骨蜡可有效减少全膝关节置换术后失血
一项前瞻性随机对照研究纳入100例初次单侧骨水泥型全膝关节置换术患者,比较骨蜡组(2.5 g骨蜡涂于假体周围裸露骨及钉孔)与电凝止血对照组的失血情况。结果显示骨蜡组术后24小时和72小时血红蛋白下降幅度及72小时总失血量均低于对照组,且3个月随访无骨蜡相关不良事件。
要点
- 骨蜡组术后24小时血红蛋白下降1.6±0.9 g/dL,对照组2.1±1.1 g/dL(P=.021)。
- 骨蜡组术后72小时总失血量987.9 mL,对照组1183.5 mL(P=.017)。
- 术后3个月随访未发现与骨蜡使用相关的不良事件。
核心结论
- 全膝关节置换术中应用骨蜡安全且有效,可减少总失血量并维持较高血红蛋白水平。
研究设计与样本
- 前瞻性随机对照研究,纳入100例初次单侧骨水泥型全膝关节置换术患者,于2014年3月至2014年6月在一家三级中心开展。
主要发现
- 骨蜡组术后24小时血清血红蛋白下降1.6±0.9 g/dL,对照组下降2.1±1.1 g/dL(P=.021)。
- 骨蜡组术后72小时血清血红蛋白下降2.7±1.1 g/dL,对照组下降3.6±1.2 g/dL(P=.013)。
- 骨蜡组术后72小时总失血量为987.9 mL,对照组为1183.5 mL(P=.017)。
- 术后3个月随访未发现与骨蜡使用相关的不良事件。
关键数值与推荐
- 骨蜡组在松止血带前将2.5 g骨蜡涂抹于假体周围裸露骨及钉孔处,对照组仅采用电凝止血。
- 总失血量采用血红蛋白平衡法计算。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Total knee arthroplasty (TKA) is associated with major blood loss and blood transfusion is often required. This study aimed to evaluate the efficacy of bone wax in reducing blood loss and transfusion rates after TKA. METHODS: A prospective randomized controlled study that included 100 patients undergoing primary unilateral TKA with cement was conducted in a tertiary center between March 2014 and June 2014. The bone wax group received 2.5 g of bone wax, applied onto the uncovered bone around the prostheses and the nail holes before the tourniquet was released, whereas the control group had hemostasis achieved using electrocautery only. Total blood loss was calculated using the hemoglobin balance method. RESULTS: There were no demographic differences between the 2 groups. The preoperative serum hemoglobin levels were comparable between the 2 groups. The drop in serum hemoglobin levels at 24 h post-TKA was 1.6 ± 0.9 and 2.1 ± 1.1 g/dL in the bone wax and control groups respectively (P = .021), while the drop in serum hemoglobin levels at 72 h post-TKA was 2.7 ± 1.1 and 3.6 ± 1.2 g/dL respectively (P = .013). Total blood loss at 72 h post-TKA was 987.9 and 1183.5 mL for the bone wax and control groups respectively (P = .017). There was no adverse event associated with the use of bone wax at the 3-month follow-up. CONCLUSION: The application of bone wax in TKA was safe and effective for reducing total blood loss and maintaining higher hemoglobin levels.
引用
- Moo IH, Chen JYQ, Pagkaliwaga EH, et al. Bone Wax Is Effective in Reducing Blood Loss After Total Knee Arthroplasty. J Arthroplasty. 2016. PMID: 28089184. doi:10.1016/j.arth.2016.12.028
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。