传统截骨导向与机械臂辅助内侧单髁膝关节置换的前瞻性双盲随机对照试验
这项前瞻性双盲随机对照试验将107例症状性内侧间室膝骨关节炎患者随机分为传统截骨导向单髁置换组(CO UKA,n=52)和机械臂辅助单髁置换组(RO UKA,n=55),两组均采用CT规划。中期结果显示RO UKA在股骨和胫骨组件位置执行准确性上更优,住院疼痛评分更低、阿片类药物用量更少、住院时间更短,但两组在两年随访时的Oxford膝关节评分、KOOS和WOMAC无差异;RO UKA在6个月和两年随访时的遗忘关节评分更优。
要点
- RO UKA在实现计划股骨和胫骨组件位置方面准确性优于CO UKA。
- RO UKA与更低的住院疼痛评分、更少的阿片类药物用量和更短的住院时间相关。
- 两组两年随访的Oxford膝关节评分、KOOS和WOMAC无差异,RO UKA的遗忘关节评分更优。
核心结论
- RO UKA在实现计划股骨和胫骨组件位置方面准确性更高,早期功能恢复更好,住院时间更短。
- RO UKA在短期至中期随访中遗忘关节评分高于CO UKA。
研究设计与样本
- 前瞻性双盲随机对照试验,纳入107例症状性内侧间室膝骨关节炎患者,随机分为CO UKA组(n=52)和RO UKA组(n=55)。
- 两组均采用CT规划,均使用内侧髌旁入路,并接受标准化术后康复方案,术后两年内定期记录预设结局。
主要发现
- RO UKA在实现计划股骨组件位置(p < 0.001)和胫骨组件位置(p < 0.001)方面准确性优于CO UKA。
- RO UKA与住院疼痛评分降低(p < 0.001)、住院阿片类药物用量减少(p = 0.008)和住院时间缩短(p = 0.004)相关。
- 两年随访时两组Oxford膝关节评分(p = 0.299)、KOOS(p = 0.261)和WOMAC(p = 0.281)无差异。
- RO UKA在6个月(p = 0.002)和两年(p = 0.021)随访时遗忘关节评分更优。
临床怎么用
- 对于内侧间室膝骨关节炎患者,RO UKA可提高组件位置准确性并改善早期恢复,但需考虑患者偏好增加对随机对照试验招募的影响。
局限性
- 试验期间患者招募下降,因越来越多符合条件患者偏好RO UKA,且手术医生临床均势降低。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
AIMS: This study reports the interim outcomes of a randomized controlled trial comparing the accuracy of component positions, early functional outcomes, patient-reported outcome measures, and complications in conventional jig-based unicompartmental knee arthroplasty with navigational control (CO UKA) with robotic arm-assisted unicompartmental knee arthroplasty (RO UKA) for patients who have medial compartment knee osteoarthritis (OA). METHODS: In total, 107 patients with symptomatic medial compartment OA were prospectively randomized to undergo CO UKA (n = 52) or RO UKA (n = 55), representing the currently available recruited cohort. Patients in both treatment groups had CT-based surgical planning. All procedures were completed using the medial parapatellar approach, and all patients received a standardized postoperative rehabilitation programme. Predefined study outcomes were recorded at regular intervals for two years after surgery. RESULTS: RO UKA was associated with increased accuracy in executing the planned femoral (p < 0.001) and tibial (p < 0.001) component positions compared with CO UKA. RO UKA was associated with reduced inpatient pain scores (p < 0.001), decreased inpatient opioid analgesia consumption (p = 0.008), and shorter length of hospital stay (p = 0.004) compared with CO UKA. There were no differences between the treatment groups in the Oxford Knee Score (p = 0.299), Knee Injury and Osteoarthritis Outcome Score (p = 0.261), and Western Ontario and McMaster Universities Arthritis Index (p = 0.281) at two-year follow-up. RO UKA was associated with improved Forgotten Joint Score (FJS) at six-month (p = 0.002) and two-year (p = 0.021) follow-up. Patient recruitment declined during the trial as an increasing proportion of eligible patients expressed a preference for RO UKA, and operating surgeons experienced reduced clinical equipoise between the treatment groups. CONCLUSION: The interim results of this study show that RO UKA was associated with increased accuracy in achieving the planned femoral and tibial component positions, improved early functional recovery, and decreased length of hospital stay compared with CO UKA. RO UKA was associated with higher FJSs compared with CO UKA at short- to mid-term follow-up.
引用
- Kayani B, Fontalis A, Tahmassebi J, et al. A prospective double-blinded randomized controlled trial comparing conventional jig-based versus robotic arm-assisted medial unicompartmental knee arthroplasty. Bone Joint J. 2026. PMID: 42674575. doi:10.1302/0301-620X.108B9.BJJ-2025-1481.R1
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。