文献速递关节外科创伤骨科

肩关节翻修置换术中丙酸杆菌负荷的特征分析:137例培养阳性病例研究

Characterizing the Propionibacterium Load in Revision Shoulder Arthroplasty: A Study of 137 Culture-Positive Cases.
PubMed 文献 · J Bone Joint Surg Am · 2017-01-01

该研究纳入137例翻修肩关节置换术,每例至少4份标本培养且至少1份丙酸杆菌阳性,采用半定量标本丙酸值(0.1、1、2、3或4)评估生长量并计算肩丙酸评分。结果显示丙酸杆菌在培养阳性肩关节内分布不均,标本数量与来源显著影响培养结果,未发现可用于定义真性感染的有用阈值。

要点

  • 培养阳性肩关节中平均43%的标本无生长,液体培养阳性率32.6%低于软组织66.5%和植入物55.6%。
  • 男性肩丙酸评分3.56±3.74显著高于女性1.22±3.11(p<0.001),平均肩丙酸评分男性0.53±0.51亦显著高于女性0.19±0.43(p<0.001)。
  • 未发现可用于定义真性感染的有用阈值。

核心结论

  • 丙酸杆菌在培养阳性的翻修肩关节内分布不均,标本数量和来源对培养结果有重大影响。
  • 未发现支持定义真性感染的有用阈值。

研究设计与样本

  • 纳入137例翻修肩关节置换术,每例至少提交4份标本培养且至少1份丙酸杆菌阳性。
  • 采用标准微生物学流程为每份标本生长量赋予半定量标本丙酸值(0.1、1、2、3或4)。
  • 每肩各标本丙酸值之和定义为肩丙酸评分,除以标本总数计算平均肩丙酸评分。

主要发现

  • 每肩各部位阳性标本数量为1至6份,阳性百分比为14%至100%。
  • 培养阳性肩关节中平均43%(中位数50%)的标本无生长。
  • 液体培养阳性率32.6%,软组织培养66.5%,植入物标本培养55.6%。
  • 液体标本平均标本丙酸值0.35±0.89显著低于软组织0.92±1.50和植入物0.66±0.90(p<0.001)。
  • 男性肩丙酸评分3.56±3.74显著高于女性1.22±3.11(p<0.001),男性平均肩丙酸评分0.53±0.51显著高于女性0.19±0.43(p<0.001)。

关键数值与推荐

  • 标本丙酸值半定量赋值为0.1、1、2、3或4。
  • 肩丙酸评分为每肩各标本丙酸值之和,平均肩丙酸评分为肩丙酸评分除以标本总数。
  • 诊断证据等级为III级。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Propionibacterium is commonly recovered from explants or surrounding tissues in revision shoulder arthroplasty. Rather than attempting to differentiate a true infection from a false-positive result on the basis of the number of positive cultures, we characterized the amount of these bacteria in each specimen and shoulder. METHODS: The study included 137 revision shoulder arthroplasties from which a minimum of 4 specimens had been submitted for culture and at least 1 was positive for Propionibacterium. Standard microbiology procedures were used to assign a semiquantitative value (0.1, 1, 2, 3, or 4), called the Specimen Propi Value, to the amount of growth in each specimen. The sum of the Specimen Propi Values for each shoulder was defined as the Shoulder Propi Score, which was then divided by the total number of specimens to calculate the Average Shoulder Propi Score. RESULTS: The number and percentage of positive specimen-specific cultures (of material obtained from the stem explant, head explant, glenoid explant, humeral membrane, collar membrane, other soft tissue, fluid, or other) per shoulder ranged from 1 to 6 and 14% to 100%. A high percentage of specimens (mean, 43%; median, 50%) from the culture-positive shoulders showed no growth. Only 32.6% of the fluid cultures were positive in comparison with 66.5% of the soft-tissue cultures and 55.6% of the cultures of explant specimens. The average Specimen Propi Value (and standard deviation) for fluid specimens (0.35 ± 0.89) was significantly lower than those for the soft-tissue (0.92 ± 1.50) and explant (0.66 ± 0.90) specimens (p < 0.001). The Shoulder Propi Score was significantly higher in men (3.56 ± 3.74) than in women (1.22 ± 3.11) (p < 0.001). Similarly, men had a significantly higher Average Shoulder Propi Score (0.53 ± 0.51) than women (0.19 ± 0.43) (p < 0.001). CONCLUSIONS: This investigation suggests that Propionibacterium is unevenly distributed within culture-positive revised shoulders. As a result, the specimen number and source (explant, soft tissue, or fluid) have major influences on the culture results for a revised shoulder arthroplasty. We found no evidence that suggested useful threshold values for defining a true infection. LEVEL OF EVIDENCE: Diagnostic Level III. See Instructions for Authors for a complete description of levels of evidence.

来源:J Bone Joint Surg Am,查看原文。版权归原作者所有。

引用

  1. Ahsan ZS, Somerson JS, Matsen FA, et al. Characterizing the Propionibacterium Load in Revision Shoulder Arthroplasty: A Study of 137 Culture-Positive Cases. J Bone Joint Surg Am. 2017. PMID: 28099305. doi:10.2106/JBJS.16.00422

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。