文献速递关节外科

评估内收肌结节作为可靠标志确定中国人群膝关节关节线的准确性研究

A Study to Assess the Accuracy of Adductor Tubercle as a Reliable Landmark Used to Determine the Joint Line of the Knee in a Chinese Population.
PubMed 文献 · J Arthroplasty · 2016-10-11

本研究基于50例膝关节X线片建立测量方案,测量股骨宽度(FW)与内收肌结节至关节线距离(ATJL),并在20例膝关节MRI上验证比值公式。结果显示FW与ATJL线性相关(r²=0.7201),ATJL/FW平均比值0.560±0.03,男女间无统计学差异,MRI验证全部病例位于4 mm误差范围内。结论认为内收肌结节可作为确定膝关节关节线的可靠标志。

要点

  • FW与ATJL线性相关(r²=0.7201),优于FD与ATJL的相关性(r²=0.3918)。
  • ATJL/FW平均比值0.560±0.03,男女间无统计学差异。
  • MRI验证中全部病例位于4 mm误差范围内。

核心结论

  • 内收肌结节可作为确定膝关节关节线位置的可靠标志,利用FW计算ATJL的公式可应用,使术中识别和判断更容易。

研究设计与样本

  • 建立50例膝关节X线片的标准化测量方案,在正位片测量股骨宽度(FW)和内收肌结节至关节线距离(ATJL),在真侧位片测量股骨直径(FD),用线性回归分析计算FW和FD与ATJL的个体比值,并评估观察者内和观察者间信度;另用20例膝关节磁共振图像记录FW和ATJL以检验所计算比值的准确性。

主要发现

  • 这些参数在性别间存在显著差异。
  • FW与ATJL之间存在线性相关(r²=0.7201),比FD与ATJL的相关性(r²=0.3918)更可靠。
  • ATJL和FW的观察者间重复性优于FD。
  • ATJL/FW的平均比值为0.560±0.03,男女之间无统计学差异。
  • 将比值公式应用于膝关节磁共振成像测量数据后,全部病例均显示可靠性,100%病例位于4 mm误差范围内。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Restoring the joint line (JL) is a key element of performing joint arthroplasty, which is a challenging proposition during revision surgeries. We investigated the accuracy of 2 different methods of identifying the JL using the adductor tubercle (AT) as the reference landmark. METHODS: Standardized protocols for measurements from 50 knee radiographs were established. Femoral width (FW) and the distance from the AT to the JL (ATJL) were measured on anteroposterior radiographs, and the femoral diameter (FD) was measured on true lateral views. The individual ratio of FW and FD to ATJL was calculated using linear regression analysis. Intraobserver and interobserver reliability was assessed. In order to test the accuracy of the ratio calculated, we also recorded the FW and ATJL of 20 additional knees by magnetic resonance images. RESULTS: There are significant differences between genders with these parameters. A linear correlation was found between FW and ATJL (r2 = 0.7201), which was more reliable than the correlation between FD and ATJL (r2 = 0.3918). Interobserver repeatability was better for ATJL and FW than for FD. The mean ratio of ATJL/FW was 0.560 ± 0.03, and there was no statistical difference between men and women. After using this ratio formulas in those data measured from knee magnetic resonance imaging, all cases revealed reliability with 100% cases lying in a 4-mm error margin. CONCLUSION: The AT can be used as a reliable landmark to determine the knee JL position, and the formulas for calculating the ATJL with FW can be applied, making intraoperative identification and judgment easier.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Xiao J, Wang S, Chen W, et al. A Study to Assess the Accuracy of Adductor Tubercle as a Reliable Landmark Used to Determine the Joint Line of the Knee in a Chinese Population. J Arthroplasty. 2016. PMID: 27836580. doi:10.1016/j.arth.2016.10.002

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。