手术改变维生素D状态参数及其他实验室检查结果
研究以40例择期全髋关节置换患者作为髋部骨折患者的替代人群,发现术后第一天总25-羟维生素D、维生素D结合蛋白、钙、肌酐、碱性磷酸酶和白蛋白下降8-22%,游离25-羟维生素D和血红蛋白分别下降8%和15%,尿维生素D结合蛋白/肌酐比值升高32%;以25-羟维生素D<30 ng/mL为阈值,维生素D不足患病率从术前38%升至术后第一天68%,所有指标在术后6周恢复基线。
要点
- 择期全髋关节置换术后第一天多种骨健康相关实验室指标下降8-22%。
- 以25-羟维生素D<30 ng/mL为阈值,维生素D不足患病率从术前38%升至术后第一天68%。
- 术后即刻检测不能可靠反映基线状态,所有指标在术后6周恢复基线。
核心结论
- 择期全髋关节置换术后即刻实验室值降低,此时检测不能准确反映基线状态,可能导致维生素D不足估计偏高、干预不当和医疗资源分配错误。
研究设计与样本
- 研究纳入40例择期全髋关节置换患者作为髋部骨折患者的替代人群,在术前2周、麻醉诱导前、术后第一天和术后6周采集血液和尿液。
主要发现
- 术后第一天总25-羟维生素D、维生素D结合蛋白、钙、肌酐、碱性磷酸酶和白蛋白下降8-22%(p < 0.0001)。
- 术后第一天游离25-羟维生素D下降8%(p < 0.01),血红蛋白下降15%(p < 0.01),尿维生素D结合蛋白/肌酐比值升高32%(p < 0.01)。
- 以25-羟维生素D<30 ng/mL为阈值,维生素D不足患病率从术前38%升至术后第一天68%(p < 0.001)。
- 所有实验室值在术后6周恢复基线。
关键数值与推荐
- 40例志愿者(28名女性,12名男性)平均年龄65.7 [8.7]岁。
- 实验室结果从术前2周至手术当天保持稳定。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
UNLABELLED: Fracture liaison services often perform laboratory testing, but these results may be altered by surgery. In 40 hip arthroplasty patients, many laboratory parameters of bone health relevance were reduced by 8-22% on the first post-operative day. Laboratory results obtained in the immediate post-surgery interval do not reliably ascertain baseline status. INTRODUCTION: As secondary causes of osteoporosis are common, fracture liaison services often perform laboratory testing in the immediate post-fracture interval. We hypothesized that laboratory results obtained shortly after surgery may not accurately ascertain baseline status. If true, such alterations might confound subsequent fracture prevention efforts. METHODS: Patients undergoing elective total hip arthroplasty were studied as a surrogate for hip fracture patients. Blood and urine were obtained 2 weeks before surgery, before anesthetic induction, on post-operative day one, and 6 weeks after surgery. Serum total and free 25-hydroxyvitamin D (25(OH)D), vitamin D-binding protein (DBP), calcium, creatinine, albumin (Alb), alkaline phosphatase (ALP), plasma hemoglobin (Hgb) and urinary DBP/creatinine ratio (UDBP/Cr) were measured. RESULTS: Forty volunteers (28 women; 12 men) with mean age of 65.7 [8.7] years were studied. Laboratory results were stable from 2 weeks before to the day of surgery. On the first day after surgery, total 25(OH)D, DBP, calcium, creatinine, ALP, and Alb declined 8-22% (p < 0.0001); free 25(OH)D and Hgb declined by 8 and 15% (p < 0.01), respectively; and UDBP/Cr increased 32% (p < 0.01). Using a 25(OH)D <30 ng/mL threshold, vitamin D inadequacy prevalence increased from 38% before surgery to 68% the day after (p < 0.001). All laboratory values returned to baseline at 6 weeks after surgery. CONCLUSIONS: Laboratory values are reduced immediately following elective total hip arthroplasty. Testing at that time does not accurately ascertain baseline status and may lead to elevated estimates of vitamin D inadequacy, incorrect interventions, and misallocation of healthcare resources.
引用
- Binkley N, Coursin D, Krueger D, et al. Surgery alters parameters of vitamin D status and other laboratory results. Osteoporos Int. 2016. PMID: 27826645. doi:10.1007/s00198-016-3819-9
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。