使用新方法确定前倾角时髋臼假体位置的准确性
本研究将100例连续直接前入路全髋关节置换术按性别、体重指数和年龄与100例后入路全髋关节置换术配对,比较髋臼假体位置、下肢长度差异和髋关节偏移。前入路组髋臼前倾角平均18.4°,后入路组23.6°;前入路组100%假体位于安全区,后入路组81%位于安全区(P<.001)。两组下肢长度差异无差异(P=.259),髋关节偏移在术侧与对侧间也无差异。
要点
- 前入路组髋臼假体100%位于安全区,后入路组81%位于安全区(P<.001)。
- 前入路组髋臼前倾角平均18.4°(范围11°-26°),后入路组23.6°(范围8°-38°)。
- 两组下肢长度差异无差异(P=.259),髋关节偏移术侧与对侧无差异。
核心结论
- 术中透视辅助直接前入路与改善的髋臼假体位置相关,但在恢复髋关节偏移或下肢长度方面未显示获益。
研究设计与样本
- 将100例连续直接前入路全髋关节置换术按性别、体重指数和年龄与100例后入路初次全髋关节置换术配对,分析术后X线片确定髋臼杯外倾角、前倾角、下肢长度差异和髋关节偏移。
主要发现
- 前入路组髋臼杯外倾角平均40.8°(范围33°-48°),后入路组45.1°(范围33°-55°)。
- 使用新的C臂倾斜平面技术,前入路组髋臼前倾角平均18.4°(范围11°-26°),后入路组23.6°(范围8°-38°)。
- 前入路组100%髋臼杯位于安全区,后入路组81%位于安全区(P<.001)。
- 前入路组术侧与对侧髋关节偏移无差异(P=.074),后入路组也无差异(P=.919)。
- 两种入路的下肢长度差异无差异(P=.259)。
关键数值与推荐
- 前入路组100%髋臼杯位于安全区,后入路组81%位于安全区(P<.001)。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: This study compares the differences in acetabular component position, leg length discrepancy, and hip offset between the anterior and posterior approach. A novel method is applied to determine the acetabular anteversion using the C-arm tilt angle for the anterior approach. METHODS: Hundred consecutive anterior total hip arthroplasties were matched according to gender, body mass index, and age to a cohort of 100 primary total hip arthroplasties operated on through a posterior approach. Postoperative radiographs were analyzed to determine cup inclination, cup anteversion, leg length discrepancy, and hip offset. RESULTS: The mean inclination was 40.8° (range 33°-48°) and 45.1° (range 33°-55°) for the anterior and posterior approach, respectively. Using the new C-arm tilt plane technique, an average acetabular anteversion of 18.4° (range 11°-26°) was achieved with the anterior approach compared with 23.6° (range 8°-38°) with the posterior approach. Hundred percent cups in the anterior group and 81% in the posterior group fell within the safe zone (P < .001). There was no difference in the overall hip offset between the operated side and the contralateral side for the anterior (P = .074) and posterior (P = .919) group. There was no difference in leg length discrepancy between the 2 approaches (P = .259). CONCLUSION: Intraoperative fluoroscopy-assisted direct anterior approach was associated with improved acetabular component positioning. However, no benefit was shown with regards to restoration of hip offset or leg length.
引用
- Boettner F, Zingg M, Emara AK, et al. The Accuracy of Acetabular Component Position Using a Novel Method to Determine Anteversion. J Arthroplasty. 2016. PMID: 27839959. doi:10.1016/j.arth.2016.10.004
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。