文献速递关节外科

旋转铰链式全膝关节置换在初次与翻修病例中的临床结果:回顾性队列研究

Clinical Outcomes of Rotating-Hinge Total Knee Arthroplasty in Primary and Revision Settings: A Retrospective Cohort Study.
PubMed 文献 · J Arthroplasty · 2026-10-07

该回顾性队列研究分析了110例患者(120膝)接受旋转铰链式全膝关节置换的临床结果,其中初次置换52膝、翻修68膝。两组功能评分均显著改善,5年假体生存率初次组98.1%、翻修组98.2%,log-rank P=0.58,支持在高复杂度膝关节中选择性使用现代旋转铰链假体。

要点

  • 初次与翻修旋转铰链TKA均获得显著功能改善,OKS改善超过最小临床重要差异的比例分别为94.2%和89.7%。
  • 5年假体生存率初次组98.1%(95%CI 87.1–99.7),翻修组98.2%(95%CI 88.2–99.8),组间无显著差异(P=0.58)。
  • 术中骨折发生率初次组9.6%(5/52)、翻修组5.9%(4/68),深部感染初次组1.9%(1/52)。

核心结论

  • 旋转铰链式TKA在初次和翻修场景中均带来有意义的功能和患者报告改善。
  • 并发症应结合严重畸形、不稳定、骨缺损和翻修复杂性解读,归因于基础病理而非假体限制性仍属推断。
  • 研究结果支持在高复杂度膝关节中选择性使用现代旋转铰链假体。

研究设计与样本

  • 回顾性队列研究,纳入2013年1月1日至2025年6月30日接受旋转铰链式TKA的110例患者(120膝),占同期4893例TKA的2.5%。
  • 预设两组:初次置换52膝,翻修68膝;初次组平均随访118.0个月(范围24.0–156.0),翻修组平均随访72.0个月(范围6.0–156.0)。
  • 功能评估采用膝关节学会功能评分(KSFS)和牛津膝关节评分(OKS),假体生存率采用Kaplan-Meier分析及log-rank比较。

主要发现

  • KSFS改善:初次组+35.1±3.4,翻修组+31.0±6.2;OKS改善:初次组+26.0±8.6,翻修组+24.7±9.4。
  • OKS改善超过5分最小临床重要差异的比例:初次组94.2%,翻修组89.7%。
  • 术中骨折:初次组5膝(9.6%),翻修组4膝(5.9%);深部感染:初次组1膝(1.9%)。
  • 符合失败定义者3膝:初次组1/52膝(深部感染,9个月),翻修组2/68膝(无菌性松动,46和74个月)。
  • Kaplan-Meier 5年生存率:初次组98.1%(95%CI 87.1–99.7),翻修组98.2%(95%CI 88.2–99.8),log-rank P=0.58。

关键数值与推荐

  • OKS最小临床重要差异阈值为5分,初次组94.2%、翻修组89.7%的膝关节改善超过该阈值。
  • 假体失败终点定义为任何再翻修或组件更换/取出。
  • 初次组所有病例随访至少24个月,翻修组无最低随访阈值。

临床怎么用

  • 对于无法通过低限制性假体实现稳定对线的复杂膝关节,可考虑选择性使用旋转铰链式TKA。
  • 初次和翻修病例中旋转铰链TKA均能获得显著功能改善,但需注意术中骨折和感染风险。
  • 并发症解释应结合患者基础畸形、不稳定、骨缺损和翻修复杂性,而非单纯归因于假体限制性。

局限性

  • 回顾性设计,无匹配对照组,无法将并发症归因于基础病理还是假体限制性。
  • 翻修组无最低随访阈值,随访时间范围较宽(6.0–156.0个月)。
  • 样本量较小(120膝),且为单中心研究,结果外推需谨慎。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Rotating-hinge implants provide the highest constraint in total knee arthroplasty (TKA) and are used when stable alignment cannot be achieved with less constrained designs. Outcomes are difficult to interpret because primary and revision cases are frequently combined. METHODS: We retrospectively reviewed 110 patients (120 knees) treated with rotating-hinge TKA from January 1, 2013, through June 30, 2025 (clinical follow-up updated through December 31, 2025), representing 120 of 4,893 (2.5%) of TKAs in this period. Cases were analyzed in two predefined groups: primary (52 knees) and revision (68 knees). There was no minimum follow-up threshold; all primary cases had at least 24 months. The mean follow-up was 118.0 months (range, 24.0 to 156.0) in the primary group and 72.0 months (range, 6.0 to 156.0) in the revision group. Function was assessed with the Knee Society Function Score (KSFS) and Oxford Knee Score (OKS). Implant survivorship (endpoint: any re-revision or component exchange/removal) was estimated by Kaplan-Meier analysis with log-rank comparisons. RESULTS: Both groups improved significantly: KSFS change +35.1 ± 3.4 (primary) and +31.0 ± 6.2 (revision); OKS change +26.0 ± 8.6 and +24.7 ± 9.4, exceeding the 5-point OKS minimal clinically important difference in 94.2 and 89.7%, respectively. Intraoperative fractures occurred in five primary (9.6%) and four revision (5.9%) knees; deep infection occurred in one primary knee (1.9%). There were three knees that met the failure definition: one of 52 primary knees (deep infection, nine months) and two of 68 revision knees (aseptic loosening, 46 and 74 months). The Kaplan-Meier 5-year survival was 98.1% (95% confidence interval [CI], 87.1 to 99.7) in primary knees and 98.2% (95% CI, 88.2 to 99.8) in revision knees; log-rank P = 0.58. CONCLUSION: Rotating-hinge TKA produced meaningful functional and patient-reported gains in both settings. Complications should be interpreted in the context of severe deformity, instability, bone loss, and revision complexity; attribution to underlying pathology, rather than implant constraint, remains inferential, as no matched comparator was available. These findings support selective use of modern rotating-hinge implants in high-complexity knees.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Jabalameli M, Bagherifard A, Askari A, et al. Clinical Outcomes of Rotating-Hinge Total Knee Arthroplasty in Primary and Revision Settings: A Retrospective Cohort Study. J Arthroplasty. 2026. PMID: 42843681. doi:10.1016/j.arth.2026.09.042

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。