术前内侧近端胫骨角小于84°不影响无限制运动学对齐全膝关节置换术后两年临床结果:倾向性评分匹配研究
该回顾性倾向性评分匹配队列研究纳入238例无限制运动学对齐全膝关节置换术(KA-TKA)和476例机械对齐全膝关节置换术(MA-TKA),随访至少2年。KA组按术前内侧近端胫骨角(MPTA)分层:≥84°组(156例,平均86.6°)和<84°组(82例,平均81.6°)。结果显示,严重胫骨近端内翻(平均MPTA 81.6°)患者接受无限制KA-TKA后,患者报告结局指标、满意度和生存率与畸形较轻者及MA-TKA组相当。
要点
- 严重胫骨近端内翻(MPTA<84°)患者KA-TKA术后2年PROMs与MPTA≥84°者及MA-TKA相当。
- KA组患者满意度显著高于MA-TKA组(6个月P=0.015,2年P=0.017)。
- 2年无翻修生存率优良,仅2例翻修和4例膝关节手法操作。
核心结论
- 在平均MPTA 81.6°的严重胫骨近端内翻患者中,无限制KA-TKA术后2年患者报告结局指标、满意度和生存率与畸形较轻者及MA-TKA队列相当。
研究设计与样本
- 回顾性倾向性评分匹配队列研究,纳入238例无限制KA-TKA和476例MA-TKA,随访至少2年。
- KA队列按术前MPTA分层:≥84°组(n=156,平均MPTA 86.6°)和<84°组(n=82,平均MPTA 81.6°)。
主要发现
- 术后6个月,MPTA≥84°组膝关节社会评分(KSKS)显著优于MPTA<84°组(P=0.033)和MA-TKA组(P<0.001)。
- 术后2年,MPTA≥84°组KSKS显著优于MA-TKA组(P=0.032),但与MPTA<84°组无显著差异(P=0.555)。
- 其他患者报告结局指标组间无显著差异;KA两组满意度在6个月和2年随访时均显著高于MA-TKA组(P=0.015和P=0.017)。
- Kaplan-Meier曲线显示2年无翻修生存率优良,共2例翻修和4例膝关节手法操作。
临床怎么用
- 对于术前MPTA<84°的严重胫骨近端内翻患者,无限制KA-TKA可考虑作为治疗选择,但需结合个体情况。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Unrestricted kinematic alignment (KA) total knee arthroplasty (TKA) may accept tibial component varus beyond conventional thresholds, yet outcomes in marked proximal tibial varus remain understudied in Southeast Asian populations. Our study evaluated 2-year outcomes after unrestricted KA-TKA in patients who had severe proximal tibial varus using mechanically aligned total knee arthroplasty (MA-TKA) as a control. METHODS: This retrospective, propensity score-matched cohort study included 238 unrestricted KA-TKAs and 476 MA-TKAs with minimum 2-year follow-up. The KA cohort was stratified by preoperative medial proximal tibial angle (MPTA): ≥ 84° (Group 1, n = 156, mean MPTA 86.6°) versus less than 84° (Group 2, n = 82, mean MPTA 81.6°). The following variables were compared: (1) demographic data, (2) patient-reported outcome measures (PROMs) including Short Form-36 domains, Oxford Knee Score, Knee Society Function Score and Knee Society Knee Score (KSKS), patient satisfaction and expectations, and (3) radiological parameters including MPTA, lateral distal femoral angle, arithmetic hip-knee-ankle angle, and joint line obliquity. Kaplan-Meier analyses assessed revision-free survival. RESULTS: At six months, Group 1 demonstrated significantly better KSKS than Group 2 and MA-TKA (P = 0.033 and P < 0.001, respectively). This persisted for two years, with Group 1 achieving significantly better KSKS (P = 0.032) than MA-TKA but not against Group 2 (P = 0.555). There were no between-group differences detected for other PROMs, but significantly more patients were satisfied in Groups 1 and 2 compared with MA-TKA at six month and 2-year follow-up (P = 0.015 and P = 0.017, respectively). Kaplan-Meier curves showed excellent 2-year revision-free survival with two surgical revisions and four knee manipulations. CONCLUSIONS: At 2-year follow-up, in patients who have severe proximal tibial varus (mean MPTA 81.6°), unrestricted KA-TKA achieved comparable PROMs, excellent patient satisfaction, and survivorship relative to patients who had less severe deformity and the MA-TKA cohort.
引用
- Ng Y, Lim WSR, Lam LZL, et al. Preoperative Medial Proximal Tibial Angle of Less Than 84° Does Not Compromise Two-Year Clinical Outcomes After Unrestricted Kinematic Alignment Total Knee Arthroplasty: A Propensity Score-Matched Study. J Arthroplasty. 2026. PMID: 42697451. doi:10.1016/j.arth.2026.08.061
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。