文献速递运动医学关节外科

前交叉韧带重建术中手动阻力与关节内直视确认股骨悬吊纽扣的回顾性队列研究

Intraoperative Manual Resistance and Direct Intra-articular Visualization Maneuvers for Anterior Cruciate Ligament Reconstruction: A Retrospective Cohort Study.
PubMed 文献 · Am J Sports Med · 2026-04-14

本研究回顾性纳入922例使用股骨悬吊固定装置的前交叉韧带重建患者,术中仅用人工阻力和关节内直视确认纽扣部署,结果显示100%患者纽扣正确展开,3.9%纽扣位置不良,固定环与可调环之间无差异,提示该法可避免术中透视。

要点

  • 922例ACLR中,人工阻力联合关节内直视确认纽扣,100%正确展开。
  • 纽扣位置不良率为3.9%,固定环与可调环装置间无差异。
  • ACLR类型(初次vs翻修)和移植物类型与纽扣位置不良无关。

核心结论

  • 术中人工阻力联合关节内直视手法是ACLR中有效部署股骨悬吊纽扣装置的方法。
  • 该手法下纽扣未展开和位置不良率低,不支持常规使用术中透视成像。

研究设计与样本

  • 回顾性队列研究,证据等级3级。
  • 纳入单机构3名运动医学专科医生施行的ACLR患者,使用前瞻性收集的行政数据库识别。
  • 排除未使用悬吊固定装置或无术后X线片的患者。

主要发现

  • 共922例患者符合纳入标准,所有922例(100.0%)纽扣装置正确展开。
  • 36例(3.9%)患者纽扣位置不良(中心距股骨皮质>2 mm)。
  • 固定环与可调环纽扣装置的位置不良率无差异。
  • ACLR类型(初次vs翻修)及移植物类型与纽扣位置不良无相关性。

关键数值与推荐

  • 装置部署不当定义为X线片上纽扣未翻转。
  • 纽扣位置不良定义为纽扣中心距股骨皮质测量>2 mm。

临床怎么用

  • ACLR术中可用人工阻力联合关节内直视确认股骨悬吊纽扣部署,无需常规透视。
  • 该手法可能使手术更安全、更快且更具成本效益。

局限性

  • 回顾性设计,证据等级3级。
  • 仅纳入使用悬吊固定装置且有术后X线片的患者。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The use of femoral suspensory fixation devices is a popular technique in anterior cruciate ligament reconstruction (ACLR), but there is no consensus on the best intraoperative method for confirming proper button deployment. Recent literature suggests that manual resistance alone is at a high risk of causing button malpositioning or floating without utilizing intraoperative fluoroscopic imaging. PURPOSE: To investigate the incidence of femoral suspensory button malpositioning in patients undergoing ACLR when intraoperative manual resistance and direct intra-articular visualization maneuvers without imaging are used to confirm fixation as well as to compare the rates of button malpositioning between fixed- and adjustable-loop fixation devices. STUDY DESIGN: Cohort study; Level of evidence, 3. METHODS: All patients who underwent ACLR by 3 board-certified, sports medicine fellowship-trained orthopaedic surgeons at a single institution were included. All 3 surgeons used intraoperative manual resistance and direct intra-articular visualization maneuvers to verify button device positioning. Patients were identified using prospectively collected administrative data from an institutional orthopaedic database. Patients were excluded if they did not have suspensory fixation devices used for reconstruction or if they lacked postoperative radiographs. Improper device deployment was defined as a button that was not flipped on radiography; malpositioned buttons were defined as those whose centers measured >2 mm from the femoral cortex. RESULTS: A total of 922 patients met inclusion criteria for this study. All 922 patients (100.0%) had properly deployed button devices, and 36 patients (3.9%) had malpositioned buttons. There was no difference in the rates of button malpositioning between fixed- and adjustable-loop button devices. Neither ACLR type (primary vs revision) nor graft type correlated with button malpositioning. CONCLUSION: Intraoperative manual resistance and direct intra-articular visualization maneuvers were an effective method for properly deploying suspensory button devices during ACLR. The low rates of improper deployment and malpositioning with these maneuvers do not warrant the use of intraoperative fluoroscopic imaging, resulting in safer, faster, and more cost-effective surgical procedures for patients.

来源:Am J Sports Med,查看原文。版权归原作者所有。

引用

  1. Cantrell WA, Hale ME, Scariano G, et al. Intraoperative Manual Resistance and Direct Intra-articular Visualization Maneuvers for Anterior Cruciate Ligament Reconstruction: A Retrospective Cohort Study. Am J Sports Med. 2026. PMID: 41981829. doi:10.1177/03635465261431311

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。