文献速递关节外科

多偏移钛槽式柄与有限偏移钴铬柄在混合固定翻修全膝关节置换术中的比较:5至14年随访研究

Multiple-Offset Titanium Slot-Stems Versus Limited-Offset Cobalt-Chromium Stems in Hybrid-Fixation Revision Total Knee Arthroplasty: A Comparative Study With 5- to 14-Year Follow-up.
PubMed 文献 · J Arthroplasty · 2026-10-16

本研究回顾性比较了多偏移钛槽式柄(MOT)与有限偏移钴铬柄(LOC)在混合固定翻修全膝关节置换术(rTKA)中的临床和影像学结果及假体生存率。共纳入63例rTKA(MOT组39例,LOC组24例),平均随访8.6年(5至14年)。结果显示两组在患者报告结局和假体无菌性生存率上无显著差异,但MOT组在减少柄尖端疼痛、改善胫骨匹配、增加后髁偏移、改善关节线恢复和减少限制性衬垫使用方面具有优势。

要点

  • MOT组柄尖端疼痛发生率显著低于LOC组(0 vs 17%,P=0.043)。
  • MOT组内侧胫骨悬突更小(0.2±1.4 vs 2.2±2.5 mm,P=0.002),后髁偏移更大(33.0±4.7 vs 30.2±4.6 mm,P=0.020)。
  • MOT组关节线抬高更少(4.6±6.9 vs 9.4±8.4 mm,P=0.022),限制性衬垫使用率更低(13 vs 38%,P=0.025)。

核心结论

  • MOT系统与减少柄尖端疼痛、改善胫骨匹配、增加后髁偏移、改善关节线恢复和减少限制性衬垫使用相关。
  • 这些优势可能并未转化为患者报告结局或假体生存率的可测量改善。

研究设计与样本

  • 回顾性队列研究,纳入2012年至2020年接受rTKA且至少随访5年的患者,比较MOT与LOC系统。
  • 共评估63例rTKA(MOT组39例,LOC组24例),平均随访8.6年(范围5至14年)。

主要发现

  • mWOMAC、KSS和膝关节屈曲度在两组间无显著差异(P>0.05)。
  • 无菌性生存率相似(MOT组100% vs LOC组96%,P=0.200)。
  • MOT组柄尖端疼痛更低(0 vs 17%,P=0.043),内侧胫骨悬突更小(0.2±1.4 vs 2.2±2.5 mm,P=0.002),后髁偏移更大(33.0±4.7 vs 30.2±4.6 mm,P=0.020),关节线抬高更少(4.6±6.9 vs 9.4±8.4 mm,P=0.022),限制性衬垫使用更少(13 vs 38%,P=0.025)。
  • HKA对线在两组间相似。

关键数值与推荐

  • 无菌性生存率以无菌性翻修为终点,MOT组100%,LOC组96%(P=0.200)。
  • 柄尖端疼痛发生率MOT组0%,LOC组17%(P=0.043)。
  • 内侧胫骨悬突MOT组0.2±1.4 mm,LOC组2.2±2.5 mm(P=0.002)。
  • 后髁偏移MOT组33.0±4.7 mm,LOC组30.2±4.6 mm(P=0.020)。
  • 关节线抬高MOT组4.6±6.9 mm,LOC组9.4±8.4 mm(P=0.022);限制性衬垫使用率MOT组13%,LOC组38%(P=0.025)。

临床怎么用

  • 在混合固定rTKA中,MOT系统可能有助于减少柄尖端疼痛、改善胫骨匹配和关节线恢复,并降低限制性衬垫使用。
  • 尽管影像学和部分临床指标有优势,但需注意这些优势未显著改善患者报告结局或假体生存率。

局限性

  • 回顾性研究设计,样本量较小(共63例),可能存在选择偏倚。
  • 随访时间范围较宽(5至14年),且未报告随机化或盲法。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Multiple-offset titanium slot-stem (MOT) systems in revision total knee arthroplasty (rTKA) are designed to enhance component positioning, optimize gap balancing, and improve load transfer; however, clinical evidence remains limited. This study compared the clinical and radiographic outcomes of MOT and limited-offset cobalt-chromium stem (LOC) systems in hybrid-fixation rTKA and evaluated implant survivorship. METHODS: A retrospective cohort study included patients undergoing rTKA (2012 to 2020) with a minimum five-year follow-up. Patients received either MOT or LOC systems. Clinical outcomes included the modified Western Ontario and McMaster Universities Osteoarthritis Index (mWOMAC), the Knee Society Score (KSS), knee flexion, and stem-tip pain. Implant survivorship was analyzed using Kaplan-Meier methods with aseptic revision as the endpoint. Radiographic evaluation included component overhang, hip-knee-ankle (HKA) alignment, posterior condylar offset (PCO), joint-line level (JLL), and constrained liner use. There were 63 rTKAs (39 MOT and 24 LOC) evaluated at a mean follow-up of 8.6 years (range, five to 14). RESULTS: There were no significant differences observed in mWOMAC, KSS, or knee flexion (P > 0.05). Aseptic survivorship was also similar (100 MOT versus 96% LOC; P = 0.200). The MOT group showed lower stem-tip pain (0 versus 17%; P = 0.043), less medial tibial overhang (0.2 ± 1.4 versus 2.2 ± 2.5 mm; P = 0.002), greater PCO (33.0 ± 4.7 versus 30.2 ± 4.6 mm; P = 0.020), lower joint line elevation (4.6 ± 6.9 versus 9.4 ± 8.4 mm; P = 0.022), and less constrained liner use (13 versus 38%; P = 0.025). The HKA alignment was similar between groups. CONCLUSION: The MOT system was associated with reduced stem-tip pain, improved tibial fit, greater PCO, improved JLL restoration, and reduced constrained liner use compared with the LOC system. However, these advantages might not translate into measurable improvements in patient-reported outcomes or implant survivorship.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Boontanapibul K, Chankong K, Susrivaraput C, et al. Multiple-Offset Titanium Slot-Stems Versus Limited-Offset Cobalt-Chromium Stems in Hybrid-Fixation Revision Total Knee Arthroplasty: A Comparative Study With 5- to 14-Year Follow-up. J Arthroplasty. 2026. PMID: 42887706. doi:10.1016/j.arth.2026.10.006

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。