文献速递关节外科

股胫尺寸不匹配不增加固定平台全膝关节置换的聚乙烯磨损:取回分析

Femoro-Tibial Size Mismatch Does Not Increase Polyethylene Wear in Fixed-Bearing Total Knee Arthroplasty: A Retrieval Analysis.
PubMed 文献 · J Arthroplasty · 2026-07-30

本研究对2008至2024年间翻修的105例固定平台全膝关节置换假体进行取回分析,按股骨与胫骨尺寸匹配情况分组,用改良Hood评分评估聚乙烯磨损。结果显示尺寸不匹配与总体或承重面磨损无关,仅股骨大于胫骨组背侧磨损轻度增加,但未影响假体生存率。

要点

  • 股胫尺寸不匹配未增加总体聚乙烯磨损或承重面磨损。
  • 股骨大于胫骨组背侧磨损略高,但未导致假体生存率下降。
  • 在体时间和高龄是磨损的独立预测因素。

核心结论

  • 股胫尺寸不匹配不导致总体或承重面聚乙烯磨损增加,背侧磨损轻度增加未转化为生存率降低。

研究设计与样本

  • 回顾性取回分析,纳入2008至2024年间翻修的固定平台全膝关节置换假体共105例。

主要发现

  • 总体聚乙烯磨损评分三组间无差异(匹配组47.6±23.6,股骨大于胫骨组46.1±22.6,股骨小于胫骨组51.3±19.4,P=0.81,Cohen's d<0.20)。
  • 多水平模型显示不匹配与总体磨损无关(Wald卡方=0.42,P=0.81)。
  • 存在表面与不匹配的显著交互作用(P<0.001):股骨大于胫骨组背侧磨损高于匹配组(P=0.021,d约0.37),但承重面磨损未增加(P=0.24)。
  • 在体时间(P<0.001)和高龄(P=0.014)是磨损的独立预测因素。
  • 不匹配不影响假体生存率,在体时间无差异(Cox P=0.456)。

关键数值与推荐

  • 采用改良Hood评分系统对聚乙烯内衬进行磨损分级。
  • 磨损机制以抛光、划痕和点蚀为主。

临床怎么用

  • 固定平台全膝关节置换中股胫尺寸不匹配不应单纯基于聚乙烯磨损风险而避免。
  • 不匹配膝关节翻修风险增高可能涉及聚乙烯磨损以外的机制。

局限性

  • 本研究为取回分析,仅纳入翻修假体,可能存在选择偏倚。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: This study aimed to determine whether femoro-tibial component size mismatch in a fixed-bearing total knee arthroplasty (TKA) design is associated with increased polyethylene (PE) wear. We hypothesized that mismatched knees, particularly those with a femur greater than the tibia, would demonstrate higher PE wear. METHODS: A retrospective retrieval analysis was performed on a fixed-bearing design revised between 2008 and 2024. Implants were categorized as matched (femur = tibia), femur (F) greater than tibia (T), or femur less than tibia. A total of 105 implants were included. The PE inserts were graded using the modified Hood scoring system. Mixed-effects models evaluated associations between mismatch and wear severity across regions and surfaces, and Cox regression analyzed time in situ. RESULTS: Total PE wear did not differ between groups (mean matched 47.6 ± 23.6; F greater than T, 46.1 ± 22.6; F less than, T 51.3 ± 19.4; P = 0.81; Cohen's d < 0.20). In multilevel modeling, mismatch was not associated with overall wear (Wald Chi-square 0.42; P = 0.81). A significant surface × mismatch interaction was identified (P < 0.001): F greater than T knees exhibited greater backside wear compared with matched (P = 0.021; d approximately 0.37), but there was no increase in bearing-surface wear (P = 0.24). Time in situ (P < 0.001) and older age (P = 0.014) were the only independent predictors of wear. Burnishing, scratching, and pitting were the dominant wear mechanisms. Mismatch did not affect implant survival, with no difference in time in situ (Cox P = 0.456). CONCLUSIONS: Femoro-tibial size mismatch did not result in greater total or bearing-surface PE wear. The modest increase in backside wear observed in F greater than T did not translate into reduced survivorship. These findings suggest that the higher revision risk reported in mismatched TKAs may involve mechanisms beyond PE wear alone.