文献速递关节外科

定性α-防御素检测(Synovasure)在翻修全关节置换术中诊断假体周围感染的价值

Qualitative α-defensin test (Synovasure) for the diagnosis of periprosthetic infection in revision total joint arthroplasty.
PubMed 文献 · Bone Joint J · 2017-01-01

这项前瞻性诊断研究纳入50例有翻修指征的患者,采用定性Synovasure检测滑液α-防御素并与标准诊断方法比较。以改良MSIS标准分类,13例为感染翻修、36例为无菌翻修、1例结果不确定。Synovasure敏感度69%、特异度94%,阳性似然比12.46、阴性似然比0.33,曲线下面积0.82,诊断效能与组织学(p=0.0042)及单次阳性培养的细菌学(p=0.0327)相当。

要点

  • Synovasure定性检测α-防御素诊断假体周围感染的敏感度为69%、特异度为94%。
  • 阳性似然比12.46、阴性似然比0.33,曲线下面积0.82提示诊断准确性良好。
  • Synovasure诊断效能与组织学(p=0.0042)及单次阳性培养细菌学(p=0.0327)相当。

核心结论

  • Synovasure使用便捷且约十分钟即可获得结果,作者认为其可能作为诊断假体周围感染的有用辅助手段。

研究设计与样本

  • 前瞻性诊断研究纳入50例有翻修临床指征且符合纳入标准的患者,其中女性28例、男性22例,平均年龄65岁(范围20至89岁)。
  • 采用定性Synovasure检测α-防御素,并与假体周围感染的标准诊断方法进行比较。
  • 依据改良肌肉骨骼感染学会(MSIS)标准,13例归为感染性翻修,36例归为无菌性翻修,1例检测结果不确定。

主要发现

  • Synovasure检测诊断假体周围感染的敏感度为69%,特异度为94%。
  • 阳性似然比为12.46,阴性似然比为0.33。
  • 曲线下面积为0.82,显示对假体周围感染具有良好的诊断准确性。
  • 采用Hochberg法校正p值后,Synovasure诊断假体周围感染的效能与组织学相当(p=0.0042),与单次阳性培养的细菌学相当(p=0.0327)。

关键数值与推荐

  • 以改良MSIS标准为参考,Synovasure定性检测的敏感度为69%、特异度为94%。
  • 阳性似然比12.46、阴性似然比0.33,曲线下面积0.82。
  • Hochberg校正后与组织学比较p=0.0042,与单次阳性培养的细菌学比较p=0.0327。

临床怎么用

  • 作者认为Synovasure使用便捷、约十分钟出结果,可能作为假体周围感染诊断的有用辅助手段。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

AIMS: The diagnosis of periprosthetic joint infection (PJI) remains demanding due to limitations of all the available diagnostic tests. The synovial fluid marker, α-defensin, is a promising adjunct for the assessment of potential PJI. The purpose of this study was to investigate the qualitative assessment of α-defensin, using Synovasure to detect or exclude periprosthetic infection in total joint arthroplasty. PATIENTS AND METHODS: We studied 50 patients (28 women, 22 men, mean age 65 years; 20 to 89) with a clinical indication for revision arthroplasty who met the inclusion criteria of this prospective diagnostic study. The presence of α-defensin was determined using the qualitative Synovasure test and compared with standard diagnostic methods for PJI. Based on modified Musculoskeletal Infection Society (MSIS) criteria, 13 cases were categorised as septic and 36 as aseptic revisions. One test was inconclusive. RESULTS: The Synovasure test achieved a sensitivity of 69% and a specificity of 94%. The positive and negative likelihood ratios were 12.46 and 0.33, respectively. A good diagnostic accuracy for PJI, with an area under the curve of 0.82, was demonstrated. Adjusted p-values using the method of Hochberg showed that Synovasure is as good at diagnosing PJI as histology (p = 0.0042) and bacteriology with one positive culture (p = 0.0327). CONCLUSION: With its ease of use and rapid results after approximately ten minutes, Synovasure may be a useful adjunct in the diagnosis of PJI. Cite this article: Bone Joint J 2017;99-B:66-72.

来源:Bone Joint J,查看原文。版权归原作者所有。

引用

  1. Sigmund IK, Holinka J, Gamper J, et al. Qualitative α-defensin test (Synovasure) for the diagnosis of periprosthetic infection in revision total joint arthroplasty. Bone Joint J. 2017. PMID: 28053259. doi:10.1302/0301-620X.99B1.BJJ-2016-0295.R1

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。