解剖骨盆平面定位器在侧卧位全髋关节置换术中的效果
本研究纳入141例在本院接受全髋关节置换术的患者,术前分别用传统侧位固定装置和解剖骨盆平面(APP)侧位固定装置固定骨盆后拍摄骨盆正位X线片,用3D模板软件测量骨盆矢状面倾斜并比较两种装置的方差。结果显示APP装置较传统装置显著减小了矢状面倾斜的方差。
要点
- 传统装置矢状面倾斜相对功能骨盆平面(FPP)的平均偏差为-5.0°±4.8°(负值代表后倾),43%在5°以内。
- APP侧位装置矢状面倾斜相对APP的平均偏差为1.7°±3.1°(前倾),89%在5°以内。
- APP侧位装置显著减小了矢状面倾斜的方差。
核心结论
- 该装置有望以简单、微创且高成本效益的方式减小矢状面倾斜。
研究设计与样本
- 本研究在本院纳入141例接受全髋关节置换术的患者,术前骨盆固定后分别使用传统侧位固定装置和APP侧位固定装置拍摄骨盆正位X线片,用3D模板软件测量矢状面倾斜并比较两种装置的方差。
主要发现
- 传统装置矢状面倾斜相对FPP的平均偏差为-5.0°±4.8°(负值代表后倾),43%在FPP 5°以内。
- APP侧位装置矢状面倾斜相对APP的平均偏差为1.7°±3.1°(前倾),89%在APP 5°以内。
- APP侧位装置显著减小了矢状面倾斜的方差。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Total hip arthroplasty in the lateral position involves particularly large variance in the sagittal tilt of pelvis fixation, which affects the imprecision of the cup anteversion leading to poor outcomes. We have added an additional compression pad to an existing device, also to be used in the lateral position, but theoretically enabling fixation on the anatomical pelvic plane (APP) serving as the reference plane. The present study aims to evaluate the usefulness of this device in comparison with the conventional device. METHODS: We have studied 141 patients who underwent total hip arthroplasty at our hospital. Two frontal plain x-rays of the pelvis were obtained preoperatively for each patient after pelvis fixation; one with the conventional lateral fixation device and the other with an APP lateral fixation device. The sagittal tilt of the pelvis in each position was measured with 3D templating software, and variance in the sagittal tilt was compared between the 2 devices. RESULTS: The mean bias in sagittal tilt relative to the functional pelvic plane (FPP) in the conventional device was -5.0° ± 4.8° (minus mean backward tilt) and was within 5° relative to the functional pelvic plane in 43%. The mean bias in the sagittal tilt relative to the APP in the APP lateral position device was 1.7° ± 3.1° (forward tilt) and was within 5° relative to the APP in 89%. The APP lateral device significantly reduced the variance in the sagittal tilt. CONCLUSION: This device holds promise as a means of reducing the sagittal tilt in a simple, minimally invasive, and highly cost-effective manner.
引用
- Iwakiri K, Kobayashi A, Ohta Y, et al. Efficacy of the Anatomical-Pelvic-Plane Positioner in Total Hip Arthroplasty in the Lateral Decubitus Position. J Arthroplasty. 2016. PMID: 28041773. doi:10.1016/j.arth.2016.11.048