文献速递关节外科

全髋关节置换术后急性期计时起立行走测试、10米步行测试和2分钟步行测试的最小临床重要差异

Minimal Clinically Important Difference of the Timed Up and Go Test, 10-Meter Walk Test, and 2-Minute Walk Test in Patients in the Acute Phase After Total Hip Arthroplasty.
PubMed 文献 · J Arthroplasty · 2026-06-29

本研究为前瞻性单组观察性研究,纳入100例全髋关节置换术后住院患者,于术后第1天和第3天进行计时起立行走测试(TUG)、10米步行测试(10MWT)和2分钟步行测试(2MWT),并用15点整体变化评分评估感知功能改善,采用锚定法和分布法估计最小临床重要差异(MCID)。结果显示TUG的MCID估计值为3.7至9.0秒,10MWT为0.06至0.25米/秒,2MWT为3.3至33.5米;TUG的区分能力可接受(AUC=0.73;95%CI:0.62至0.82),而10MWT(AUC=0.64)和2MWT(AUC=0.55)未达到可接受的区分阈值(AUC<0.70)。结论认为TUG在识别临床有意义的功能改善方面优于步行表现测试,这些MCID值为临床实践和研究提供了参考点。

要点

  • TUG的MCID估计值为3.7至9.0秒,10MWT为0.06至0.25米/秒,2MWT为3.3至33.5米。
  • TUG区分临床有意义改善的能力可接受(AUC=0.73;95%CI:0.62至0.82)。
  • 10MWT(AUC=0.64)和2MWT(AUC=0.55)未达到可接受的区分阈值(AUC<0.70)。

核心结论

  • TUG在识别全髋关节置换术后急性期临床有意义的功能改善方面区分能力高于10MWT和2MWT。
  • 本研究提供的MCID值可为临床实践和研究提供参考点。

研究设计与样本

  • 前瞻性单组观察性研究,纳入100例全髋关节置换术后住院患者。
  • 患者在术后第1天和第3天进行TUG、10MWT和2MWT测试。
  • 第二次评估后使用15点整体变化评分评估感知功能改善。
  • 采用锚定法(患者内、患者间和受试者工作特征曲线)和分布法估计MCID。

主要发现

  • TUG的MCID估计值为3.7至9.0秒,10MWT为0.06至0.25米/秒,2MWT为3.3至33.5米,各测试内不同方法间变异较大。
  • TUG的AUC为0.73(95%CI:0.62至0.82),区分能力可接受。
  • 10MWT的AUC为0.64,2MWT的AUC为0.55,均未达到可接受的区分阈值(AUC<0.70)。

关键数值与推荐

  • TUG的MCID估计范围为3.7至9.0秒。
  • 10MWT的MCID估计范围为0.06至0.25米/秒。
  • 2MWT的MCID估计范围为3.3至33.5米。
  • TUG的AUC=0.73(95%CI:0.62至0.82),10MWT的AUC=0.64,2MWT的AUC=0.55。

临床怎么用

  • 全髋关节置换术后急性期可采用TUG评估功能改善,其MCID参考值为3.7至9.0秒。
  • 10MWT和2MWT的MCID值也可参考,但其区分临床有意义改善的能力有限。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The recovery of mobility and ambulation are primary rehabilitative goals to allow for an early and safe discharge after total hip arthroplasty (THA). Although the timed up and go test (TUG), 10-meter walk test (10MWT), and 2-minute walk test (2MWT) are widely used performance-based tests to assess functional progress and readiness for discharge, their minimal clinically important difference (MCID) has never been investigated in the early phase after THA. The study aimed to determine the MCID of the TUG, 10MWT, and 2MWT in patients in the early postoperative phase after THA. METHODS: This prospective, single-group observational study included 100 inpatients who performed TUG, 10MWT, and 2MWT on the first and third postoperative days after THA. After the second evaluation session, participants rated their perceived functional improvement using a 15-point Global Rating of Change scale. MCIDs were estimated using anchor-based (within-patient, between-patient, and receiver operating characteristic curve) and distribution-based methods. RESULTS: The MCID estimates revealed high variability across methods within each test (TUG: 3.7 to 9.0 seconds; 10MWT: 0.06 to 0.25 meters/second; 2MWT: 3.3 to 33.5 meters). The TUG revealed acceptable discriminative ability for the detection of meaningful improvements (area under the curve (AUC) = 0.73; 95% confidence interval: 0.62 to 0.82). The 10MWT (AUC = 0.64) and 2MWT (AUC = 0.55) did not reveal an acceptable discriminative threshold, being AUC ˂0.70. CONCLUSIONS: The TUG revealed higher discriminative ability in identifying clinically meaningful functional improvements than walking performance tests. These MCID values provide useful reference points for clinical practice and research.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. De Leo D, Temporiti F, Guzzetti L, et al. Minimal Clinically Important Difference of the Timed Up and Go Test, 10-Meter Walk Test, and 2-Minute Walk Test in Patients in the Acute Phase After Total Hip Arthroplasty. J Arthroplasty. 2026. PMID: 42373020. doi:10.1016/j.arth.2026.06.062

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。