文献速递关节外科

全羟基磷灰石涂层股骨柄全髋关节置换术:23-28年队列研究

Total Hip Arthroplasty With a Fully Hydroxyapatite-Coated Stem: A Cohort Study During 23-28 Years.
PubMed 文献 · J Arthroplasty · 2016-12-18

该队列研究随访1988-1993年接受323例初次全髋关节置换术的276例患者(平均年龄48岁),212例(255髋)随访超过20年。结果显示因晚期假体周围感染翻修3例、跌倒致假体周围骨折翻修1例、机械失败翻修2例;骨溶解与磨损显著相关,磨损与股骨头尺寸显著相关。作者结论认为全HA涂层钛柄压配植入可维持23-28年。

要点

  • 212例(255髋)随访超过20年,翻修共6例(感染3例、骨折1例、机械失败2例)。
  • 骨溶解与磨损显著相关,磨损与股骨头尺寸显著相关。
  • 作者结论认为全HA涂层钛柄压配植入可维持23-28年。

核心结论

  • 作者结论认为,全HA涂层钛柄压配植入可维持23-28年,骨改变证实股骨假体固定良好,无显著大腿痛。

研究设计与样本

  • 1988-1993年间共实施323例初次全髋关节置换术,涉及276例患者(189例女性),平均年龄48岁(15-79岁)。
  • 随访期间83例患者(88髋)死亡,18例患者未参加随访检查但电话访谈和对照检查无主要症状,最终212例患者(255髋)随访超过20年。

主要发现

  • 3例因晚期假体周围感染翻修,1例因跌倒致假体周围骨折翻修,2例股骨柄因机械失败翻修。
  • 骨溶解与磨损显著相关,磨损与股骨头尺寸显著相关。
  • 发现少量近端骨丢失和低发生率远端骨肥大。
  • 骨改变证实无症状患者股骨假体固定良好。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Long-term results of a hydroxyapatite (HA)-coated stem are sparse. We have followed a cohort of patients operated with a grit-blasted titanium stem designed for press-fit insertion and entirely plasma-sprayed with HA up to 28 years. METHODS: In the years 1988-1993, we performed 323 primary total hip arthroplasties in 276 patients (189 women). Their mean age was 48 (15-79) years. During the following years, 83 patients with 88 hips have died, and 18 patients did not attend the follow-up examination, but had no major symptoms according to telephone interviews and control examination. Thus, 212 patients (255 hips) were followed up for more than 20 years. RESULTS: Three patients were revised because of late periprosthetic infection, 1 because of a fall with periprosthetic fracture, and 2 stems were revised due to mechanical failure. Osteolysis was significantly associated with wear, and wear was significantly associated with the size of the femoral head. We found a small amount of proximal bone loss and a low incidence of distal hypertrophy of the bone. The bone changes confirmed a well-fixed femoral component in asymptomatic patients. CONCLUSION: Our findings indicate an essentially physiological weight distribution from the stem to the femoral bone with no significant thigh pain. The changes in the bone confirmed that the femoral component was well-fixed, and we conclude that a fully HA-coated titanium stem designed for press-fit insertion lasts for 23-28 years.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Reikerås O. Total Hip Arthroplasty With a Fully Hydroxyapatite-Coated Stem: A Cohort Study During 23-28 Years. J Arthroplasty. 2016. PMID: 28043711. doi:10.1016/j.arth.2016.12.008

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。