高偏距股骨柄增加股骨松动翻修与全因翻修风险:一项登记系统回顾性队列研究
该研究基于国家登记系统93,027例非骨水泥全髋关节置换术(THA),评估总股骨偏距(TFO)对早期无菌性股骨松动(AFL)翻修和全因翻修(ACR)风险的影响。高偏距组(>48 mm)10年AFL生存率较低,校正混杂后TFO每增加1 mm,AFL翻修风险增加4.1%,高偏距组AFL翻修风险增加83%、ACR风险增加20%;带领股骨柄与翻修风险降低50%相关。
要点
- 高偏距(>48 mm)与AFL翻修风险(HR 1.83)和ACR风险(HR 1.20)显著增加相关。
- TFO每增加1 mm,AFL翻修风险增加4.1%(HR 1.04,95%CI 1.02–1.06)。
- 带领股骨柄与翻修风险降低50%相关。
核心结论
- 在非骨水泥THA中,较高的TFO组合与AFL翻修风险增加83%和ACR风险增加20%相关。
- 带领股骨柄与翻修风险降低50%相关。
研究设计与样本
- 回顾性队列研究,使用国家登记系统2012–2024年因骨关节炎行初次非骨水泥THA的数据,纳入五种最常用股骨柄设计。
- 最终队列93,027髋,观察到AFL翻修419例、ACR翻修2,592例。
主要发现
- 高偏距组(>48 mm)10年AFL生存率98.9%(95%CI 98.6–99.1),低于标准组99.3%(95%CI 99.2–99.4)和低偏距组99.5%(95%CI 99.4–99.6),P<0.001。
- 校正混杂后,TFO每增加1 mm,AFL翻修风险增加4.1%(HR 1.04,95%CI 1.02–1.06)。
- 高偏距组(>48 mm)AFL翻修风险显著增加(HR 1.83,95%CI 1.28–2.63),ACR风险显著增加(HR 1.20,95%CI 1.04–1.38)。
关键数值与推荐
- TFO分为三组:<42 mm、42–48 mm、>48 mm。
- 主要终点为AFL翻修,次要终点为ACR。
临床怎么用
- 在非骨水泥THA中应关注TFO组合,避免过高偏距以降低早期AFL翻修和ACR风险。
- 带领股骨柄可能有助于降低翻修风险。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: The influence of femoral offset on the survival of cementless femoral stems in total hip arthroplasty (THA) remains unclear. This study aimed to evaluate the influence of total femoral offset (TFO - stem plus head) on the risk of revision for early aseptic femoral loosening (AFL) and all-cause revision (ACR). METHODS: A retrospective cohort study was conducted using data from a national registry for all primary, cementless THAs performed for osteoarthritis between 2012 and 2024 with the five most common stem designs. The final cohort consisted of 93,027 hips, and a total of 419 revisions for AFL and 2,592 for ACR were observed. The primary exposure was TFO, analyzed as both a continuous variable and as three categories (less than 42 mm, 42 to 48 mm, and greater than 48 mm). The primary endpoint was revision surgery for AFL, and the secondary endpoint was ACR. Kaplan-Meier survival analyses and multivariable Cox proportional hazards models were used to estimate survival and hazard ratios (HRs) while adjusting for confounders. RESULTS: The 10-years implant survival for AFL was significantly lower in the high-offset group (98.9%, 95% confidence interval (CI) 98.6 to 99.1) compared to the standard (99.3%, 95% CI 99.2 to 99.4) and low-offset groups (99.5%, 95% CI 99.4 to 99.6; P < 0.001). After adjusting for confounders, the risk of revision for AFL increased by 4.1% for every 1-mm increase in TFO (HR 1.04, 95% CI 1.02 to 1.06). The high-offset group (greater than 48 mm) had a significantly increased risk of revision for AFL (HR 1.83, 95% CI 1.28 to 2.63) and ACR (HR 1.20, 95% CI 1.04 to 1.38). CONCLUSIONS: In this registry population, higher TFO combinations are associated with an 83 and 20% increased risk of revision for aseptic femoral loosening and a risk of all-cause revision following cementless THA. Collars were associated with a 50% reduction in revision risk.
引用
- Oettl FC, Andronic O, Dimitriou D, et al. High-Offset Stems Are Associated With an Increase in Revision due to Femoral Loosening and All-Cause: A Registry-Based Observational Retrospective Cohort Study. J Arthroplasty. 2026. PMID: 41999789. doi:10.1016/j.arth.2026.04.024
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。