自体膝关节穿刺后培养假阳性:真或假
本研究纳入200例因退行性骨关节炎行全膝关节置换术的患者(200膝),术前无菌条件下行膝关节穿刺,液体送细胞计数和培养。166例有足够液体送检的患者中,无假阳性培养(0/166,0%)。作者认为,在无假体的膝关节,规范无菌穿刺的培养阳性应强烈提示细菌性化脓性关节炎。
要点
- 无假体膝行全膝关节置换术前无菌穿刺,166例中假阳性培养为0例(0%)。
- 32例(16%)因干抽被排除,1例未穿刺,1例标本意外丢弃。
- 作者认为培养阳性应强烈怀疑细菌性化脓性关节炎。
核心结论
- 在无假体的膝关节,规范无菌技术下穿刺培养不应受常见污染菌种影响,培养阳性应强烈提示细菌性化脓性关节炎。
研究设计与样本
- 研究纳入200例诊断为退行性骨关节炎并接受全膝关节置换术的患者,共200膝,术前无菌条件下行膝关节穿刺,液体送细胞计数和培养。
- 32例(16%)因干抽被排除,1例入组但未行膝关节穿刺,另1例标本意外丢弃,最终166膝有培养结果。
主要发现
- 166例有培养结果的自体膝关节穿刺中,假阳性培养为0例(0/166,0%)。
关键数值与推荐
- 假阳性培养频率为0/166(0%)。
临床怎么用
- 作者认为,对无假体的膝关节行无菌穿刺,培养阳性应强烈怀疑细菌性化脓性关节炎。
- 作者建议未来研究应纳入更多标本以及既往行全膝关节置换术的膝关节,以进一步明确两类人群膝关节穿刺的假阳性培养率。
局限性
- 32例(16%)因干抽被排除,1例入组但未行膝关节穿刺,另1例标本意外丢弃。
- 作者建议未来研究应纳入更多标本以及既往行全膝关节置换术的膝关节,以进一步明确两类人群膝关节穿刺的假阳性培养率。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Synovial fluid aspiration is a routine practice used by most orthopaedic surgeons to aid in the diagnosis of joint infection. In patients for whom there is a low pretest probability of infection, a positive culture-particularly if it is a broth-only culture-may be considered a contaminant, especially if the bacterial species are skin pathogens. To our knowledge no study has evaluated the incidence of contamination of aspirations from the native knee. QUESTIONS/PURPOSES: What is the frequency of false-positive cultures among knee aspirations of the native knee? METHODS: Two hundred patients, with a total of 200 knees, with the diagnosis of degenerative osteoarthritis undergoing a total knee arthroplasty (TKA) were identified for this study. None of these patients had symptoms, signs, or laboratory studies to suggest the presence of joint infection; a positive culture in this population therefore would be considered contaminated. Thirty-two (16%) patients were excluded secondary to a dry aspiration. One patient was enrolled in the study but did not have the knee aspirated and another patient's specimen was accidentally discarded. Each knee was aspirated under sterile conditions before performing the TKA. The fluid was sent for cell count and culture. If insufficient fluid was obtained for both cell count and culture, culture was performed rather than cell count. RESULTS: There were no false-positive cultures (zero of 166 [0%]) in aspirations of native knees. CONCLUSIONS: Our study would indicate that when done properly under sterile technique, cultures taken from knee arthrocentesis in patients without prosthetic joints should not be affected by perceived contaminant species. A positive specimen finding on culture should raise a strong suspicion of bacterial septic arthritis. Future studies should include more specimens as well as knees with prior TKA to help further identify the rate of false-positive cultures in knee arthrocentesis in both populations. LEVEL OF EVIDENCE: Level I, diagnostic study.
引用
- Jennings JM, Dennis DA, Kim RH, et al. False-positive Cultures After Native Knee Aspiration: True or False. Clin Orthop Relat Res. 2017. PMID: 27942968. doi:10.1007/s11999-016-5194-4
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。