全髋关节置换术后EQ-5D-3L问卷存在中度天花板效应:术前预测因素与临床意义

The EQ-5D-3L Questionnaire Demonstrates Moderate Ceiling Effects at One and Two Years After Total Hip Arthroplasty: Preoperative Predictors and Clinical Implications.
PubMed 文献 · J Arthroplasty · 2026-06-19

本研究基于7871例初次全髋关节置换术(THA)的前瞻性队列,评估EQ-5D-3L问卷在术后1年和2年的天花板效应。结果显示术后1年47.5%、2年48.6%的患者达到天花板分数,术前EQ-5D≥0.534可预测术后天花板效应,且达到天花板者临床改善更显著。

要点

  • THA术后1年和2年EQ-5D-3L天花板效应分别为47.5%和48.6%,属中度。
  • 女性、年轻、社会经济剥夺低、术前OHS/EQ-5D/EQ-VAS高是天花板效应的独立预测因素。
  • 术前EQ-5D≥0.534可预测术后天花板效应(AUC 65.6%和64.1%)。

核心结论

  • EQ-5D-3L在THA术后1年和2年显示中度天花板效应,术前评分较高与达到天花板相关。
  • 达到天花板者从基线改善更大,更可能获得临床有意义结局。

研究设计与样本

  • 来自机构关节置换数据库的7871例初次THA队列,前瞻性收集术前及术后1、2年数据。
  • 采用回归分析确定与达到天花板分数独立相关的术前因素,并行ROC曲线分析。

主要发现

  • 术前EQ-5D中位数0.516,术后1年显著改善至0.850(P<0.001),2年无显著变化(中位数0.883,P=0.075)。
  • 天花板效应术后1年为47.5%(n=2,961),2年为48.6%(n=2,853)。
  • 女性、年轻、社会经济剥夺较低、术前OHS、EQ-5D、EQ-VAS较高是达到天花板EQ-5D的独立预测因素。
  • 术前EQ-5D≥0.534预测术后1年和2年天花板分数,AUC分别为65.6%和64.1%(P<0.001)。
  • 达到天花板者OHS、EQ-5D、EQ-VAS显著改善,更易达到最小重要变化和患者可接受症状状态。

关键数值与推荐

  • 术前EQ-5D评分≥0.534可预测术后1年和2年EQ-5D天花板效应。

临床怎么用

  • 对于术前EQ-5D较高的患者,应预期EQ-5D可能出现天花板效应,需结合OHS等其他工具评估改善。
  • 术前EQ-5D≥0.534可作为识别可能达到天花板效应患者的参考阈值。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The objectives were to evaluate whether the EQ-5D-3L questionnaire demonstrated a ceiling effect after total hip arthroplasty (THA), identify which patients were more likely to reach the ceiling score, and determine whether this limited assessment of potential improvement, relative to baseline, in their outcomes. METHODS: A cohort of 7,871 primary THAs was identified from an institutional arthroplasty database. Patient demographics, American Society of Anesthesiologists grade, socioeconomic status, Oxford Hip Score (OHS), and EQ-5D-3L were prospectively collected preoperatively and one and two years postoperatively. Regression analyses were performed to determine which preoperative factors were independently associated with achieving a ceiling score. RESULTS: The median preoperative EQ-5D-3L was 0.516, improving significantly at one year to 0.850 (P < 0.001), with nonsignificant change at two years (median, 0.883; P = 0.075). A ceiling effect was observed in 47.5% (n = 2,961) at one year, increasing to 48.6% (n = 2,853) at two years. Women, younger age, lower socioeconomic deprivation, and higher preoperative OHS, EQ-5D, and EQ-VAS were independent predictors of achieving a ceiling EQ-5D. Receiver operating characteristic curve analyses indicated that a preoperative EQ-5D score (≥ 0.534) predicted postoperative ceiling scores at one and two years (area under the receiver operating characteristic curve, 65.6 and 64.1%, respectively; P < 0.001). Patients who reached the postoperative EQ-5D ceiling had significant improvements in OHS, EQ-5D, and EQ-VAS and were more likely to achieve minimal important change and a patient-acceptable symptom state compared with those below the ceiling. CONCLUSIONS: The EQ-5D showed moderate ceiling effects at one and two years following THA, with higher preoperative scores being associated with ceiling attainment. Patients who reached the ceiling experienced greater improvements from baseline and were more likely to achieve clinically meaningful outcomes.