脊柱骨盆活动度与全髋关节置换术中髋臼假体位置
本研究为影像学研究,纳入160髋(151例患者),前瞻性行侧位脊柱骨盆髋关节X线片测量骨骼与假体参数,术中髋臼假体位置根据术前脊柱活动度确定。术后133髋(83.1%)的髋臼前倾角和骶骨髋臼角在正常范围内,145/160髋(90%)被认为无撞击风险;最高风险者为生物性或手术性脊柱融合患者,而术前存在危险脊柱失衡者通过正确的髋臼假体位置可达到安全。
要点
- 术后133髋(83.1%)的髋臼前倾角和骶骨髋臼角在正常范围内。
- 7髋(4.4%)存在病理性失衡,均为生物性或手术性脊柱融合髋。
- 145/160髋(90%)被认为无撞击风险,最高风险者为脊柱融合患者。
核心结论
- 160髋中145髋(90%)被认为无撞击风险。
- 最高风险患者为生物性或手术性脊柱融合者。
- 术前存在危险脊柱失衡的患者通过正确的髋臼假体位置可达到安全。
研究设计与样本
- 影像学研究,纳入160髋(151例患者),前瞻性行侧位脊柱骨盆髋关节X线片进行骨骼与假体测量。
- 术中髋臼假体位置根据术前脊柱活动度确定。
- 采用矢状面假体测量指标髋臼前倾角和骶骨髋臼角作为撞击风险的替代测量,并与术中髋臼假体角度进行比较。
主要发现
- 术后髋臼前倾角和骶骨髋臼角在133髋(83.1%)中处于正常范围。
- 7髋(4.4%)存在病理性失衡,均为生物性或手术性脊柱融合髋。
- 24髋中有23髋的术前危险脊柱失衡得到矫正。
- 160髋中145髋(90%)被认为无撞击风险。
关键数值与推荐
- 术后髋臼前倾角和骶骨髋臼角正常范围:133髋(83.1%)。
- 病理性失衡:7髋(4.4%),均为生物性或手术性脊柱融合髋。
- 术前危险脊柱失衡矫正:24髋中23髋。
- 无撞击风险:145/160髋(90%)。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
AIMS: Posterior tilt of the pelvis with sitting provides biological acetabular opening. Our goal was to study the post-operative interaction of skeletal mobility and sagittal acetabular component position. MATERIALS AND METHODS: This was a radiographic study of 160 hips (151 patients) who prospectively had lateral spinopelvic hip radiographs for skeletal and implant measurements. Intra-operative acetabular component position was determined according to the pre-operative spinal mobility. Sagittal implant measurements of ante-inclination and sacral acetabular angle were used as surrogate measurements for the risk of impingement, and intra-operative acetabular component angles were compared with these. RESULTS: Post-operatively, ante-inclination and sacral acetabular angles were within normal range in 133 hips (83.1%). A total of seven hips (4.4%) had pathological imbalance and were biologically or surgically fused hips. In all, 23 of 24 hips had pre-operative dangerous spinal imbalance corrected. CONCLUSIONS: In all, 145 of 160 hips (90%) were considered safe from impingement. Patients with highest risk are those with biological or surgical spinal fusion; patients with dangerous spinal imbalance can be safe with correct acetabular component position. The clinical relevance of the study is that it correlates acetabular component position to spinal pelvic mobility which provides guidelines for total hip arthroplasty. Cite this article: Bone Joint J 2017;99-B(1 Supple A):37-45.
引用
- Stefl M, Lundergan W, Heckmann N, et al. Spinopelvic mobility and acetabular component position for total hip arthroplasty. Bone Joint J. 2017. PMID: 28042117. doi:10.1302/0301-620X.99B1.BJJ-2016-0415.R1
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。