文献速递关节外科

骨水泥髋关节置换术的手术结局:法国悖论技术 examination

Operative Outcomes of Cemented Hip Arthroplasty: An Examination of the French Paradox.
PubMed 文献 · J Arthroplasty · 2026-10-15

本研究回顾性分析2013至2020年单中心529例使用楔形锥度股骨柄的髋关节置换患者,其中227例采用法国悖论骨水泥技术,302例非骨水泥固定。结果显示两组90天再入院率、术中骨折及术后假体周围骨折无显著差异,骨水泥组下沉量显著更小(3.71 mm vs 5.16 mm,P < 0.0001)。结论认为法国悖论骨水泥技术下楔形锥度柄失败率低、下沉轻微。

要点

  • 法国悖论骨水泥技术用于楔形锥度股骨柄时失败率低、下沉轻微。
  • 骨水泥组平均下沉3.71 mm,显著小于非骨水泥组的5.16 mm(P < 0.0001)。
  • 两组90天再入院率、术中骨折及术后假体周围骨折无显著差异。

核心结论

  • 使用法国悖论骨水泥技术的楔形锥度股骨柄失败率低、下沉轻微,与文献报道相似。

研究设计与样本

  • 单中心回顾性队列研究,纳入2013至2020年使用单一楔形锥度股骨柄系统的髋关节置换患者,共529例,其中骨水泥固定227例、非骨水泥固定302例。

主要发现

  • 骨水泥组与非骨水泥组90天再入院率分别为0.18和0.16(卡方0.12,P = 0.71)。
  • 骨水泥组平均下沉3.71 mm,非骨水泥组5.16 mm(P < 0.0001)。
  • 骨水泥组术中骨折22例,非骨水泥组33例(卡方0.40,P = 0.53)。

关键数值与推荐

  • 骨水泥组90天再入院率0.18,非骨水泥组0.16(P = 0.71)。
  • 骨水泥组平均下沉3.71 mm,非骨水泥组5.16 mm(P < 0.0001)。
  • 骨水泥组术中骨折22例,非骨水泥组33例(P = 0.53)。

临床怎么用

  • 对于使用楔形锥度股骨柄行髋关节置换的患者,可考虑采用法国悖论骨水泥技术,其失败率低且下沉轻微。

局限性

  • 本研究为单中心回顾性队列研究,可能存在选择偏倚和混杂因素。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The benefits of cemented total hip arthroplasty continue to be recognized. Different methods of cement fixation exist, including the "French Paradox" which utilizes a line-to-line cement mantle. This study evaluated the postoperative outcomes of a cemented femoral stem using the "French Paradox" method. METHODS: In this retrospective cohort study, patients who underwent hip arthroplasty using a single femoral stem system with a wedge-taper design were identified using electronic medical records at a single academic institution from 2013 to 2020. The French Paradox technique was utilized for patients undergoing cement fixation. The outcomes reviewed were implant failure rates, including the mechanism of failure, subsidence (mm), evidence of aseptic loosening, intraoperative fractures, and bone cement implantation syndrome. Standard statistical analysis was performed for the 529 patients who met inclusion criteria; 227 were cemented and 302 were uncemented stems. RESULTS: Readmission rates at 90 days for cemented and uncemented stems were 0.18 and 0.16, respectively (Chi-square 0.12, P = 0.71). The average subsidence (mm) in cemented and uncemented stems was 3.71 and 5.16 (P < 0.0001), respectively. There were 22 and 33 intraoperative fractures in the cemented and uncemented groups, respectively (Chi-square 0.40, P = 0.53). There were four postoperative periprosthetic fractures in the cemented group and ten in the uncemented group (Chi-square 1.21, P = 0.27). CONCLUSION: This study demonstrated that wedge-tapered stems using the French Paradox cement technique resulted in low failure rates and minimal subsidence, similar to what is reported in the literature. This study is the largest and sole investigation of its kind to reinforce the utility of wedge-taper stems with a French Paradox cement technique.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Pisquiy JJ, Booth M, Agard T, et al. Operative Outcomes of Cemented Hip Arthroplasty: An Examination of the French Paradox. J Arthroplasty. 2026. PMID: 42880556. doi:10.1016/j.arth.2026.10.007

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。