HIV阳性与阴性患者机器人辅助全膝关节置换术功能恢复与影像学结果相当
前瞻性观察性队列分析214例连续机器人辅助全膝关节置换术(RA-TKA),203例完成≥3年随访(HIV阴性162例,HIV阳性41例)。两组围手术期安全性、影像学对线精度及功能结局相似,HIV阳性组满意度更高(97.6% vs 91.4%,P=0.021),无假体周围感染、伤口并发症、机械失败或翻修。
要点
- HIV阳性与阴性患者RA-TKA术后3年功能恢复和影像学对线精度相当。
- HIV阳性组总体满意度更高(97.6% vs 91.4%,P=0.021)。
- 病毒抑制和营养状态比HIV状态本身更影响围手术期风险评估。
核心结论
- 在病毒控制良好的HIV阳性患者中,机器人辅助全膝关节置换术安全有效,3年结局和并发症率与HIV阴性者相当。
研究设计与样本
- 前瞻性观察性队列研究,纳入2019至2021年214例连续机器人辅助全膝关节置换术,203例(HIV阴性162例,HIV阳性41例)完成至少3年随访。
主要发现
- 两组手术时间、失血量、对线精度、软组织松解和康复里程碑相似(所有P > 0.05)。
- 两组功能结局改善相当,包括膝关节协会评分变化(51.9 ± 15.3)和视觉模拟评分变化(-7.0 ± 1.6)。
- 总体满意度高(92.6%),HIV阳性组满意度更高(97.6% vs 91.4%;P = 0.021)。
- 无假体周围感染、伤口并发症、机械失败或翻修发生。
临床怎么用
- 对病毒控制良好的HIV阳性患者,机器人辅助全膝关节置换术可作为安全有效的治疗选择。
- 围手术期风险评估应关注病毒抑制和营养状态,而非仅依据HIV状态。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Robot-assisted total knee arthroplasty (RA-TKA) improves alignment accuracy and soft-tissue preservation, which may be beneficial in biologically vulnerable populations such as people living with human immunodeficiency virus (HIV). However, comparative outcome data in high-prevalence settings remain limited. This study compared perioperative safety, radiographic accuracy, and functional outcomes of RA-TKA in HIV-positive and HIV-negative patients. METHODS: A prospective observational cohort of 214 consecutive RA-TKAs (2019 to 2021) was analyzed; 203 patients (162 HIV-negative, 41 HIV-positive) completed ≥ 3 years of follow-up. All procedures utilized an imageless robotic platform with a standardized surgical and enhanced recovery protocol. Functional outcomes such as Knee Society Score (KSS), visual analog scale (VAS), timed up and go (TUG) test, range of motion, radiographic alignment, complications, and patient satisfaction were compared between groups. RESULTS: Operative time, blood loss, alignment accuracy, soft-tissue releases, and rehabilitation milestones were similar between groups (all P > 0.05). Both cohorts demonstrated meaningful and comparable improvements in functional outcomes, including change in Knee Society Score (51.9 ± 15.3) and change in visual analog scale (-7.0 ± 1.6). Overall satisfaction was high (92.6%), with higher satisfaction among HIV-positive patients (97.6 versus 91.4%; P = 0.021). There were no periprosthetic joint infections, wound complications, mechanical failures, or revisions that occurred. CONCLUSIONS: An RA-TKA is safe and effective in well-controlled HIV-positive patients, achieving 3-year outcomes and complication rates comparable to those of HIV-negative individuals. Viral suppression and nutritional status appear more relevant than HIV status alone in perioperative risk assessment.
引用
- Senyolo I, Goga N, Elebo N, et al. Equivalent Functional Recovery and Radiographic Outcomes in Human Immunodeficiency Virus-Positive and Virus-Negative Patients Undergoing Robot-Assisted Total Knee Arthroplasty. J Arthroplasty. 2026. PMID: 42456786. doi:10.1016/j.arth.2026.07.004
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。