文献速递关节外科

机器人全髋关节置换术在髋关节非典型解剖中的应用:192例复杂病例的组件定位精度与临床结果

Robotic Total Hip Arthroplasty in Atypical Hip Anatomy: Accuracy of Component Positioning and Clinical Outcomes in 192 Complex Cases.
PubMed 文献 · J Arthroplasty · 2026-06-12

本研究纳入192例因发育性髋关节发育不良、Legg-Calve-Perthes病、股骨头骨骺滑脱、既往髋臼骨折或骨骼发育不良而行机器人全髋关节置换术的患者,评估组件定位精度、患者满意度、功能结果、假体生存率及并发症。结果显示机器人全髋关节置换术在非典型髋关节解剖患者中执行计划组件定位具有高精度,短期随访假体生存率满意、功能结果良好且并发症风险低。

要点

  • 机器人全髋关节置换术在非典型髋关节解剖中执行计划水平与垂直旋转中心的精度高。
  • 髋臼组件位于Lewinnek安全区的比例为94.7%,位于Callanan安全区的比例为93.8%。
  • 5年假体生存率为98.8%(95%CI:95.8至100),以任何原因翻修为终点。

核心结论

  • 机器人全髋关节置换术在非典型髋关节解剖患者中执行计划组件定位具有高精度,短期随访假体生存率、功能结果满意且并发症风险低。

研究设计与样本

  • 本研究纳入192例机器人全髋关节置换术,来自182例患者,包括发育性髋关节发育不良122例、Legg-Calve-Perthes病27例、股骨头骨骺滑脱20例、既往髋臼骨折12例和骨骼发育不良11例。
  • 平均随访时间为3.8±1.7年(范围2.1至5.4年)。

主要发现

  • 水平旋转中心均方根误差为1.5±1.4 mm,垂直旋转中心均方根误差为1.8±1.7 mm,联合偏心距均方根误差为2.9±3.8 mm,腿长矫正均方根误差为1.5±1.4 mm。
  • 髋臼组件位于Lewinnek安全区的比例为94.7%,位于Callanan安全区的比例为93.8%。
  • 末次随访时患者满意度中位数为90(四分位距85至95),WOMAC中位数为18(四分位距12至20),FJS平均为77.8±10.8。
  • 末次随访时UCLA活动评分(P < 0.001)和OHS(P < 0.001)均较术前改善。
  • 5年假体生存率为98.8%(95%置信区间:95.8至100),以任何原因翻修为终点。

临床怎么用

  • 对于非典型髋关节解剖患者,机器人全髋关节置换术可帮助实现计划组件定位,短期随访假体生存率和功能结果满意。

局限性

  • 本研究为短期随访(平均3.8±1.7年),长期结果仍需进一步观察。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The objectives of this study were to determine the accuracy of component positioning, patient satisfaction, functional outcomes, component survivorship, and complications of robotic total hip arthroplasty (THA) in patients who have atypical hip anatomy. METHODS: This study included 192 robotic THAs performed in 182 patients for developmental dysplasia of the hip (n = 122), Leg-Calve-Perthes disease (n = 27), slipped capital femoral epiphysis (n = 20), previous acetabular fracture (n = 12), and skeletal dysplasia (n = 11). Predefined radiological outcomes, patient satisfaction, University of California at Los Angeles (UCLA) activity score, Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), Oxford Hip Score (OHS), Forgotten Joint Score (FJS), component survivorship, and any complications were recorded. The mean follow-up time was 3.8 ± 1.7 years (range, 2.1 to 5.4). RESULTS: Robotic THA was associated with high levels of accuracy in executing the planned horizontal (root mean square error (RMSE) 1.5 ± 1.4 mm) and vertical centers of rotation (RMSE: 1.8 ± 1.7 mm), combined offset (RMSE: 2.9 ± 3.8 mm), and leg-length correction (RMSE: 1.5 ± 1.4 mm). Acetabular component positioning within Lewinnek's safe zones was 94.7%, and Callanan's safe zones were 93.8%. The median patient satisfaction score was 90 (interquartile range, 85 to 95), the median WOMAC score was 18 (interquartile range, 12 to 20), and the mean FJS score was 77.8 ± 10.8 at final follow-up. Robotic THA was associated with improvements in the mean UCLA (P < 0.001) and OHS (P < 0.001) at final follow-up. The 5-year survivorship was 98.8% (95% confidence interval: 95.8 to 100) with implant revision for any reason as the end point. CONCLUSIONS: Robotic THA in patients who have atypical hip anatomy was associated with high levels of accuracy in executing the planned component positioning. In this challenging patient population, robotic THA was associated with encouraging early component survivorship, satisfactory functional outcomes, and low risk of complications at short-term follow-up.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Kayani B, Enson J, Donaldson J, et al. Robotic Total Hip Arthroplasty in Atypical Hip Anatomy: Accuracy of Component Positioning and Clinical Outcomes in 192 Complex Cases. J Arthroplasty. 2026. PMID: 42285324. doi:10.1016/j.arth.2026.06.014

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。