文献速递关节外科创伤骨科

高孔隙率金属翻修杯联合骨水泥双动轴承减少复杂髋臼重建后不稳

Highly Porous Metal Revision Cup With a Cemented Dual Mobility Bearing Reduces Instability Following Complex Acetabular Reconstructions: A Minimum Two-Year Follow-Up.
PubMed 文献 · J Arthroplasty · 2026-04-17

本研究回顾性分析33例(32例患者)复杂髋臼缺损(Paprosky 3A/3B或骨盆不连续)翻修全髋关节置换,采用高孔隙率钽金属半球杯联合骨水泥双动衬里重建。平均随访48个月(24-84个月),无脱位发生,无无菌性松动或任何原因翻修的总体假体生存率为95%(95%CI:71-97),所有临床评分显著改善。

要点

  • 高孔隙率金属杯联合骨水泥双动衬里在复杂髋臼重建中短期无脱位。
  • 假体生存率95%(95%CI:71-97),无无菌性松动或任何原因翻修。
  • 所有临床评分(HHS、WOMAC、SF-12)从术前到末次随访显著改善。

核心结论

  • 高孔隙率金属杯联合骨水泥双动衬里可有效减少复杂髋臼重建后的不稳定性。
  • 短期随访显示无菌性松动或任何原因翻修率低。

研究设计与样本

  • 回顾性分析前瞻性收集的机构关节登记数据,纳入33例翻修全髋关节置换(32例患者),平均随访48个月(范围24-84个月)。
  • 纳入标准为复杂或翻修全髋关节置换涉及主要髋臼缺损(Paprosky 3A和3B或骨盆不连续),采用高孔隙率钽金属半球杯联合不锈钢双动骨水泥衬里重建。

主要发现

  • 队列中无脱位发生。
  • 包括脱位、无菌性松动和任何原因翻修的总体假体生存率为95%(95%CI:71-97)。
  • 所有临床 outcome 评分从术前到末次随访显著改善,包括髋关节 Harris 评分、WOMAC 骨关节炎指数、SF-12 生理和心理评分。

关键数值与推荐

  • 不稳定性定义为需要闭合或开放复位的任何髋关节脱位。
  • 假体生存率评估包括无无菌性松动生存率和无任何原因再手术生存率。

临床怎么用

  • 对于Paprosky 3A/3B或骨盆不连续的复杂髋臼缺损,可考虑采用高孔隙率金属杯联合骨水泥双动衬里以降低脱位风险。
  • 短期随访中该技术显示出低翻修率,但需注意95%CI较宽(71-97),提示样本量有限。

局限性

  • 回顾性研究设计,样本量较小(33例髋)。
  • 随访时间较短(平均48个月,最短24个月),缺乏长期耐久性数据。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The aim of this study was to look at instability following complex acetabular reconstructions using a highly porous metal cup with a cemented dual mobility bearing for the reconstruction of large acetabular defects. The secondary outcomes were survivorship free of aseptic loosening and all-cause revision. METHODS: We retrospectively reviewed our prospectively collected institutional joint registry to look at patients who had complex or revision total hip arthroplasties involving major acetabular defects (Paprosky 3A and 3B, or pelvic discontinuity) who underwent acetabular reconstruction using a highly porous tantalum hemispherical cup with a stainless steel dual mobility cemented liner. Instability was defined as any hip dislocation requiring closed or open reduction. Survivorship free of aseptic loosening and any-cause reoperation was also assessed. A total of 33 revision THAs in 32 patients were identified with a minimum of a 2-year follow-up and a mean follow-up of 48 months (range, 24 to 84). RESULTS: There were no dislocations in the cohort. The overall implant survivorship for revision, including dislocations, aseptic loosening, and any-cause revisions, was 95% (95% confidence interval: 71 to 97). All clinical outcome scores improved significantly from preoperative scores to the latest follow-up, including the Hip Harris Score, Western Ontario and McMaster Universities Osteoarthritis Index, Short Form-12 Physical and Mental scores. CONCLUSIONS: Our series of 33 hips reconstructed using a cemented dual mobility liner within a highly porous metal shell works well to mitigate instability, the most frequent complication seen in these complex reconstructions at short-term follow-up. Our series also confirms low rates of aseptic or all-cause revision at a minimum of two years of follow-up of all patients.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Kooner P, Algarni N, Tanzer M, et al. Highly Porous Metal Revision Cup With a Cemented Dual Mobility Bearing Reduces Instability Following Complex Acetabular Reconstructions: A Minimum Two-Year Follow-Up. J Arthroplasty. 2026. PMID: 41999794. doi:10.1016/j.arth.2026.03.099

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。