后路无辅助技术置入非组配双动髋臼杯的两年随访结果
本研究回顾性分析604例初次全髋关节置换术,使用骨水泥型非组配双动髋臼杯,均由同一术者经后路无辅助技术完成。平均随访2.0年,假体生存率99.8%,无脱位发生,6例翻修中仅1例涉及髋臼杯。结论支持该假体在后路无辅助技术下可实现稳定固定。
要点
- 非组配双动髋臼杯经后路无辅助技术置入,平均2年随访无脱位。
- 无菌性髋臼杯假体生存率99.8%,仅1例(0.2%)因髋臼杯脱离骨盆翻修。
- 6例翻修中其余5例未涉及髋臼杯,包括股骨假体周围骨折、股骨松动和急性假体周围感染。
核心结论
- 骨水泥型非组配双动髋臼杯在初次全髋关节置换中平均随访2.0年,临床结果优异,604例中无脱位,假体生存率高。
研究设计与样本
- 单臂回顾性研究,纳入2017年4月至2024年8月单中心同一髋关节外科医生连续604例初次择期全髋关节置换术,均经后路无辅助技术置入骨水泥型非组配双动髋臼杯,随访至少90天。
主要发现
- 平均随访2.0年(范围0.25至8.0年),全因和无菌性髋臼杯假体生存率均为99.8%。
- 研究期间共6例翻修,其中1例(0.2%)因髋臼杯脱离骨盆翻修。
- 其余翻修包括2例股骨假体周围骨折(0.3%)、1例股骨松动(0.2%)和2例急性假体周围感染(0.3%),均未涉及髋臼杯翻修。
- 未观察到脱位,无患者因不稳定需要翻修。
临床怎么用
- 对于初次全髋关节置换术,骨水泥型非组配双动髋臼杯可作为一种实现假体稳定和持久固定的可行选择,即使采用后路且无辅助技术。
局限性
- 本研究为单中心、单术者、单臂回顾性设计,平均随访仅2.0年,缺乏对照组。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Nonmodular dual mobility (DM) articulations in total hip arthroplasty (THA) aim to reduce dislocations through a large outer bearing diameter while minimizing wear via a smaller inner bearing where most motion occurs. Although routine use remains uncommon in the United States, this construct may protect against dislocation. This study aimed to evaluate clinical outcomes of a cementless, nonmodular DM acetabular cup at a mean follow-up of two years. METHODS: We conducted a single-arm retrospective review of 604 primary, elective THAs using a cementless nonmodular DM acetabular cup between April 2017 and August 2024 at a single health system with at least 90 days of follow-up. All surgeries were performed by a single hip surgeon via posterior approach. Cases were planned using digital templating and performed with manual instruments without enabling technology. Clinical outcomes were collected, including 90-days readmission and revision rates, reasons for readmission and revision, and dislocation rates. RESULTS: At a mean follow-up of 2.0 years (range, 0.25 to 8.0), all-cause and aseptic acetabular cup implant survivorship was 99.8%. There were six revisions during the study period. There was one acetabular component (0.2%) that was revised due to cup dissociation from the pelvis. The remaining revisions included two for periprosthetic femoral fracture (0.3%), one for femoral loosening (0.2%), and two for acute periprosthetic joint infection (0.3%), none of which involved revision of the acetabular cup. There were no dislocations observed, and no patients required revision for instability. CONCLUSIONS: Cementless nonmodular DM acetabular cups offered excellent clinical outcomes in primary THA at a mean follow-up of 2.0 years, with no observed dislocations in 604 cases and high implant survivorship. These findings support the use of nonmodular DM implants as a viable option to achieve THA implant stability and durable fixation even when using a posterior approach without enabling technology.
引用
- Sundaram V, Saba BV, White AJ, et al. Outcomes of a Cementless Nonmodular Dual Mobility Acetabular Cup Inserted via Posterior Approach Without Technology: Mean Two-Year Follow-Up. J Arthroplasty. 2026. PMID: 42001914. doi:10.1016/j.arth.2026.04.020
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。