文献速递关节外科

全髋关节置换术中巨型股骨头:早期稳定性改善且不增加并发症

Jumbo Femoral Heads in Total Hip Arthroplasty: Improved Early Stability Without Added Complications.
PubMed 文献 · J Arthroplasty · 2026-06-10

本研究纳入单中心6413例使用大直径股骨头的初次全髋关节置换术,比较36mm传统大直径与40或44mm巨型股骨头的脱位风险及早期并发症。结果显示巨型股骨头在术后第一年脱位风险较低,但全程随访无显著差异,且不增加早期并发症。

要点

  • 巨型股骨头(40或44mm)在术后第一年脱位风险低于36mm股骨头。
  • 全程随访中巨型股骨头与36mm股骨头的脱位风险无显著差异。
  • 巨型股骨头未增加术后90天、一年及末次随访的并发症发生率。

核心结论

  • 与传统大直径股骨头(36mm)相比,巨型股骨头(40或44mm)在术后第一年提供适度且短暂的脱位风险降低,但未提供额外的长期保护。
  • 巨型股骨头未增加早期手术并发症的发生率。

研究设计与样本

  • 按股骨头直径分为传统大直径组(36mm,n=5897)和巨型股骨头组(40或44mm,n=516),中位随访2.4年(范围0.1至9.8,四分位距1.3至4.1)。

主要发现

  • 全程随访中,巨型股骨头与36mm股骨头相比,调整后脱位风险无显著降低(风险比0.55,95%置信区间0.13至2.34,P=0.139)。
  • 术后第一年分析中,40或44mm股骨头与36mm股骨头相比,脱位风险较低(风险比0.20,95%置信区间0.05至0.79,P=0.032)。
  • 术后90天脱位风险无显著差异。
  • 术后90天、一年及末次随访时,假体周围感染和骨折等并发症发生率两组相似。

临床怎么用

  • 对于接受全髋关节置换术的患者,可考虑使用巨型股骨头(40或44mm)以在术后第一年降低脱位风险,尤其在后路手术入路后。
  • 巨型股骨头不增加早期并发症风险,但不应期望其提供长期额外保护。

局限性

  • 本研究为单中心回顾性研究,随访时间有限,需更长期研究以解决历史担忧。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Larger femoral heads have been proposed to reduce dislocation risk following total hip arthroplasty (THA). While the benefit of increasing head size from 28 or 32 mm to ≥ 36 mm is well established, it remains unclear whether jumbo (40 or 44 mm) femoral heads confer additional stability over traditional large (36 mm) heads. This study aimed to determine whether jumbo heads improve stability or alter early complication rates. METHODS: We identified 6,413 primary THAs with large-diameter femoral heads (36-, 40-, or 44-mm) implanted at a single institution between February 1, 2016 and December 31, 2022. Cases were stratified by femoral head diameter into the traditional large-head (36 mm, n = 5,897) and jumbo-head (40 or 44 mm, n = 516) groups. The median follow-up was 2.4 years (range, 0.1 to 9.8; interquartile range, 1.3 to 4.1). The primary outcome was prosthetic hip dislocation at the last clinical follow-up. Time-to-event analyses were performed using multivariable Cox models with surgeon-level random effects, adjusting for patient-specific factors, year of surgery, surgical approach, and robotic assistance. RESULTS: In the full follow-up period, jumbo heads were not associated with a lower adjusted dislocation risk (hazard ratio: 0.55 [95% confidence interval: 0.13 to 2.34], P = 0.139) when compared with 36 mm heads. When analysis was truncated to the first postoperative year, 40 or 44 mm heads were associated with a lower dislocation risk compared with 36 mm heads (hazard ratio: 0.20 [95% confidence interval: 0.05 to 0.79], P = 0.032). There were no significant differences in dislocation risk observed at 90 days. Rates of postoperative complications (periprosthetic joint infection and fracture) were similar between groups at 90 days, one year, and last follow-up. CONCLUSIONS: Compared with traditional large heads (36 mm), jumbo heads (40 or 44 mm) provided a modest, transient reduction in dislocation risk during the first postoperative year, most evident following the posterior approach THA, but did not confer additional long-term protection. Jumbo heads were not associated with increased rates of early surgical complications. Longer-term studies are warranted to address historical concerns.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Kim BI, Cheng R, Grabov EH, et al. Jumbo Femoral Heads in Total Hip Arthroplasty: Improved Early Stability Without Added Complications. J Arthroplasty. 2026. PMID: 42269951. doi:10.1016/j.arth.2026.06.007

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。