翻修全髋关节置换术中模块化股骨连接部的外侧皮质支撑植骨支持
该研究回顾性分析了2004至2014年间28例使用非骨水泥模块化股骨假体联合皮质支撑同种异体植骨翻修全髋关节置换的病例,所有患者股骨缺损为Paprosky IIIA级或以上。平均随访5.4±3.9年,Harris髋关节评分从术前26±10分改善至末次随访71±10分(P<.001),西安大略和麦克马斯特大学骨关节炎指数评分从45±12分改善至76±12分(P<.001),96%的髋实现了植骨与宿主股骨愈合,作者认为该技术安全且临床与影像学结果满意。
要点
- 28例翻修全髋中,5例(18%)为凹槽锥形设计,23例(82%)为多孔圆柱形设计,均联合皮质支撑同种异体植骨。
- Harris髋关节评分从术前26±10分改善至末次随访71±10分(P<.001),西安大略和麦克马斯特大学骨关节炎指数评分从45±12分改善至76±12分(P<.001)。
- 96%的髋(27髋)实现皮质支撑植骨与宿主股骨愈合,平均下沉1.8±1.3 mm。
核心结论
- 在股骨骨量受损的情况下,使用模块化股骨柄并辅以皮质支撑同种异体植骨是安全的,并能提供满意的临床和影像学结果。
研究设计与样本
- 回顾性分析前瞻性收集的2004至2014年间28例翻修全髋关节置换术的临床和影像学数据,使用非骨水泥模块化股骨组件联合皮质支撑同种异体植骨以补充近端股骨骨缺损。
- 5例(18%)为凹槽锥形设计,23例(82%)为多孔圆柱形设计;所有患者股骨缺损为Paprosky IIIA级或以上;平均随访5.4±3.9年。
主要发现
- Harris髋关节评分从术前26±10分改善至末次随访71±10分(P<.001)。
- 西安大略和麦克马斯特大学骨关节炎指数评分从术前45±12分改善至末次随访76±12分(P<.001)。
- 89%(25髋)的翻修或转换全髋关节置换在末次随访时仍在位;3例(11%)患者接受再手术,其中2例因感染、1例因假体周围骨折。
- 末次随访时股骨组件对线无统计学显著变化(P=.161);平均下沉1.8±1.3 mm。
- 股骨直径从术后初始影像至末次随访影像平均增加9.1±5.1 mm(P<.001),皮质宽度平均增加4.5±2.2 mm(P<.001);27髋(96%)实现皮质支撑同种异体植骨与宿主股骨愈合。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: There is risk of junction failure when using modular femoral stems for revision total hip arthroplasty (THA), especially with loss of bone stock in the proximal femur. Using a cortical strut allograft may provide additional support of a modular femoral construct in revision THA. METHODS: We reviewed prospectively gathered clinical and radiographic data for 28 revision THAs performed from 2004 to 2014 using cementless modular femoral components with cortical strut allograft applied to supplement proximal femoral bone loss: 5 (18%) were fluted taper designs and 23 (82%) were porous cylindrical designs All the patients had a Paprosky grade IIIA or greater femoral defect. The mean follow-up was 5.4 ± 3.9 years. RESULTS: The Harris Hip Scores improved from 26 ± 10 points preoperatively to 71 ± 10 points at final follow-up (P < .001). The Western Ontario McMaster Universities Osteoarthritis Index scores improved from 45 ± 12 points preoperatively to 76 ± 12 points at final follow-up (P < .001). Eighty-nine percent (25 hips) of all revision or conversion THAs were in place at final follow-up. Three (11%) patients underwent reoperations, 2 for infection and 1 for periprosthetic fracture. There was no statistical significant change in femoral component alignment (P = .161) at final follow-up. Mean subsidence was 1.8 ± 1.3 mm at final follow-up. Femoral diameter increased from initial postoperative imaging to final follow-up imaging by a mean of 9.1 ± 5.1 mm (P < .001) and cortical width increased by a mean of 4.5 ± 2.2 mm (P < .001). Twenty-seven hips (96%) achieved union between the cortical strut allograft and the host femur. CONCLUSION: The use of a modular femoral stem in a compromised femur with a supplementary cortical strut allgraft is safe and provides satisfactory clinical and radiological outcomes.
引用
- Lim CT, Amanatullah DF, Huddleston JI, et al. Cortical Strut Allograft Support of Modular Femoral Junctions During Revision Total Hip Arthroplasty. J Arthroplasty. 2016. PMID: 28130016. doi:10.1016/j.arth.2016.12.011
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。