文献速递关节外科

直接前入路全髋关节置换中可吸收深层皮钉降低伤口并发症

Reduced Wound Complications With Absorbable Deep Dermal Staples in Direct Anterior Total Hip Arthroplasty.
PubMed 文献 · J Arthroplasty · 2026-07-22

单术者703例连续初次直接前入路全髋关节置换的回顾性研究,比较可吸收皮内钉(357例)与倒刺缝线(346例)闭合切口。皮钉组伤口并发症率显著低于缝线组(2.8%比8.1%,P<0.002),两组因伤口问题重返手术室无显著差异;发生伤口并发症者BMI更高。

要点

  • 可吸收皮内钉组伤口并发症率2.8%,低于倒刺缝线组的8.1%(P<0.002)。
  • 两组因伤口并发症重返手术室的比例无显著差异。
  • 无论何种闭合方式,发生伤口并发症的患者BMI均更高。

核心结论

  • 可吸收皮钉增强闭合与单纯倒刺缝线相比,伤口并发症显著更少,但肥胖患者风险仍较高。

研究设计与样本

  • 单术者703例连续初次直接前入路全髋关节置换的回顾性研究,分可吸收皮内钉组357例与倒刺缝线组346例。
  • 比较人口学资料、伤口并发症及因伤口问题重返手术室情况,连续变量用非配对t检验,分类变量用卡方或Fisher精确检验。

主要发现

  • 皮钉组伤口并发症率2.8%,显著低于缝线组的8.1%(P<0.002)。
  • 两组因伤口并发症重返手术室的比例无显著差异。
  • 发生伤口并发症者BMI更高:对照组38.2比31.8(P<0.001),皮钉组40.4比31.0(P<0.001)。
  • 发生并发症者倾向更年轻,性别无差异。
  • 基线人口学相似,但皮钉组年龄更大(P<0.001)、BMI更高(P<0.002)。

临床怎么用

  • 对直接前入路全髋关节置换,可考虑用可吸收皮内钉增强闭合以降低伤口并发症,但肥胖患者仍需警惕。

局限性

  • 为单术者回顾性研究,两组年龄与BMI基线存在显著差异。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The direct anterior approach (DAA) for total hip arthroplasty has been increasingly adopted for its muscle-sparing nature. However, wound complications remain a well-documented limitation in DAA cohorts. We evaluated the efficacy of absorbable staple augmentation as an alternative to conventional barbed sutures for incision closure in DAA total hip arthroplasty. We hypothesized that absorbable staple augmentation would be associated with reduced incidence of wound complications, particularly in patients who have elevated body mass index (BMI). METHODS: A retrospective review was performed on 703 consecutive primary DAA cases conducted by a single surgeon. Patients were divided into two groups: absorbable intradermal staples (n = 357) and barbed sutures (n = 346). Demographics, wound complications, and return to the operating room for wound issues were recorded. Statistical analyses included unpaired t-tests for continuous variables and Chi-square or Fisher's exact tests for categorical variables. Baseline demographics were similar, though the stapler group was significantly older (P < 0.001) and had a higher BMI (P < 0.002). RESULTS: The stapler group demonstrated a significantly lower wound complication rate (2.8 versus 8.1%, P < 0.002). Rates of return to the operating room for wound complications were not significantly different between groups. Across both groups, patients who had wound complications had higher BMIs (control: 38.2 versus 31.8, P < 0.001; stapler: 40.4 versus 31.0, P < 0.001). Patients who had complications tended to be younger, with no difference in sex. CONCLUSIONS: Absorbable staple augmentation was associated with significantly fewer complications compared to barbed sutures alone, though obese patients remained at higher risk. Potential mechanisms for improved outcomes may include its longer time to dissolve, precise edge apposition, and clearance of the epidermis, contributing to uniform tension distribution and robust wound healing. Absorbable staple augmentation may provide a practical closure method for prospective studies.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Abuoqab LO, Rice SW, Crawford DA, et al. Reduced Wound Complications With Absorbable Deep Dermal Staples in Direct Anterior Total Hip Arthroplasty. J Arthroplasty. 2026. PMID: 42486200. doi:10.1016/j.arth.2026.07.027

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。