定制单髁膝关节置换术后的患者报告结局
单机构回顾性研究比较定制与现成单髁膝关节置换术,共纳入623例患者(定制124例,现成499例),随访至少2年。两组患者报告结局指标(PROMs)绝对评分、变化值及最小临床重要差异达成率均无显著差异(均P > 0.05)。定制组2年翻修率更高(8.9% vs 3.8%,P = 0.010),无菌性松动更常见(4.8% vs 0.8%,P = 0.006)。
要点
- 定制与现成单髁膝关节置换术在PROMs各指标上均无显著差异。
- 定制组2年翻修率显著高于现成组(8.9% vs 3.8%)。
- 定制组无菌性松动翻修率显著更高(4.8% vs 0.8%)。
核心结论
- 定制单髁膝关节置换术在患者报告结局上未优于现成假体,且2年翻修率更高。
研究设计与样本
- 单机构回顾性数据库查询,纳入内侧单髁膝关节置换术患者,随访至少2年且完成术前术后PROMs,共623例(定制124例,现成499例)。
主要发现
- 两组PROMIS Global Physical、PROMIS Global Mental、PROMIS Physical Function Short Form 10-a及KOOS Physical Function Short Forms的绝对评分、变化值及最小临床重要差异达成率均无显著差异(均P > 0.05)。
- 定制组2年翻修率8.9%,现成组3.8%(P = 0.010)。
- 定制组无菌性松动翻修率4.8%,现成组0.8%(P = 0.006)。
- 其他翻修指征及所有其他评估并发症两组无显著差异(均P > 0.05)。
关键数值与推荐
- 定制组2年翻修率8.9% vs 现成组3.8%(P = 0.010)。
- 定制组无菌性松动翻修率4.8% vs 现成组0.8%(P = 0.006)。
临床怎么用
- 选择单髁膝关节置换假体时,定制假体的理论优势未转化为更好的PROMs,且需关注更高的早期翻修及无菌性松动风险。
局限性
- 单机构回顾性研究设计可能引入选择偏倚。
- 随访时间仅2年,无法评估长期结局。
- 定制组样本量较小(124例),可能影响部分比较的统计效能。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Custom unicompartmental knee arthroplasty (UKA) implants were developed to improve component fit and alignment compared to conventional off-the-shelf (OTS) implants. However, evidence supporting the clinical advantage of custom UKA remains limited. This study compared patient-reported outcome measures (PROMs) and complication rates following custom and OTS UKA. METHODS: A single-institution database was queried for patients who underwent medial UKA. Patients who had at least two years of follow-up and completed preoperative and postoperative PROMs were included. A total of 623 patients met inclusion criteria, including 124 who received custom implants and 499 who received OTS implants. The Patient-Reported Outcomes Measurement Information System (PROMIS) Global Physical, PROMIS Global Mental, PROMIS Physical Function Short Form 10-a, and Knee Injury and Osteoarthritis Outcome Score Physical Function Short Forms were extracted. The change in (delta) scores and proportions of minimal clinically important difference achievement were evaluated. The 90-day complications and two-year revision rates were also assessed. There were no differences in baseline demographics or comorbidities between cohorts. RESULTS: Patients who received custom and OTS UKA demonstrated comparable absolute PROM scores, delta scores, and rates of achieving minimal clinically important difference across all metrics (all P > 0.05). At 2-year follow-up, patients who received custom UKA had a higher rate of revision surgery compared to those who received OTS implants (8.9 versus 3.8%, P = 0.010). Aseptic loosening was more likely following custom UKA (4.8 versus 0.8%, P = 0.006). Other indications for revision, and all other assessed complications, were comparable between cohorts (all P > 0.05). CONCLUSIONS: Custom UKA implants were associated with a higher revision rate at 2-year follow-up and demonstrated no advantage over OTS implants in terms of PROMs. These findings suggest that the theoretical advantages of custom UKA may not translate to improved clinically meaningful outcomes compared to OTS UKA.
引用
- Mannina CM, Ilyas MH, Kang H, et al. Patient-Reported Outcomes Following Custom Unicompartmental Knee Arthroplasty. J Arthroplasty. 2026. PMID: 42735864. doi:10.1016/j.arth.2026.09.008
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。