文献速递关节外科创伤骨科

全髋关节置换术中髋臼假体周围隐匿性骨折频繁发生

Periprosthetic Occult Fractures of the Acetabulum Occur Frequently During Primary THA.
PubMed 文献 · Clin Orthop Relat Res · 2016-10-31

本研究回顾性分析406例(486髋)初次全髋关节置换术(THA)患者术前及术后CT,评估髋臼隐匿性骨折的发生率、位置及危险因素。隐匿性骨折发生率为8.4%,最常位于髋臼上外侧壁;使用外周自锁型髋臼杯与隐匿性骨折风险增加相关(OR 2.6,95%CI 1.2-5.6,p<0.05)。所有隐匿性骨折患者末次随访时均显示骨长入固定,未接受额外手术干预。

要点

  • 初次THA中髋臼隐匿性骨折发生率为8.4%,术中可见骨折另占0.4%。
  • 隐匿性骨折最常位于髋臼上外侧壁。
  • 使用外周自锁型髋臼杯与隐匿性骨折风险增加相关(OR 2.6,95%CI 1.2-5.6,p<0.05)。

核心结论

  • 初次THA打压植骨置入假体时髋臼假体周围隐匿性骨折可能相对频繁发生。
  • 使用外周自锁型假体与更高的骨折发生率相关。
  • 若术中已确认髋臼杯固定牢靠,常规术后平片未发现的髋臼隐匿性骨折可忽略。

研究设计与样本

  • 回顾性研究,纳入2004年至2013年本研究所494例患者共585例初次THA(非骨水泥型或混合型),均有术前和术后DICOM CT。
  • 排除既往骨盆截骨、创伤和感染史者(88例/99髋),最终406例(男102例,女304例;486髋)纳入分析。
  • 患者平均年龄60±11岁,平均BMI 23±4 kg/m2;髋臼假体周围骨折患者平均随访58±28个月(范围12-131个月)。

主要发现

  • 隐匿性骨折发生于41髋(8.4%);术中可见的髋臼假体周围骨折另有2髋(0.4%)。
  • 隐匿性骨折最常位于髋臼上外侧壁。
  • 控制相关混杂变量后,仅使用外周自锁型髋臼杯与隐匿性骨折风险增加相关(与半球形杯相比,OR 2.6;95%CI 1.2-5.6;p<0.05)。
  • 所有隐匿性骨折患者末次随访时均显示骨长入固定,未接受额外手术干预。

关键数值与推荐

  • 隐匿性骨折定义为常规术后X线片未发现的骨折。
  • 术中发现的骨折接受附加髋臼顶螺钉固定和3周非负重治疗。
  • 本组隐匿性骨折患者未接受额外治疗,因术中已确认髋臼杯固定牢靠。

临床怎么用

  • 术中确认髋臼杯固定牢靠时,常规术后平片未发现的髋臼隐匿性骨折可忽略。
  • 使用外周自锁型髋臼杯时需注意隐匿性骨折风险可能增加。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Periprosthetic fractures of the acetabulum occurring during primary THA are rare. Periprosthetic occult fractures are defined as those not identified by the surgeon during the procedure which might be missed on a routine postoperative radiograph. However, it is unclear how frequently these fractures occur and whether their presence affects functional recovery. QUESTIONS/PURPOSES: In this study, using routine CT scans that were obtained as part of another primary hip arthroplasty study protocol, we retrospectively assessed (1) the prevalence of occult fractures of the acetabulum occurring during primary THA, (2) the location of occult fractures of the acetabulum during THA, and (3) risk factors contributing to such occult fractures. METHODS: Between 2004 and 2013, our institute performed 585 primary THAs (cementless or hybrid) in 494 patients with DICOM pre- and postoperative CT; during the period in question, all patients undergoing THA underwent CT before and after surgery. Preoperative CT images were taken as part of a CT-based three-dimensional templating software and navigation system. Postoperative CT images were taken an average of 1 week after surgery as part of a different protocol to evaluate cup position, restoration of leg length and offset, volume of postoperative hematoma to assess anticoagulation effects after THA, and fractures that were not found on routine postoperative radiographs (which we defined as occult fractures). Patients with a history of prior pelvic osteotomy, trauma, and infection were excluded (88 patients/99 hips); 406 patients (102 males and 304 females; 486 hips) form the basis of this report. The mean age of the patients was 60 ± 11 years, with a mean BMI of 23 ± 4 kg/m2. The mean followup of the patients with periprosthetic fracture of the acetabulum was 58 ± 28 months (range, 12-131 months). Potential risk factors for occult acetabular fracture including age, sex, BMI, preoperative diagnosis, additional dome screw fixation, composition and size of each cup, and acetabular design were examined in multivariate analysis. Acetabular component designs were categorized as true hemispheric, peripheral self-locking, and elliptical; during the period in question the indications for each cup design were based on the brand of stem used. Comparison between preoperative and postoperative CT images was done to detect the fractures. Patients with fractures identified during surgery were treated with additional dome screw fixation and a 3-week period of nonweightbearing. Patients with occult fractures in this series did not receive additional treatment as we had confirmed secure fixation of the cup during surgery. RESULTS: Occult fractures occurred in 41 hips (8.4%); periprosthetic fractures of the acetabulum were seen during surgery in an additional two hips (0.4%). The superolateral wall was the most frequent location for occult fractures of the acetabulum. After controlling for relevant confounding variables, only the use of peripheral self-locking cups was associated with an increased risk of occult fracture (odds ratio [OR], 2.6 compared with hemispheric cups; 95% CI, 1.2-5.6; p < 0.05). All patients with occult fractures showed bone ingrowth fixation at the final followup, without any additional surgical intervention. CONCLUSIONS: Periprosthetic occult fractures of the acetabulum may occur relatively frequently during press-fit impaction. We observed a higher rate of fractures associated with the use of peripheral self-locking components. Occult acetabular fractures not detected on routine postoperative plain films may be ignored if secure fixation of the cup has been confirmed during the operation. LEVEL OF EVIDENCE: Level III, therapeutic study.

来源:Clin Orthop Relat Res,查看原文。版权归原作者所有。

引用

  1. Hasegawa K, Kabata T, Kajino Y, et al. Periprosthetic Occult Fractures of the Acetabulum Occur Frequently During Primary THA. Clin Orthop Relat Res. 2016. PMID: 27800574. doi:10.1007/s11999-016-5138-z

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。