腘绳肌腱前交叉韧带重建后临床与影像学结果:固定环与可调节环皮质悬吊装置的比较
这项回顾性队列研究(证据等级3)纳入117例接受腘绳肌腱前交叉韧带重建的患者,固定环组67例、可调节环组50例,最短随访2年。两组临床结果相似,但固定环组在轴移试验中稳定性显著更好;可调节环装置并未减少隧道扩大。
要点
- 固定环组与可调节环组术后临床结果和隧道扩大无显著差异。
- 固定环组轴移试验稳定性显著优于可调节环组(P = .018)。
- 可调节环装置未减少腘绳肌腱前交叉韧带重建后的隧道扩大。
核心结论
- 与固定环装置股骨固定相比,可调节环装置股骨固定显示相似的临床结果,但未减少腘绳肌腱前交叉韧带重建后的隧道扩大。
研究设计与样本
- 回顾性队列研究,证据等级3,单机构连续117例接受腘绳肌腱前交叉韧带重建的患者,固定环组67例、可调节环组50例,所有患者至少观察2年。
主要发现
- KT-1000关节动度计松弛度测量固定环组为1.5 ± 1.8 mm,可调节环组为1.2 ± 2.3 mm(P = .530)。
- 固定环组轴移试验稳定性显著优于可调节环组(P = .018)。
- 正位X线片上股骨隧道和胫骨隧道直径平均增加:固定环组分别为42.2% ± 15.9%和37.0% ± 17.8%,可调节环组分别为43.0% ± 15.4%和36.8% ± 18.2%。
- 侧位X线片上股骨隧道和胫骨隧道直径平均增加:固定环组分别为38.1% ± 14.8%和39.9% ± 13.8%,可调节环组分别为35.8% ± 12.2%和38.1% ± 21.0%。
- 两组术后股骨隧道和胫骨隧道扩大在正位X线片(P = .801和.951)和侧位X线片(P = .422和.621)上均无显著差异。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Few studies have compared clinical and radiological outcomes after hamstring anterior cruciate ligament (ACL) reconstruction with fixed-loop and adjustable-loop cortical suspension devices. Purpose/Hypothesis: The purpose of this retrospective study was to compare clinical outcomes and tunnel widening after hamstring ACL reconstructions with fixed- and adjustable-loop cortical suspension devices. The hypothesis was that compared with femoral graft fixation with the fixed-loop device, fixation with the adjustable-loop device would show similar clinical outcomes and would result in less tunnel widening after hamstring ACL reconstruction. STUDY DESIGN: Cohort study; Level of evidence, 3. METHODS: A total of 117 consecutive patients underwent hamstring ACL reconstruction at a single institution. The fixed-loop cortical suspension device was used in 67 patients, and the adjustable-loop cortical suspension device was used in 50 patients. All patients were observed for a minimum of 2 years. Postoperative knee laxity was evaluated with the Lachman test, pivot-shift test, and KT-1000 arthrometer. Functional evaluations were performed by use of the Lysholm score and the Tegner activity scale. On anteroposterior (AP) and lateral radiographs, the measured diameters of the femoral tunnel at 1 year after surgery were compared with the diameter of the reamer used at surgery. The measured diameters of the tibial tunnel at 1 year after surgery were compared with those taken immediately after surgery. RESULTS: The mean KT-1000 arthrometer laxity measurement was 1.5 ± 1.8 mm in the fixed-loop group and 1.2 ± 2.3 mm in the adjustable-loop group ( P = .530). Results of postoperative knee laxity evaluations and functional outcomes from both groups showed no statistically significant differences. However, the fixed-loop group showed significantly better stability in the pivot-shift test than did the adjustable-loop group ( P = .018). On AP radiographs, the mean diameter of the femoral and tibial tunnels increased by 42.2% ± 15.9% and 37.0% ± 17.8%, respectively, in the fixed-loop group and by 43.0% ± 15.4% and 36.8% ± 18.2% in the adjustable-loop group. On lateral radiographs, the mean diameter of the femoral and tibial tunnels increased by 38.1% ± 14.8% and 39.9% ± 13.8%, respectively, in the fixed-loop group and by 35.8% ± 12.2% and 38.1% ± 21.0% in the adjustable-loop group. No significant differences were found between the 2 groups in postoperative femoral and tibial tunnel widening on AP radiographs ( P = .801 and .951, respectively) or lateral radiographs ( P = .422 and .621, respectively). CONCLUSION: Compared with femoral fixation by use of the fixed-loop device, femoral fixation by use of the adjustable-loop device showed similar clinical outcomes but did not reduce tunnel widening after hamstring ACL reconstructions.
引用
- Choi NH, Yang BS, Victoroff BN, et al. Clinical and Radiological Outcomes After Hamstring Anterior Cruciate Ligament Reconstructions: Comparison Between Fixed-Loop and Adjustable-Loop Cortical Suspension Devices. Am J Sports Med. 2016. PMID: 27881383. doi:10.1177/0363546516674183
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。