定制三翼髋臼组件在翻修全髋关节置换术中的生存率、临床结果与失败风险因素
本研究纳入56例非肿瘤性晚期髋臼骨缺损行翻修全髋关节置换术并使用定制三翼髋臼组件(CTAC)的患者,平均随访44.8个月。以无菌性松动为终点的CTAC生存率为94.3%(95%CI 82.6-98.2),功能评分显著改善,75.0%患者见影像学骨整合;既往髋部手术超过4次和坐骨骨溶解超过三分之二与影像学失败风险增加相关。
要点
- CTAC翻修THA中期生存率94.3%,无菌性松动翻修风险低。
- OHS中位数从术前12改善至末次随访36(P<0.001)。
- 既往髋部手术>4次和坐骨骨溶解>2/3与影像学失败风险增加相关。
核心结论
- CTAC重建晚期髋臼骨缺损具有优异的组件生存率、低无菌性松动风险、满意的功能结果和良好的影像学骨整合证据。
研究设计与样本
- 本研究为纳入56例非肿瘤性晚期髋臼骨缺损行翻修THA并使用CTAC的患者,平均随访44.8个月(范围13.7-63.4)。
主要发现
- 以CTAC因无菌性松动翻修为终点的生存率为94.3%(95%CI 82.6-98.2)。
- 共5例CTAC翻修:3例无菌性松动,2例假体周围感染。
- OHS中位数从术前12(IQR 10-14)改善至末次随访36(IQR 34-38)(P<0.001)。
- 末次随访HHS中位数64(IQR 60-72),UCLA中位数6(IQR 5-7),WOMAC中位数34(IQR 40-26),FJS中位数28(IQR 22-34)。
- 42例(75.0%)在骨-假体界面见影像学骨整合。
关键数值与推荐
- 影像学失败的风险因素包括既往髋部手术超过4次(P<0.001)和坐骨骨溶解超过三分之二(P<0.001)。
临床怎么用
- 对于非肿瘤性晚期髋臼骨缺损的翻修THA,CTAC可提供良好的中期生存率和功能结果。
- 术前应评估既往髋部手术次数和坐骨骨溶解范围,以识别影像学失败高风险患者。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: The objectives of this study were to assess survivorship, functional outcomes, radiographic osseointegration, complications, and risk factors for failure in revision total hip arthroplasty (THA) with custom triflange acetabular components (CTAC) at mid-term follow-up. METHODS: This study included 56 non-oncological patients who had advanced acetabular bone defects undergoing revision THAs using CTACs. Implant survivorship, the Oxford Hip Score (OHS), the Harris Hip Score (HHS), the University of California at Los Angeles (UCLA) activity score, the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), the Forgotten Joint (FJS) Score, plain radiographic evidence of osseointegration, and any complications were recorded at the most recent follow-up. The mean follow-up time was 44.8 months (range, 13.7 to 63.4). RESULTS: Survivorship of the CTAC was 94.3% (95% confidence interval (CI): 82.6 to 98.2) with CTAC revision for aseptic loosening as the end point. In total, five CTACs were revised: three for aseptic loosening and two for prosthetic joint infections. The median OHS improved from 12 (interquartile range(IQR), 10 to 14) preoperatively to 36 (IQR, 34 to 38) at final follow-up (P < 0.001). The median HHS was 64 (IQR, 60 to 72), the median UCLA score was 6 (IQR, 5 to 7), the median WOMAC score was 34 (IQR, 40 to 26), and the median FJS was 28 (IQR, 22 to 34) at final follow-up. Radiographic osseointegration at the bone-implant interface was observed in 42 patients (75.0%). Risk factors for radiographic failure included more than four previous hip operations (P < 0.001) and greater than two-thirds of ischial osteolysis (P < 0.001). DISCUSSION: The reconstruction of advanced acetabular bone defects with CTACs is associated with excellent component survivorship, low risk of aseptic loosening, satisfactory functional outcomes, and good radiographic evidence of osseointegration. Multiple previous hip operations and extensive ischial osteolysis were associated with increased risk of radiographic failure.
引用
- Kayani B, Drummond I, Merchant AA, et al. Custom Triflange Acetabular Components in Revision Total Hip Arthroplasty: Survivorship, Clinical Outcomes and Risk Factors for Failure. J Arthroplasty. 2026. PMID: 42918276. doi:10.1016/j.arth.2026.10.009
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。