一种经效验的替代计算机断层扫描的单视图放射学股骨前倾角测量方法:方法比较研究
本研究前瞻性纳入65例患者共105侧肢体,采用改良Budin位X线片与CT测量股骨前倾角(FA),以Pearson相关、配对样本t检验和Bland-Altman图评估一致性。全组Bland-Altman分析显示固定偏倚(平均偏倚-0.8°,95%CI -1.4°至-0.2°),放射学方法低估FA;各亚组相关极佳(r=0.97,P<.001),配对t检验无显著差异,偏倚均在0.5°以内。结论认为改良Budin位放射学测量FA是有效可靠的技术。
要点
- 全肢体Bland-Altman分析显示放射学方法较CT低估股骨前倾角,平均偏倚-0.8°(95%CI -1.4°至-0.2°)。
- 所有亚组(FA<35°、<30°、<25°)CT与放射学测量相关极佳(r=0.97,P<.001)。
- 配对样本t检验显示各亚组两种方法间无显著差异,偏倚均在0.5°以内。
核心结论
- 采用改良Budin位放射学测量股骨前倾角是有效且可靠的技术。
研究设计与样本
- 前瞻性方法比较研究,纳入65例患者共105侧肢体,获取CT扫描与改良Budin位X线片测量原生股骨前倾角。
- 改良Budin位方案为膝关节屈曲90°、髋关节屈曲90°并外展30°。
- 按CT测得的股骨前倾角以5°间隔分组,包括全肢体组、FA<35°组、FA<30°组和FA<25°组。
- 采用Pearson相关分析、配对样本t检验和Bland-Altman图评估方法间相关性与一致性。
主要发现
- 全肢体Bland-Altman分析显示固定偏倚(平均偏倚-0.8°,95%CI -1.4°至-0.2°),放射学方法低估股骨前倾角。
- 所有亚组中CT与放射学测量相关极佳(r=0.97,P<.001)。
- 配对样本t检验显示所有亚组两种方法间无显著差异。
- 所有亚组中两种方法偏倚均在0.5°以内,亚组分析中无固定偏倚,即无系统差异。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Although preoperative templating in total hip arthroplasty is helpful to ensure appropriate component position, there is no single-view radiographic method to determine femoral anteversion (FA) preoperatively. The aim of the present study was to validate the use of radiographic measurement of FA using a modified Budin view. METHODS: This prospective study reports on 105 limbs from 65 patients. Computed tomography (CT) scans and radiographs were obtained to measure native FA. Radiographs were obtained using the modified Budin protocol with 90° flexion at the knee and 90° flexion and 30° abduction at the hip. Pearson correlation analyses, paired-samples t-test, and Bland-Altman plots were performed to assess correlation and agreement between methods. Data were grouped into subsets based on CT-derived FA in 5° intervals. Groups included all limbs, FA < 35°, FA < 30°, and FA < 25°. RESULTS: For all limbs, Bland-Altman analysis revealed a fixed bias (mean bias, -0.8°; 95% confidence interval, -1.4° to -0.2°) and showed that radiographic methods underestimated FA. Subset analyses were performed and revealed excellent correlation between CT and radiographic measurements for all subgroups (r = 0.97, P < .001). Paired-samples t-tests revealed no significant difference between methodologies for any of the subgroups. Radiographic and CT methods showed excellent agreement, and the bias between methods was within 0.5° for all subgroups. There was no fixed bias and thus no systematic difference in methods within any of the subgroup analyses. CONCLUSION: Radiographic measurement of FA using a modified Budin view is a valid and reliable technique.
引用
- Boissonneault AR, Hiranaka T, Roberson JR, et al. A Validated Single-View Radiographic Alternative to Computed Tomography for the Measurement of Femoral Anteversion: A Method-Comparison Study. J Arthroplasty. 2016. PMID: 27816368. doi:10.1016/j.arth.2016.09.016
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。