文献速递关节外科

无镍Oxinium低致敏假体与含钴铬标准全膝关节置换术后滑液金属离子比较

The James A. Rand Young Investigator's Award: "Nickel-Free" Oxinium Hypoallergenic Versus Standard Cobalt-Chrome-Containing Total Knee Arthroplasty: Is There a Difference in Synovial Metal Ions at Minimum of Two-Year Follow-Up?
PubMed 文献 · J Arthroplasty · 2026-04-01

回顾性匹配病例对照研究比较低致敏Oxinium假体与标准钴铬假体全膝关节置换术后至少2年滑液金属离子水平,发现低致敏组镍离子中位数是标准组的3.6倍,而钴和铬离子分别低17.7倍和3.2倍,功能评分无差异。

要点

  • 低致敏Oxinium假体组滑液镍离子中位数1.0 ug/L,是标准钴铬组0.28 ug/L的3.6倍。
  • 低致敏组钴离子中位数0.07 ug/L,比标准组1.24 ug/L低17.7倍。
  • 两组牛津膝关节评分和遗忘关节评分无显著差异。

核心结论

  • 低致敏Oxinium假体全膝关节置换术后滑液镍离子水平是标准钴铬假体的3.6倍。
  • 结果不支持对镍过敏/敏感患者使用该手工器械植入的Oxinium低致敏假体。
  • 若钴等金属碎屑导致的局部组织不良反应成为更大问题,数据支持使用该低致敏假体。

研究设计与样本

  • 回顾性匹配病例对照研究,使用单中心前瞻性收集数据。
  • 共纳入22例低致敏Oxinium假体(金属过敏/敏感)和18例标准钴铬假体对照。
  • 中位随访4.9年(范围2.2至6.1年),两组按年龄、性别、体质指数、ASA分级、初次置换指征、股骨假体设计、髌骨置换及术后时间匹配(P > 0.05)。

主要发现

  • 低致敏组滑液镍离子中位数1.0 ug/L,标准组0.28 ug/L,P < 0.001。
  • 低致敏组滑液钴离子中位数0.07 ug/L,标准组1.24 ug/L,P < 0.001。
  • 低致敏组滑液铬离子中位数0.39,标准组1.26,P < 0.001。
  • 牛津膝关节评分P = 0.577,遗忘关节评分P = 0.675,两组相似。

临床怎么用

  • 对镍过敏/敏感患者,不应选择该手工器械植入的Oxinium低致敏假体。
  • 若关注钴等金属碎屑所致局部组织不良反应,可考虑使用该低致敏假体。

局限性

  • 回顾性设计,样本量较小(22例和18例),需进一步确定性研究。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Allergy and adverse local tissue reaction (ALTR) to metal debris may both be modes of failure in total knee arthroplasty (TKA). Yet, the intra-articular synovial fluid metal ion levels in well-fixed implants beyond the first postoperative day remain unknown. The aim of this study was to compare intraarticular synovial fluid levels of metal ions in patients who had a hypoallergenic TKA implant versus a matched cohort with a standard cobalt-chromium (Co-Cr)-containing TKA implant at a minimum 2-year follow-up. METHODS: A retrospective, matched, case-control study was performed using prospectively collected data from a single institution. A total of 22 cases (metal allergy/sensitivity with Oxinium hypoallergenic TKA implants) and 18 controls (standard Co-Cr TKA implants) were enrolled, who had a median follow-up of 4.9 years (range, 2.2 to 6.1). Cases and controls were matched for age, sex, body mass index, American Society of Anesthesiologists classification, indication for primary TKA, femoral component design, patellar resurfacing, and time from TKA surgery (P > 0.05). Synovial fluid from aseptic aspirations of the study knees was analyzed for metal ion levels of cobalt (Co), chromium (Cr), nickel (Ni), and titanium (Ti). Well-fixed implants were confirmed radiographically, and functional outcomes were analyzed. RESULTS: The median Ni ion level in the synovial fluid of the hypoallergenic cases was 3.6 times higher than standard Co-Cr-containing implant controls (1.0 versus 0.28 ug/L, P < 0.001). Cobalt ion levels in the hypoallergenic cases were 17.7 times lower than the controls (0.07 versus 1.24 ug/L, P < 0.001). Similarly, the Cr ion levels in synovial fluid of the hypoallergenic case knees were 3.2 times lower than control knees (0.39 versus 1.26, P < 0.001). The Oxford Knee Score (P = 0.577) and Forgotten Joint Score (P = 0.675) were similar between cohorts. CONCLUSIONS: Patients who had hypoallergenic implants had intra-articular synovial Ni ion levels 3.6 times higher versus standard implant controls. Our results do not support the use of this Oxinium hypoallergenic implant performed using manual instrumentation for patients who have a Ni allergy/hypersensitivity. However, if ALTR metal debris such as Co does become a bigger issue in TKA, our data support the use of the hypoallergenic implant. Further definitive study on the subject matter is necessary and warranted.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Neufeld ME, Sheridan GA, Sidhu A, et al. The James A. Rand Young Investigator's Award: "Nickel-Free" Oxinium Hypoallergenic Versus Standard Cobalt-Chrome-Containing Total Knee Arthroplasty: Is There a Difference in Synovial Metal Ions at Minimum of Two-Year Follow-Up? J Arthroplasty. 2026. PMID: 41963219. doi:10.1016/j.arth.2026.03.001

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。