文献速递关节外科

后稳定型与交叉韧带保留型全膝关节置换术未置换髌骨术后髌骨摩擦音发生率

Incidence of Postoperative Patellar Crepitus in Total Knee Arthroplasty With Unresurfaced Patellae in Cruciate-Retaining and Posterior-Stabilized Designs.
PubMed 文献 · J Arthroplasty · 2026-08-06

该回顾性研究纳入845例首次全膝关节置换术且髌骨未置换的患者,比较后稳定型(PS)与交叉韧带保留型(CR)假体术后1年髌骨摩擦音的发生率。结果显示总体发生率为9.8%,PS组(12.3%)显著高于CR组(5.7%)(P=0.0002),多数摩擦音无症状,仅6例因摩擦音接受再手术。

要点

  • PS假体术后髌骨摩擦音发生率显著高于CR假体(12.3% vs 5.7%,P=0.0002)。
  • 总体摩擦音发生率为9.8%,其中仅14例有疼痛,6例需再手术。
  • 术前存在摩擦音及术中需外侧支持带松解与术后摩擦音发生相关。

核心结论

  • 在现代全膝关节置换术设计中,髌骨未置换时PS假体术后摩擦音发生率高于CR假体。
  • 多数术后髌骨摩擦音患者无症状,仅少数需再手术。

研究设计与样本

  • 回顾性 review,纳入845例首次全膝关节置换术且髌骨未置换的患者,术后至少随访1年。
  • 记录摩擦音发生率(症状性与无症状性)、患者人口学资料、假体设计、松解情况、功能及患者报告结局,并统计再手术和不良事件。

主要发现

  • 总体术后摩擦音发生率为9.8%(83/845)。
  • PS组摩擦音发生率为12.3%(65/527),CR组为5.7%(18/318),组间差异有统计学意义(P=0.0002)。
  • 83例发生摩擦音的患者中,14例为疼痛性摩擦音,最终6例因摩擦音接受再手术。
  • 股骨假体设计类型与术后摩擦音发生率显著相关(P=0.0003),CR设计摩擦音发生率最低。
  • 术前存在摩擦音的患者更可能需要松解(P=0.0207);术后发生摩擦音的患者术中需要松解的比例也显著更高(P<0.0001)。

临床怎么用

  • 对于髌骨未置换的患者,选择PS假体时应告知其术后髌骨摩擦音风险高于CR假体。
  • 多数术后摩擦音无症状,可向患者说明此点以避免不必要的焦虑。

局限性

  • 本研究为回顾性 review,可能存在选择偏倚和记录不全。
  • 随访时间至少1年,未报告更长期结果。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Patellar crepitus is a complication most seen in patients implanted with a posterior-stabilized (PS) total knee arthroplasty (TKA). The primary objective of the study was to examine the incidence of patellar crepitus in unresurfaced patellae in modern PS- and cruciate-retaining (CR)-TKA designs. METHODS: A retrospective review of 845 patients who underwent TKA whose patellae were left unresurfaced and had a 1-year minimum postoperative follow-up was included in the study. Patellar crepitus incidence (symptomatic versus asymptomatic), patient demographics, implant design, release performed, function, and patient-reported outcomes were recorded. Reoperations and adverse events were documented. Statistical analyses were performed to determine differences in incidence of crepitus and both clinical and functional outcomes. RESULTS: The overall incidence of postoperative crepitus was 9.8% (83 of 845). The PS knees were more likely to develop crepitus than CR knees (12.3% [65 of 527] versus 5.7% [18 of 318]; P = 0.0002). Of the 83 patients who developed crepitus, 14 patients had painful crepitus, and ultimately, six patients underwent reoperation due to crepitus. The type of femoral implant design was significantly associated with the incidence of crepitus postoperatively (P = 0.0003). The CR TKA design was associated with the lowest incidence of developing postoperative crepitus. Patients who had preoperative crepitus were more likely to require a release (P = 0.0207) and those who developed crepitus postoperatively were also significantly more likely to require release during surgery compared to those who did not develop crepitus (P < 0.0001). CONCLUSIONS: In the setting of modern TKA designs, PS-TKA implants demonstrated a higher incidence of postoperative crepitus than CR-TKA implants in those with unresurfaced patellae. Most patients who had crepitus remain asymptomatic. These data may assist providers in appropriate education for patients regarding crepitus in unsurfaced patellae.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Barton KI, Aprey NC, Hemmerle MR, et al. Incidence of Postoperative Patellar Crepitus in Total Knee Arthroplasty With Unresurfaced Patellae in Cruciate-Retaining and Posterior-Stabilized Designs. J Arthroplasty. 2026. PMID: 42562206. doi:10.1016/j.arth.2026.07.060

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。