肿瘤旋转成形术的手术并发症:系统综述
该系统综述纳入26项研究共746例下肢骨肉瘤旋转成形术患者,34%出现术后并发症,最常见为骨重建相关(11%),其次为血管(8%)和伤口愈合(7%)。骨相关并发症75%发生于术后第一年,血管并发症94%发生于术后14天内。
要点
- 旋转成形术后34%患者发生并发症,骨重建相关最常见(11%)。
- 血管并发症94%发生于术后14天内,需早期监测。
- 骨相关并发症75%发生于术后第一年,需长期随访。
核心结论
- 旋转成形术是下肢骨肉瘤耐用且功能良好的生物重建选择,但34%患者出现术后并发症。
- 并发症以骨重建相关最常见,其次为血管和软组织并发症;早期并发症风险小但严重,骨愈合后显著降低。
研究设计与样本
- 系统综述,检索PubMed和Scopus数据库(1948年至2024年11月15日),纳入26项研究共746例下肢骨肉瘤旋转成形术患者。
- 纳入标准:肿瘤指征、下肢手术、队列>10例、明确报告术后并发症;采用NOS和GRADE评估方法学质量,未进行正式meta分析。
主要发现
- 746例患者中34%(254例)报告并发症,27例有多种并发症,总并发症数281。
- 最常见并发症为骨重建相关(11%,81/746),其次血管系统(8%,59/746)、伤口愈合(7%,55/746)、神经损伤(5%,35/746)和感染(4%,31/746)。
- 骨重建相关并发症75%(36/48)发生在术后第一年内,血管并发症94%(31/33)发生在术后14天内。
- 骨肉瘤占71%(527/746),股骨远端最常见(56%,419/746);性别报告中男性占65%(321/491),手术年龄3至64岁。
关键数值与推荐
- 血管管理:65%(309/476)采用吻合构造,35%(167/476)采用loop procedure。
- 骨固定:92%(327/354)使用钢板螺钉构造,3%(10/354)使用髓内钉。
临床怎么用
- 术前咨询应告知患者34%并发症风险,重点关注骨重建、血管和伤口愈合相关并发症。
- 术后14天内密切监测血管并发症,第一年内随访骨重建相关并发症。
局限性
- 纳入研究方法学质量中至差(NOS和GRADE评估),总体偏倚风险中至差。
- 许多研究对手术并发症报告不充分,数据仅汇总未进行正式meta分析。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: In the surgical treatment of lower extremity sarcomas, rotationplasty provides a durable biologic reconstruction option. It effectively allows the patient to function with a transtibial amputation, without the burden of a nonbiologically based reconstruction. Despite robust function and durability, rotationplasty may invite its own array of complications. A thorough description of rotationplasty complications and outcomes is lacking in published reports, limiting effective patient and family counseling. Moreover, improving awareness of the potential complications will allow surgeons the opportunity to mitigate their risk of occurrence or detect them early in order to minimize their downstream consequences. QUESTIONS/PURPOSES: (1) What are the modes of complication and the proportion at which they occur after oncologic rotationplasty surgery? (2) What is the timing of these complications relative to the index surgical procedure? (3) What proportion of patients ultimately undergo conversion to an amputation, and when, relative to the index rotationplasty, does conversion occur? METHODS: We performed a review through the PubMed and Scopus databases for rotationplasty procedures for oncologic indications between 1948 and November of 2024 (both last searched November 15, 2024). This yielded 293 articles; 117 were excluded because they did not include the rotationplasty procedure. We then excluded 15 studies for a nononcologic indication for surgery, 101 studies with cohorts of < 10 patients, 14 for inadequate reporting of postoperative complications, and 20 for duplication of published data by the same study group. We included manuscripts if they had an oncologic indication for the procedure, a lower extremity procedure, a cohort of > 10 patients, and clear reporting of postoperative complications. Ultimately, 26 articles were included in this review. Two different authors screened and extracted clinical metrics, which they recorded in a spreadsheet for collation and evaluation. Risk of bias and methodological quality of the included studies was quantitatively assessed via two methods: the Newcastle-Ottawa Scale (NOS) and the Grading of Recommendations Assessment, Development, and Evaluation (GRADE) approach. Overall risk of bias and methodological quality of the included studies was moderate to poor. Data were pooled for ease of comprehension, but we did not perform a formal meta-analysis of the data. In the papers that reported gender, most patients were boys or men (65% [321 of 491]). The age at time of surgery ranged from 3 to 64 years. Osteosarcoma was the most common diagnosis, accounting for 71% (527 of 746) of diagnoses, and the distal femur was the most common location (56% [419 of 746]). Regarding surgical techniques, for those with reported data concerning vascular management, 65% (309 of 476) utilized an anastomosis construct, whereas 35% (167 of 476) underwent a loop procedure. For osteosynthesis, most reported data demonstrated use of a plate and screw construct (92% [327 of 354]) rather than an intramedullary nail (3% [10 of 354]). RESULTS: There were 746 patients in the included 26 articles, 34% (254) of whom were reported to have had a complication. Twenty-seven patients within our cohort were reported to have had multiple complications, so the total number of reported complications was 281. The most common complications involved the osseous construct (11% [81 of 746]), followed by the vascular system (8% [59 of 746]), then wound healing (7% [55 of 746]). Other less commonly reported complications were neurologic injuries (5% [35 of 746]) and infection (4% [31 of 746]). With regard to timing of postoperative complications, 75% (36 of 48) of osseous construct-related issues arose within the first year, and 94% (31 of 33) of vascular complications occurred within 14 days of surgery. Details of surgical complications were not adequately reported in many series within our cohort. CONCLUSION: Our review suggests that 34% of all patients with rotationplasty experienced a postoperative complication, the most common being osseous construct-related, followed by vascular and soft tissue complications. These data suggest that rotationplasty is a robust, durable reconstruction option for patients undergoing surgery for a lower extremity bone sarcoma. It carries small yet serious early complication risks; however, this dramatically tapers after osteosynthesis is achieved. A prospective review of multi-institutional perioperative data would allow for a more comprehensive and comparative summary of these procedures to investigate the surgical factors that influence the occurrence of complications and reoperation. LEVEL OF EVIDENCE: Level IV, therapeutic study.
引用
- Lavin C, Frenette RS, Brown KM, et al. What Are the Surgical Complications Associated With Oncologic Rotationplasty Procedures? A Systematic Review. Clin Orthop Relat Res. 2026. PMID: 42814611. doi:10.1097/CORR.0000000000004098
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。