领-股骨距接触可降低Dorr C型股骨早期假体周围骨折与下沉风险
本回顾性研究纳入387例Dorr C型股骨、使用带领全羟基磷灰石涂层非骨水泥柄并经直接前入路行全髋关节置换的髋关节,术后90天内评估领-股骨距间隙。领-股骨距间隙组假体周围骨折与下沉发生率均高于接触组,差异有统计学意义。
要点
- Dorr C型股骨使用带领全HA涂层非骨水泥柄时,完全领-股骨距接触者占95.9%。
- 假体周围骨折仅见于领-股骨距间隙组(18.8%),接触组未见。
- 间隙组下沉发生率为12.5%,高于接触组的0.5%。
核心结论
- 领-股骨距间隙与Dorr C型股骨全髋关节置换术后早期假体周围骨折和下沉风险升高相关。
- 早期假体周围骨折和下沉仅出现在领-股骨距间隙组,支持领部即刻载荷传递的机械重要性。
- 研究支持术中评估领-股骨距接触,尤其在Dorr C型骨中,并支持在能确保接触时使用带领全HA涂层非骨水泥柄。
研究设计与样本
- 回顾性分析2020年9月至2025年6月间实施的6,107例全髋关节置换术。
- 纳入387例Dorr C型股骨、使用带领全HA涂层非骨水泥柄的髋关节,所有手术均采用直接前入路。
- 术后90天内影像学评估领-股骨距间隙,结局为假体周围股骨骨折和/或下沉。
主要发现
- 371髋(95.9%)达到完全领-股骨距接触,16髋(4.1%)存在间隙。
- 3例假体周围骨折均发生于领-股骨距间隙组(18.8%),接触组未见。
- 接触组2髋(0.5%)下沉,间隙组2髋(12.5%)下沉。
- 间隙组下沉和假体周围骨折发生率高于接触组(P = 0.0000282;P = 0.0000584)。
- 事件绝对数较小,但效应量具有临床意义。
关键数值与推荐
- 完全领-股骨距接触371髋(95.9%),存在间隙16髋(4.1%)。
- 间隙组假体周围骨折3例(18.8%),接触组0例。
- 接触组下沉2髋(0.5%),间隙组下沉2髋(12.5%)。
- 间隙组与接触组比较:下沉P = 0.0000282,假体周围骨折P = 0.0000584。
临床怎么用
- Dorr C型股骨使用带领全HA涂层非骨水泥柄时,术中应评估并尽量确保领-股骨距接触。
- 术后早期影像发现领-股骨距间隙者,应警惕假体周围骨折和下沉风险。
局限性
- 本研究为回顾性分析,事件绝对数较小。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Collared, fully hydroxyapatite-coated stems are designed to enhance axial and rotational stability through collar-calcar contact, reducing the risk for implant subsidence and periprosthetic fracture. The purpose of this study was to address the uncertainty surrounding the use of cementless stems in Dorr C femora by evaluating the association between collar-calcar gap with periprosthetic fracture and subsidence in patients who underwent THA through the direct anterior approach. METHODS: A retrospective analysis was performed on 6,107 total hip arthroplasties performed between September 2020 and June 2025. A total of 387 hips, with Dorr C femora, using collared, fully HA-coated stems, were included in this study. All surgeries were performed using the direct anterior approach. Radiographs were reviewed for the collar-calcar gap within 90 days postoperatively. Outcomes included the presence of periprosthetic femoral fracture (PPF) and/or subsidence. RESULTS: Full collar-calcar contact was observed in 371 hips (95.9%), while gaps were present in 16 hips (4.1%). There were three PPFs that occurred exclusively with patients who had a collar-calcar gap (18.8%) and were not observed in patients who had collar-calcar contact. Subsidence was present in two hips among the contact group (0.5%) and two hips among the gap group (12.5%). The presence of a gap is associated with higher rates of subsidence and periprosthetic fracture with the collar-calcar gap group as compared to the collar-calcar contact group (P = 0.0000282; P = 0.0000584). The absolute number of events is small; however, the effect size is clinically meaningful. CONCLUSION: The exclusive occurrence of early PPF and subsidence in the gap group underscores the mechanical importance of immediate load transfer through the collar. Our findings support intraoperative assessment of collar-calcar contact, especially in Dorr C bone, and reinforce the rationale for using collared, fully HA-coated, cementless stems when contact can be secured.
引用
- Navarro JAM, Miura Y, Oinuma K, et al. Collar-Calcar Contact Reduces Risk for Early Periprosthetic Fracture and Subsidence in Dorr Type C Femora Using Collared, Fully Hydroxyapatite-Coated, Cementless Stems. J Arthroplasty. 2026. PMID: 42486201. doi:10.1016/j.arth.2026.07.030
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。