直接前入路初次全髋关节置换术后脱位危险因素分析
基于15年间8658例直接前入路(DAA)初次全髋关节置换术(THA)的单机构回顾性研究,总体脱位率为0.5%(45/8656)。女性脱位率高于男性(0.7%对0.2%),Cox回归显示女性使用28mm股骨头(HR 7.5;95%CI 3.2-17.6)和32mm股骨头(HR 3.8;95%CI 1.9-7.5)脱位风险增加。影像学分析显示对照组髋臼杯外倾角方差显著更低(P=0.01),强调精确杯定位的重要性。
要点
- DAA入路初次THA总体脱位率低(0.5%),但女性使用小直径股骨头脱位风险显著增加。
- 女性28mm股骨头脱位HR为7.5(95%CI 3.2-17.6),32mm股骨头HR为3.8(95%CI 1.9-7.5)。
- 对照组髋臼杯外倾角方差显著更低(P=0.01),精确杯定位可能降低脱位风险。
核心结论
- DAA入路THA后脱位发生率低,但女性使用较小直径股骨头是脱位的独立危险因素。
- 髋臼杯外倾角的精确性可能与脱位风险相关,对照组方差显著更低。
研究设计与样本
- 单机构回顾性队列研究,纳入2009年3月至2024年5月由4名术者完成的8658例DAA初次THA。
- 采用Cox比例风险回归分析患者人口学与假体特征与脱位的关联,并将脱位患者与匹配对照比较影像学参数。
主要发现
- 全部初次THA的脱位率为0.5%(45/8656)。
- 女性脱位率高于男性(0.7%对0.2%)。
- Cox回归显示女性使用28mm股骨头脱位风险HR 7.5(95%CI 3.2-17.6),32mm股骨头HR 3.8(95%CI 1.9-7.5)。
- 总偏心距(P=0.13)和肢体长度变化(P=0.41)在脱位组与对照组间无显著差异。
- 对照组髋臼杯外倾角方差显著低于脱位组(P=0.01)。
关键数值与推荐
- 女性使用28mm股骨头:HR 7.5(95%CI 3.2-17.6)。
- 女性使用32mm股骨头:HR 3.8(95%CI 1.9-7.5)。
- 髋臼杯外倾角方差组间比较P=0.01。
- 总偏心距组间比较P=0.13,肢体长度变化组间比较P=0.41。
临床怎么用
- 对女性患者行DAA入路THA时,应关注股骨头直径选择以降低脱位风险。
- 术中应力求髋臼杯外倾角的精确放置,减少过度变异。
局限性
- 单机构回顾性研究,结果外推需谨慎。
- 脱位事件数较少(45例),统计效能有限。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: While the direct anterior approach (DAA) for total hip arthroplasty (THA) is associated with a lower risk of dislocation, this complication has not been eliminated and can be acutely disabling when it occurs. This study aimed to identify patient, surgical, and radiographic factors that contribute to dislocation risk for the DAA based on primary THAs performed over a 15-year period. METHODS: Using an institutional database, we identified 8,658 DAA THAs performed by four surgeons from March 2009 through May 2024. A Cox proportional hazards regression was performed to determine how patient demographics and implant characteristics were associated with dislocation. Patients who dislocated were also compared to a matched control cohort without dislocation to evaluate the influence of radiographic parameters, including acetabular cup orientation, offset, limb length changes, and preoperative acetabular coverage. RESULTS: The dislocation rate among all primary THAs was 0.5% (45 of 8,656). Women had a higher dislocation rate than men (0.7 versus 0.2%), and Cox regression identified an increased risk among women with 28 mm (hazard ratio 7.5; 95% confidence interval 3.2 to 17.6) and 32 mm heads (hazard ratio 3.8; 95% confidence interval 1.9 to 7.5). Radiographic analysis showed no significant differences in total offset (P = 0.13) or limb-length change (P = 0.41), but controls demonstrated significantly lower variance in cup inclination (P = 0.01). CONCLUSIONS: Although the incidence of dislocation after THA using the DAA is low, women who have smaller diameter femoral heads are at increased risk of dislocation. The significantly lower variance in radiographic inclination among controls also underscores the importance of precise cup positioning.
引用
- Murphy MP, Forti CR, Ho H, et al. What Factors Increase the Risk of Dislocation After Primary Total Hip Arthroplasty Using the Direct Anterior Approach? J Arthroplasty. 2026. PMID: 42285325. doi:10.1016/j.arth.2026.06.017
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。