文献速递关节外科

翻修全膝关节置换模块接口微动腐蚀是否真为问题?

Is Fretting Corrosion at the Modular Junction of Revision Total Knee Arthroplasty Actually a Problem?
PubMed 文献 · J Arthroplasty · 2026-06-02

本研究评估了98例翻修全膝关节置换患者取出的196个模块化柄-孔组件,发现锥形接口腐蚀显著重于螺纹设计(P < 0.001),但腐蚀严重程度与影像学局部组织反应或骨溶解表现无相关性,也与翻修指征无关。

要点

  • 锥形接口腐蚀较螺纹接口更显著(P < 0.001)。
  • 腐蚀严重程度与影像学表现及翻修原因不相关。
  • 腐蚀产物与全髋关节置换所见不同,提示机制不同。

核心结论

  • 锥形接口腐蚀显著多于螺纹接口,但腐蚀严重程度与影像学发现或失败病因无关。

研究设计与样本

  • 评估98例翻修全膝关节置换患者取出的196个模块化柄和孔组件,含锥形73个和螺纹25个。

主要发现

  • 锥形接口腐蚀重于螺纹设计(P < 0.001)。
  • 锥形股骨组件中位mGS为4,股骨柄为3,胫骨组件及柄均为2;螺纹接口所有界面中位评分为1。
  • 钴铬股骨孔锥形接口mGS为4者中位材料损失0.56 mm3,钛合金股骨和胫骨柄锥形接口中位损失分别为0.071 mm3和0.067 mm3。
  • 腐蚀严重程度与局部影像学表现或翻修指征无相关性。

关键数值与推荐

  • 锥形接口中位在位时间24个月,螺纹接口15个月(P = 0.052)。
  • 假体周围感染和无菌性松动是最常见取出指征。

临床怎么用

  • 翻修全膝关节置换术中锥形接口腐蚀常见,但当前未发现其与影像学损害或失败原因相关,临床需结合其他因素综合判断。

局限性

  • 回顾性取出物研究,样本有限,随访时间较短,需进一步研究明确临床意义。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Corrosion at modular junctions in total knee arthroplasty (TKA) implants is recognized, but its clinical relevance remains unclear. This study evaluated corrosion at modular stem-bore junctions and examined whether severity correlated with radiographic evidence of adverse local tissue reactions or osteolysis. METHODS: We evaluated 196 retrieved modular stem and bore components from 98 revision TKA patients, including taper (n = 73) and threaded (n = 25) designs. The median time in situ was 24 months for taper and 15 months for threaded junctions (P = 0.052). Periprosthetic joint infection and aseptic loosening were the most common indications for component explantation. Fretting corrosion at the modular junction was graded using a modified Goldberg Score (mGS) and quantified using an optical coordinate measuring machine. Radiographs were evaluated. Statistical analyses included Mann-Whitney U-, Chi-Square, and Spearman's correlation tests. RESULTS: Taper junctions demonstrated greater corrosion than threaded designs (P < 0.001). The median mGS for modular tapers was 4 for femoral components, 3 for femoral stems, and two for both tibial components and stems. Threaded junctions showed minimal damage across all interfaces with a median score of 1. Damage patterns included fretting wear, corrosion features, and dark deposits. Among cobalt-chromium (CoCr) femoral bore tapers with mGS of 4, median material loss was 0.56 mm3. Titanium alloy femoral and tibial stem tapers showed a median loss of 0.071 mm3, and 0.067 mm3, respectively. Corrosion severity did not correlate with localized radiographic findings or indication for revision. CONCLUSIONS: In this study of modular TKA components, taper junctions exhibited significantly more corrosion than threaded junctions. However, corrosion severity was not associated with radiographic findings or etiology of failure. Corrosion products differed from those typically observed in THA, suggesting a distinct mechanism. Further research is required to clarify potential clinical implications.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Hall DJ, Wong J, Wright JL, et al. Is Fretting Corrosion at the Modular Junction of Revision Total Knee Arthroplasty Actually a Problem? J Arthroplasty. 2026. PMID: 42235616. doi:10.1016/j.arth.2026.05.069

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。