文献速递关节外科创伤骨科

降钙素原与α-防御素诊断假体周围关节感染

Procalcitonin and α-Defensin for Diagnosis of Periprosthetic Joint Infections.
PubMed 文献 · J Arthroplasty · 2016-10-13

该Meta分析检索PubMed数据库,评估降钙素原(PCT)与α-防御素诊断假体周围关节感染(PJI)的准确性。α-防御素汇总敏感度0.96、特异度0.95、AUC 0.99;PCT汇总敏感度0.53、特异度0.92、AUC 0.76。作者认为滑液α-防御素在诊断PJI方面具有很大潜力。

要点

  • α-防御素诊断PJI的汇总敏感度0.96(95%CI 0.85-0.99)、特异度0.95(95%CI 0.89-0.98)。
  • PCT诊断PJI的汇总敏感度0.53(95%CI 0.24-0.80)、特异度0.92(95%CI 0.45-0.99)。
  • α-防御素汇总AUC 0.99(95%CI 0.97-0.99),PCT汇总AUC 0.76(95%CI 0.72-0.80)。

核心结论

  • 滑液α-防御素在诊断假体周围关节感染方面具有很大潜力。

研究设计与样本

  • 该研究为Meta分析,检索PubMed数据库中关于PCT或α-防御素诊断PJI价值的文献,计算敏感度、特异度、诊断比值比、汇总受试者工作特征曲线下面积(AUC)、阳性似然比和阴性似然比。
  • 原文未报告纳入文献数量与样本量。

主要发现

  • 检测PJI时,PCT与α-防御素的汇总敏感度分别为0.53(95%CI 0.24-0.80)和0.96(95%CI 0.85-0.99)。
  • 检测PJI时,PCT与α-防御素的汇总特异度分别为0.92(95%CI 0.45-0.99)和0.95(95%CI 0.89-0.98)。
  • 检测PJI时,PCT与α-防御素的汇总诊断比值比分别为13(95%CI 3-70)和496(95%CI 71-3456)。
  • PCT与α-防御素的汇总AUC分别为0.76(95%CI 0.72-0.80)和0.99(95%CI 0.97-0.99)。
  • PCT的阳性似然比为6.8(95%CI 1.0-48.1)、阴性似然比为0.51(95%CI 0.31-0.84);α-防御素的阳性似然比为19.6(95%CI 8.2-46.8)、阴性似然比为0.04(95%CI 0.01-0.17)。

关键数值与推荐

  • α-防御素诊断PJI的汇总敏感度0.96(95%CI 0.85-0.99)、特异度0.95(95%CI 0.89-0.98)、诊断比值比496(95%CI 71-3456)、AUC 0.99(95%CI 0.97-0.99)。
  • PCT诊断PJI的汇总敏感度0.53(95%CI 0.24-0.80)、特异度0.92(95%CI 0.45-0.99)、诊断比值比13(95%CI 3-70)、AUC 0.76(95%CI 0.72-0.80)。
  • α-防御素阳性似然比19.6(95%CI 8.2-46.8)、阴性似然比0.04(95%CI 0.01-0.17);PCT阳性似然比6.8(95%CI 1.0-48.1)、阴性似然比0.51(95%CI 0.31-0.84)。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Current methods to diagnose periprosthetic joint infection (PJI) before revision surgery have limited diagnostic accuracy. This meta-analysis was performed to estimate the accuracy of procalcitonin (PCT) and α-defensin for the diagnosis of PJI. METHODS: Articles on the diagnostic value of PCT or α-defensin for PJI diagnosis were searched in the PubMed database. Sensitivity, specificity, diagnostic odds ratio, the area under the curve of summary receiver operating characteristic curves (AUC), the positive likelihood ratio, and the negative likelihood ratio were calculated to evaluate the diagnostic ability of PCT and the α-defensin test for the diagnosis of PJI. RESULTS: The pooled sensitivities for detecting PJI using PCT and α-defensin were 0.53 (95% confidence interval [CI], 0.24-0.80) and 0.96 (95% CI, 0.85-0.99), respectively. The pooled specificities for detecting PJI using PCT and α-defensin were 0.92 (95% CI, 0.45-0.99) and 0.95 (95% CI, 0.89-0.98), respectively. The pooled diagnostic odds ratios for detecting PJI using PCT and α-defensin were 13 (95% CI, 3-70) and 496 (95% CI, 71-3456), respectively. The pooled AUCs for PCT and α-defensin were 0.76 (95% CI, 0.72-0.80) and 0.99 (95% CI, 0.97-0.99), respectively. The positive likelihood ratio and the negative likelihood ratio of PCT were 6.8 (95% CI, 1.0-48.1) and 0.51 (95% CI, 0.31-0.84), respectively, whereas those of α-defensin were 19.6 (95% CI, 8.2-46.8) and 0.04 (95% CI, 0.01-0.17), respectively. CONCLUSION: Synovial fluid α-defensin has a great potential to diagnose PJI.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Xie K, Qu X, Yan M, et al. Procalcitonin and α-Defensin for Diagnosis of Periprosthetic Joint Infections. J Arthroplasty. 2016. PMID: 27817992. doi:10.1016/j.arth.2016.10.001

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。