文献速递关节外科创伤骨科

保留关节周围硬件不增加转换全膝关节置换术的再手术风险

Periarticular Hardware Retention Does Not Increase Reoperation Risk in Conversion Total Knee Arthroplasty.
PubMed 文献 · J Arthroplasty · 2026-09-02

本研究回顾性纳入2009至2019年间320例接受转换或初次全膝关节置换术的患者,按术中复杂度分为无保留硬件组(171例)、保留「 minor」硬件组(90例)和保留「major」硬件组(59例)。主要结局显示三组再手术风险无显著差异(Fine-Gray分析P=0.162),但major硬件组手术时间和失血量显著更高(P<0.001),且术后1年VR-12精神评分和UCLA活动评分改善较低(P=0.034和P=0.016)。结论认为保留关节周围硬件不增加再手术率或2年患者报告结局,但增加手术时间、失血和早期并发症。

要点

  • 保留关节周围硬件不增加转换全膝关节置换术的再手术风险(P=0.162)。
  • major硬件组手术时间和失血量显著更高(P<0.001)。
  • major硬件组术后1年VR-12精神评分和UCLA评分改善较低。

核心结论

  • 保留关节周围硬件与转换全膝关节置换术的手术时间、失血和早期并发症增加相关,尤其是钢板或髓内钉。
  • 保留硬件不增加再手术率或2年患者报告结局。

研究设计与样本

  • 回顾性队列研究,纳入2009至2019年间320例接受转换或初次全膝关节置换术的患者。
  • 患者按术中复杂度分为无保留硬件组(n=171)、保留「minor」硬件组(n=90)和保留「major」硬件组(n=59)。
  • 主要结局再手术风险采用风险调整的Fine-Gray亚分布风险模型,以死亡为竞争事件。

主要发现

  • 三组再手术风险无显著差异(多变量Fine-Gray分析P=0.162)。
  • major硬件组手术时间和失血量显著更高(P<0.001)。
  • 住院时间和并发症率在各组间有差异(P<0.05)。
  • 术后1年major硬件组VR-12精神评分和UCLA评分改善较低(P=0.034和P=0.016)。

临床怎么用

  • 转换全膝关节置换术时保留关节周围硬件需权衡手术时间、失血和早期并发症风险。
  • 保留major硬件(如钢板或髓内钉)可能需关注术后1年患者报告结局的改善程度。

局限性

  • 证据等级为III级,回顾性比较研究。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Total knee arthroplasty (TKA) in the setting of retained periarticular hardware presents technical challenges and may influence surgical complexity and outcomes. This study aimed to evaluate whether hardware retention at the time of conversion TKA impacts the reoperation risk, perioperative outcomes, and patient-reported outcome measures. METHODS: A retrospective cohort study was conducted of 320 patients who underwent conversion or primary TKA between 2009 and 2019. Patients were categorized into three groups: no retained hardware (n = 171), retained "minor" hardware (n = 90), and retained "major" hardware (n = 59) based on intraoperative complexity. The primary outcome was the risk of reoperation and was assessed using a risk-adjusted Fine-Gray subdistribution hazard model that adjusted for death as a competing event. The secondary outcomes included operative time, blood loss, length of stay, complications, and patient-reported outcome measures (University of California, Los Angeles Activity Score, Veterans RAND 12-Item (VR-12) Health Survey Physical and Mental Component Scores) were assessed using univariate tests. RESULTS: There were no significant differences in the risk of reoperation among the three groups (multivariable Fine-Gray analysis: P = 0.162). Operative time and blood loss were significantly higher in the major hardware group (P < 0.001). Length of stay and complication rates also varied across groups (P < 0.05). The patient-reported outcome measures at one and two years showed minor differences, with lower improvements in VR-12 Mental Scores and University of California, Los Angeles scores in the major hardware group at one year (P = 0.034 and P = 0.016, respectively). CONCLUSIONS: While periarticular hardware retention in conversion TKA was associated with increased operative time, blood loss, and early complications, especially with plates or intramedullary nails, it was not associated with higher reoperation rates or 2-year patient-reported outcomes. LEVEL OF EVIDENCE: Level III, retrospective comparative study.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Tantikosol P, Apinyankul R, Wong HJ, et al. Periarticular Hardware Retention Does Not Increase Reoperation Risk in Conversion Total Knee Arthroplasty. J Arthroplasty. 2026. PMID: 42685935. doi:10.1016/j.arth.2026.08.052

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。