSION: Femoral anteversion affects stem anteversion differently according to stem geometry. The tapered wedge stems had greater variation of the increase in anteversion than did the metaphyseal filling stems. Based on the results of this study, it is difficult to preoperatively estimate the increase in stem anteversion for tapered wedge stems.
引用
- Taniguchi N, Jinno T, Koga D, et al. Cementless Hip Stem Anteversion in the Dysplastic Hip: A Comparison of Tapered Wedge vs Metaphyseal Filling. J Arthroplasty. 2016. PMID: 28110848. doi:10.1016/j.arth.2016.12.020
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。