AI从常规X线片估算骨密度与DXA在10年真实世界队列中预测骨折的比较
本研究回顾性分析540名同时接受腰椎DXA和X线检查的成人,评估AI从常规X线片估算的骨密度与DXA的一致性及骨折预测能力。结果显示两者强相关(r=0.943),AI诊断骨质疏松的AUC为0.959,预测椎体、髋部及全身骨折的AUC与DXA相当或略高。
要点
- AI估算骨密度与DXA强相关(r=0.943,ICC=0.934)。
- AI诊断骨质疏松的AUC为0.959,准确率90%。
- AI预测全身骨折的AUC略高于DXA(0.699 vs 0.677,P=0.042)。
核心结论
- AI从常规X线片估算的骨密度与DXA高度相关,骨折预测能力相当或略优,可支持机会性骨质疏松筛查。
主要发现
- AI与DXA骨密度强相关(r=0.943;ICC=0.934)。
- AI诊断骨质疏松(T值≤-2.5)的AUC为0.959,κ=0.74,准确率90%。
- AI与DXA预测椎体骨折的AUC分别为0.704和0.678,预测髋部骨折的AUC分别为0.716和0.678。
- AI预测全身骨折的AUC略高于DXA(0.699 vs 0.677;P=0.042)。
- 较低的AI估算骨密度与更高的骨折风险独立相关。
关键数值与推荐
- 骨质疏松定义为T值≤-2.5。
- AI诊断骨质疏松的AUC为0.959,κ=0.74,准确率90%。
- AI与DXA预测椎体骨折的AUC分别为0.704和0.678。
- AI与DXA预测髋部骨折的AUC分别为0.716和0.678。
- AI与DXA预测全身骨折的AUC分别为0.699和0.677(P=0.042)。
临床怎么用
- 可利用常规X线片进行机会性骨质疏松筛查,辅助识别骨折高风险个体。
- AI估算骨密度可作为DXA的补充工具,减少对专用DXA检查的依赖。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
UNLABELLED: AI-derived bone mineral density from routine radiographs showed strong agreement with DXA and comparable ability to predict incident fractures. This opportunistic approach may support osteoporosis screening and early identification of high-risk individuals without reliance on dedicated DXA examinations. INTRODUCTION: Osteoporosis is a major cause of fragility fractures, yet limited access to DXA leads to underdiagnosis and delayed treatment. Recent advances in artificial intelligence enable extraction of bone structural information from routine radiographs, providing a potential tool for opportunistic osteoporosis screening. Whether AI-derived BMD can approximate DXA and predict real-world fracture risk remains unclear. METHODS: Adults aged ≥ 20 years who underwent both lumbar DXA and radiographic examinations (lumbosacral or kidney-ureter-bladder) within six months between January 2014 and December 2024 were retrospectively analyzed. Lumbar BMD was estimated using DeepXray Spina and compared with DXA using Pearson correlation, intraclass correlation coefficient (ICC), and Bland-Altman analysis. Diagnostic performance for osteoporosis (T-score ≤ - 2.5) and fracture prediction was evaluated using receiver operating characteristic (ROC) analysis, Cohen's κ, and logistic regression. RESULTS: Among 540 participants (73.9% female; mean age 57.0 years; mean follow-up 6.4 years), AI- and DXA-derived BMD showed strong agreement (r = 0.943; ICC = 0.934). For osteoporosis diagnosis, AI-derived T-scores achieved an AUC of 0.959, κ = 0.74, and 90% accuracy. AI- and DXA-derived BMD showed comparable performance for predicting vertebral (AUC 0.704 vs. 0.678) and hip fractures (0.716 vs. 0.678). For all-site fractures, AI-derived BMD showed a modestly higher AUC than DXA-derived BMD (AUC, 0.699 vs 0.677; P = 0.042). Lower AI-derived BMD was independently associated with higher fracture risk. CONCLUSIONS: AI-derived BMD from routine radiographs closely correlates with DXA and demonstrates comparable fracture prediction. This approach may support opportunistic osteoporosis screening without reliance on DXA.
引用
- Tseng TH, Huang TT, Huang JE, et al. AI-derived bone mineral density from standard radiographs compared with DXA for fracture prediction in a 10-year real-world cohort study. Osteoporos Int. 2026. PMID: 42313179. doi:10.1007/s00198-026-08100-8
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。