双动与单动全髋关节置换术股骨假体周围骨折率比较:780例非骨水泥髋的回顾性倾向匹配研究
单中心回顾性分析1415例非骨水泥全髋关节置换术,比较双动(DM-THA)与陶瓷对陶瓷(CoC-THA)假体。DM-THA组假体周围骨折(PPF)发生率显著高于CoC-THA组(4.0% vs 0.8%,OR 4.8,95%CI 1.86-12.4,p=0.001),倾向匹配后仍显著(OR 3.5,95%CI 1.3-8.6,p=0.007)。DM-THA组脱位率显著低于CoC-THA组(匹配后0.4% vs 4.0%,OR 0.09,95%CI 0.02-0.49,p=0.005)。
要点
- DM-THA组PPF发生率4.0%(17/425),显著高于CoC-THA组0.8%(8/990),OR 4.8。
- 倾向匹配后DM-THA组PPF风险仍显著增高(OR 3.5,95%CI 1.3-8.6,p=0.007)。
- DM-THA组脱位率显著低于CoC-THA组(匹配后0.4% vs 4.0%,OR 0.09,p=0.005)。
核心结论
- DM-THA虽有效降低脱位风险,但相比标准假体可能增加假体周围骨折发生率,尤其在因股骨颈骨折行THA的患者中。
研究设计与样本
- 单中心回顾性研究,分析2017年1月至2024年12月共1415例非骨水泥THA患者(DM-THA 425髋,CoC-THA 990髋),对年龄、性别、BMI和手术指征进行倾向评分匹配,匹配后DM-THA 260例、CoC-THA 520例。
主要发现
- 总体队列中DM-THA组PPF发生率4.0%(17/425),CoC-THA组0.8%(8/990),OR 4.8(95%CI 1.86-12.4),p=0.001。
- 倾向匹配后DM-THA组PPF风险仍显著增高,OR 3.5(95%CI 1.3-8.6),p=0.007。
- 股骨颈骨折作为手术指征在总体和匹配队列中均与PPF风险增加独立相关。
- 倾向匹配后DM-THA组脱位率0.4%(1/260),显著低于CoC-THA组4.0%(21/520),OR 0.09(95%CI 0.02-0.49),p=0.005。
- 股骨颈骨折也与脱位风险增高相关;假体类型与手术指征之间对PPF或脱位均无显著交互作用。
关键数值与推荐
- DM-THA组PPF发生率4.0%(17/425) vs CoC-THA组0.8%(8/990),OR 4.8(95%CI 1.86-12.4),p=0.001。
- 倾向匹配后PPF的OR 3.5(95%CI 1.3-8.6),p=0.007。
- 倾向匹配后脱位率DM-THA组0.4%(1/260) vs CoC-THA组4.0%(21/520),OR 0.09(95%CI 0.02-0.49),p=0.005。
临床怎么用
- 在因股骨颈骨折行THA的患者中,选择双动假体需权衡其降低脱位与增加假体周围骨折的风险。
局限性
- 单中心回顾性设计,可能存在选择偏倚和未测量混杂因素。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
AIMS: Dual-mobility implants have reduced dislocation rates in total hip arthroplasty (THA), particularly in high-risk populations. However, under conditions of high stress, such as a fall or forced range of motion, the energy that would otherwise cause dislocation is instead transmitted distally along the femoral component and into the surrounding bone. Therefore, concerns remain regarding their potential impact on the risk of periprosthetic fracture (PPF). METHODS: In a single-centre study, we retrospectively analyzed 1,415 patients who underwent uncemented THA with either a dual-mobility (DM-THA; 425 hips) or ceramic-on-ceramic (CoC-THA; 990 hips) bearing between January 2017 and December 2024. Propensity score matching (PSM) was performed for age, sex, BMI, and surgical indication, yielding a matched cohort of 260 DM-THA and 520 CoC-THA patients. Incidences of PPF, dislocation, and mortality were compared. RESULTS: PPF occurred significantly more frequently in the DM-THA group than in the CoC-THA group (4.0% (17/425) vs 0.8% (8/990); odds ratio (OR) 4.8 (95% CI 1.86 to 12.4); p = 0.001), a finding confirmed after PSM (OR 3.5 (95% CI 1.3 to 8.6); p = 0.007). Femoral neck fracture (FNF) as the surgical indication was independently associated with an increased risk of PPF in both the overall and matched cohorts. In contrast, DM-THA was associated with a significantly lower dislocation rate compared with CoC-THA after PSM (0.4% (1/260) vs 4.0% (21/520); OR 0.09 (95% CI 0.02 to 0.49); p = 0.005). FNF was also associated with a higher risk of dislocation. No significant interaction was observed between bearing type and surgical indication for either PPF or dislocation. CONCLUSION: While DM-THA effectively reduces dislocation risk, it may be associated with a higher incidence of PPF compared with standard constructs in patients undergoing THA for FNF. These findings underscore the need to carefully weigh the risks and benefits of dual-mobility bearings.
引用
- Komat M, Sabot L, Simion F, et al. Higher femoral periprosthetic fracture rate with dual-mobility compared with single-mobility total hip arthroplasty : a retrospective propensity-matched study of 780 uncemented hips. Bone Joint J. 2026. PMID: 42853085. doi:10.1302/0301-620X.108B10.BJJ-2025-1810.R2
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。