关节置换术中外科烟雾:早期即达不健康水平且风险因术式入路而异
这项单中心前瞻性研究纳入83例初次关节置换(20例直接外侧入路双极半髋、35例直接前入路全髋、28例全膝),用便携监测仪测术中PM2.5并映射空气质量指数(AQI)分级。结果显示双极半髋与全膝的PM2.5中位最高浓度显著高于直接前入路全髋,多数病例在归一化手术时间25%时已达AQI不健康或更差,调整后OR分别为34.280与21.971。
要点
- 双极半髋与全膝术中PM2.5明显高于直接前入路全髋
- 双极半髋80%、全膝71%的病例在25%手术时间点AQI达不健康或更差
- 术式与入路难以轻易改变,需重视排烟与高效口罩等综合控制
核心结论
- 双极半髋(直接外侧入路)与全膝置换术中PM2.5浓度显著高于直接前入路全髋,许多病例达到AQI不健康或更差水平。
- 术式与入路不是易于改变的外科烟雾暴露决定因素,提示需采取排烟与高效口罩等综合控制策略。
研究设计与样本
- 单中心前瞻性研究,共83例初次关节置换:20例双极半髋(直接外侧入路)、35例全髋(直接前入路)、28例全膝。
- 术中用便携监测仪测PM2.5浓度并映射至AQI分级,按术式计算最大值与累积暴露等汇总指标,用逻辑回归估计超过AQI阈值的OR。
主要发现
- 双极半髋与全膝的PM2.5在术野开发阶段急剧升高,而全髋全程保持较低水平。
- 中位最高PM2.5浓度:双极半髋129.50 µg/m³(IQR 85.44至275.28),全髋6.14 µg/m³(IQR 2.54至23.94),全膝118.80 µg/m³(IQR 56.23至208.04)。
- 双极半髋与全膝浓度均显著高于全髋(两者调整后p < 0.001)。
- 归一化手术时间25%时,双极半髋80%、全膝71%的病例AQI达不健康或更差,而多数全髋病例仍在Good或Moderate类别。
- 与全髋相比,达到AQI不健康或更差的调整OR:双极半髋34.280(95%CI 7.479至215.044;p < 0.001),全膝21.971(95%CI 6.011至101.814;p < 0.001)。
关键数值与推荐
- AQI不健康或更差达标率:双极半髋80%、全膝71%(归一化手术时间25%时点)。
- 调整OR(对照全髋):双极半髋34.280(95%CI 7.479至215.044;p < 0.001),全膝21.971(95%CI 6.011至101.814;p < 0.001)。
临床怎么用
- 手术室团队在关节置换术中可能暴露于潜在有害水平的外科烟雾,应了解不同术式与入路的暴露特征。
- 可据此指导优化手术室环境的策略,如排烟与高效口罩等综合控制措施。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Surgical smoke is a gaseous intraoperative byproduct that contains numerous toxic compounds, including fine particles with a diameter of ≤2.5 µm (PM2.5). However, intraoperative exposure during joint arthroplasty has not been well characterized. In this study, we aimed to quantify PM2.5 exposure during arthroplasty and to determine, by procedure and approach, how often it reached potentially harmful levels. METHODS: We conducted a single-center prospective study of 83 primary arthroplasties (20 bipolar hemiarthroplasties [BHAs] via a direct lateral approach, 35 total hip arthroplasties [THAs] via a direct anterior approach, and 28 total knee arthroplasties [TKAs]). Intraoperative PM2.5 concentrations were measured using a portable monitor and were mapped to Air Quality Index (AQI) categories. Summary metrics, including maximum and cumulative PM2.5 exposure, were calculated by procedure. Logistic regression was used to estimate odds ratios (ORs) for exceeding AQI thresholds. RESULTS: In BHA and TKA, PM2.5 concentrations increased sharply during field development, whereas they remained low throughout THA. The median maximum PM2.5 concentrations were 129.50 µg/m 3 (interquartile range [IQR], 85.44 to 275.28 µg/m 3 ) for BHA, 6.14 µg/m 3 (IQR, 2.54 to 23.94 µg/m 3 ) for THA, and 118.80 µg/m 3 (IQR, 56.23 to 208.04 µg/m 3 ) for TKA. The concentrations were significantly higher in BHA and TKA (both adjusted p < 0.001) than in THA. At 25% of the normalized surgical time, 80% of BHA cases and 71% of TKA cases reached an AQI of Unhealthy or worse, whereas most THA cases remained within the Good or Moderate categories. The adjusted ORs for reaching an AQI of Unhealthy or worse were 34.280 (95% confidence interval [CI], 7.479 to 215.044; p < 0.001) for BHA and 21.971 (95% CI, 6.011 to 101.814; p < 0.001) for TKA compared with THA. CONCLUSIONS: BHA via a direct lateral approach and TKA generated substantially higher intraoperative PM2.5 concentrations than THA via a direct anterior approach, and many cases reached an AQI of Unhealthy or worse. Procedure and approach are not readily modifiable determinants of surgical smoke exposure, underscoring the need for comprehensive control strategies, including smoke evacuation and high-efficiency masks, in arthroplasty practice. CLINICAL RELEVANCE: Operating room teams may be exposed to potentially harmful levels of surgical smoke during arthroplasty. Understanding the characteristics of this exposure may help to guide strategies to optimize the operating room environment.
引用
- Tsuchiya R, Suzuki R, Yano S, et al. Intraoperative Surgical Smoke During Arthroplasty: Early Unhealthy-Level Exposure and Approach-Dependent Risk. J Bone Joint Surg Am. 2026. PMID: 42406854. doi:10.2106/JBJS.25.01585
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。