Medicare人群中初次全髋关节置换术后陶瓷轴承的结果

Outcomes of Ceramic Bearings After Primary Total Hip Arthroplasty in the Medicare Population.
PubMed 文献 · J Arthroplasty · 2016-09-28

本研究基于美国Medicare 100%全国行政医院索赔数据库,纳入2005年至2014年间接受初次全髋关节置换术的315,784例65岁以上老年患者,采用倾向性评分调整轴承类型选择偏倚,分析陶瓷轴承的感染、脱位、翻修或死亡结局。结果显示,与金属对聚乙烯(M-PE)轴承相比,陶瓷对聚乙烯(C-PE)轴承和陶瓷对陶瓷(COC)轴承的感染风险显著降低(C-PE HR:0.86,P=0.001;COC HR:0.74,P=0.01);C-PE队列的脱位风险(HR:0.81,P<0.001)和死亡风险(HR:0.92,P<0.001)也降低;两种陶瓷轴承的翻修风险与M-PE无显著差异,COC队列的脱位和死亡风险无显著差异。结论认为,在8-9年随访中,陶瓷轴承的总体翻修风险与M-PE相似,但感染风险更低,C-PE轴承还与较低的脱位和死亡风险相关。

要点

  • 在Medicare初次全髋关节置换患者中,陶瓷对聚乙烯和陶瓷对陶瓷轴承的感染风险显著低于金属对聚乙烯轴承。
  • 陶瓷对聚乙烯轴承的脱位风险和死亡风险显著低于金属对聚乙烯轴承。
  • 陶瓷对聚乙烯和陶瓷对陶瓷轴承的翻修风险与金属对聚乙烯轴承无显著差异。

核心结论

  • 在8-9年随访中,陶瓷轴承的总体翻修风险与金属对聚乙烯轴承相似,但陶瓷轴承治疗的Medicare初次全髋关节置换患者感染风险低于金属对聚乙烯轴承。
  • 陶瓷对聚乙烯轴承还与较低的脱位风险和死亡风险相关。

研究设计与样本

  • 回顾性分析美国Medicare 100%全国行政医院索赔数据库,纳入2005年至2014年间接受初次全髋关节置换术的315,784例65岁以上老年患者。
  • 采用倾向性评分调整初次手术时轴承类型选择的选择偏倚。

主要发现

  • 与金属对聚乙烯轴承相比,陶瓷对聚乙烯轴承的感染风险显著降低(HR:0.86,P=0.001),陶瓷对陶瓷轴承的感染风险也显著降低(HR:0.74,P=0.01)。
  • 陶瓷对聚乙烯队列的脱位风险(HR:0.81,P<0.001)和死亡风险(HR:0.92,P<0.001)均显著降低。
  • 陶瓷对聚乙烯和陶瓷对陶瓷队列的翻修风险与金属对聚乙烯相比均无显著差异。
  • 陶瓷对陶瓷队列的脱位风险和死亡风险与金属对聚乙烯相比均无显著差异。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The purpose of this study was to analyze the outcomes of ceramic bearings used in primary total hip arthroplasty (THA) in the Medicare population. METHODS: A total of 315,784 elderly Medicare patients (65+) who underwent primary THA between 2005 and 2014 were identified from the United States Medicare 100% national administrative hospital claims database. Outcomes of interest included infection, dislocation, revision, or mortality at any time point after primary surgery. Propensity scores were developed to adjust for selection bias in the choice of bearing type at index primary surgery. RESULTS: For primary THA patients treated with ceramic-on-polyethylene (C-PE) bearings and ceramic-on-ceramic (COC) bearings, there was significantly reduced risk of infection relative to metal-on-polyethylene (M-PE) bearings (C-PE hazard ratio [HR]: 0.86, P = .001; COC HR: 0.74, P = .01). For the C-PE cohort, we also observed reduced risk of dislocation (HR: 0.81, P < .001) and mortality (HR: 0.92, P < .001). There was no significant difference in risk of revision for either the C-PE or COC bearing cohorts when compared with M-PE. For the COC cohort, there was no significant difference in dislocation or mortality risk. CONCLUSION: As in previous studies, we found that ceramic bearings have similar overall revision risk as M-PE bearings in primary THA at 8-9 years of follow-up. The results indicate that, after adjusting for selection bias and various confounding patient-, surgeon-, and hospital-related factors, Medicare primary THA patients treated with ceramic bearings exhibit lower risk of infection than those treated with M-PE bearings. In addition, C-PE bearings were associated with lower risk of dislocation and mortality.

来源:J Arthroplasty,查看原文。版权归原作者所有。