文献速递关节外科创伤骨科

计算机导航在全肩关节置换术中的应用:澳大利亚骨科协会国家关节置换登记分析

Computer navigation in total shoulder arthroplasty : analysis from the Australian Orthopaedic Association National Joint Replacement Registry.
PubMed 文献 · Bone Joint J · 2026-06-01

基于澳大利亚国家关节置换登记数据,比较单一设计平台假体行解剖型全肩关节置换(aTSA)和反式全肩关节置换(rTSA)时使用与不使用计算机导航的翻修率。共纳入5236例骨柄型全肩关节置换,整体翻修率无显著差异;但在2017年后匹配时间的rTSA中,导航与较低翻修率相关(HR 0.71, 95%CI 0.50-1.00, p=0.047)。

要点

  • aTSA中导航与未导航翻修率无显著差异。
  • 2017年后rTSA中导航与较低翻修率相关(HR 0.71)。
  • 需进一步评估长期临床结局和成本效益。

核心结论

  • 对于单一设计平台假体rTSA,自2017年引入导航后的时间匹配手术中,计算机导航较标准植入方法降低了早中期翻修率。
  • aTSA中未显示导航与未导航翻修率存在差异的证据。

研究设计与样本

  • 回顾性分析澳大利亚国家关节置换登记系统中2011年6月1日至2022年12月31日所有使用单一设计平台假体的初次骨柄型aTSA和rTSA。
  • 按计算机导航与无技术辅助分组,排除无柄手术,并自2017年1月31日起进行时间匹配亚组分析。

主要发现

  • 共纳入5236例初次骨柄型全肩关节置换,包括680例aTSA和4556例rTSA。
  • 计算机导航用于31.9%(217/680)的aTSA和50.7%(2312/4556)的rTSA。
  • 总体aTSA和rTSA中导航与未导航翻修率无显著差异。
  • 2017年后rTSA中导航与较低翻修率相关(整个时期HR 0.71, 95%CI 0.50-1.00, p=0.047)。
  • 按盂形态亚组分析未显示显著差异,死亡率和早期翻修数据不足以进一步分析。

关键数值与推荐

  • rTSA自2017年起时间匹配手术中导航组翻修率HR 0.71(95%CI 0.50-1.00, p=0.047)。
  • aTSA和总体rTSA中导航与未导航翻修率无显著差异。

临床怎么用

  • 对于单一设计平台假体rTSA,计算机导航可能降低早中期翻修率,但需进一步评估长期结局和成本效益后再常规推荐。
  • aTSA中导航的临床获益证据不足。

局限性

  • 死亡率和早期翻修数据不足,无法进一步分析。
  • 需进一步评估长期临床结局和成本效益。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

AIMS: Computer navigation is capable of improving the accuracy of glenoid baseplate and screw positioning in shoulder arthroplasty, but there is very limited evidence of its effect on clinical outcomes. In Australia, there is one commonly used total shoulder arthroplasty prosthesis with the option for intraoperative navigation. The aim of this study was to compare revision rates for a single prosthesis design, performed with or without computer navigation. METHODS: Data were obtained from a large national arthroplasty registry for all primary stemmed anatomical total shoulder arthroplasty (aTSA) and reverse total shoulder arthroplasty (rTSA) procedures using a single-design platform prosthesis (SDPP) from 1 June 2011 to 31 December 2022. Procedures were grouped by the use of computer navigation versus no technology assistance. Stemless procedures were excluded. A subgroup analysis included only procedures from 31 January 2017, when computer navigation for this device was first recorded, to enable a time-matched comparison. Further subanalyses assessed outcomes by glenoid morphology (from 2017) and mortality, limited to the first eligible procedure per patient. Kaplan-Meier estimates of survivorship described the time to first revision. Hazard ratios (HRs) from Cox proportional hazard models, adjusted for age and sex, were used to compare revision rates. RESULTS: There were 5,236 primary total stemmed shoulder arthroplasties, including 680 aTSAs and 4,556 rTSAs. Computer navigation was used in 31.9% (217/680) of aTSA and 50.7% (2,312/4,556) of rTSA cases. Overall, there was no significant difference in revision rates between computer-navigated and non-navigated procedures for aTSA or for rTSA. However, in rTSA cases performed since 2017, navigation was associated with a lower revision rate (entire period, HR 0.71 (95% CI 0.50 to 1.00); p = 0.047). Sub-group analyses by glenoid morphology showed no significant differences. Mortality and early revision data were insufficient for further analysis. CONCLUSION: Computer navigation demonstrated a reduction in early to mid-term revision rates compared with standard implantation methods for the SDPP rTSA for time-matched procedures since the technology was introduced in 2017. No evidence of a difference was shown for aTSA. Further evaluation of long-term clinical outcomes and cost-effectiveness is required before computer navigation can be routinely recommended.

来源:Bone Joint J,查看原文。版权归原作者所有。

引用

  1. Wilcox BM, Campbell RJ, Gill DRJ, et al. Computer navigation in total shoulder arthroplasty : analysis from the Australian Orthopaedic Association National Joint Replacement Registry. Bone Joint J. 2026. PMID: 42219176. doi:10.1302/0301-620X.108B6.BJJ-2025-1772.R1

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。