初次全髋关节置换术中钛套筒大股骨头假体至少两年生存率分析

Minimum Two-Year Survivorship of Large Femoral Heads With Titanium Sleeves in Primary Total Hip Arthroplasty: An Analysis From the American Joint Replacement Registry.
PubMed 文献 · J Arthroplasty · 2026-04-22

基于美国关节置换登记系统2012至2021年213749例65岁以上初次全髋关节置换术患者数据,分析陶瓷股骨头联合钛套筒对翻修风险的影响。结果显示36mm钛套筒股骨头全因翻修率高于无套筒(HR 1.34,95%CI 1.13-1.59,P<0.001),主要由脱位翻修增加驱动;≥40mm无套筒股骨头翻修率高于36mm无套筒(HR 1.28,95%CI 1.07-1.54,P<0.008),但≥40mm带套筒与36mm无套筒无差异(HR 1.00,95%CI 0.70-1.44,P=0.991)。

要点

  • 36mm陶瓷股骨头使用钛套筒与全因翻修风险增加相关,主要由脱位翻修驱动。
  • ≥40mm无套筒股骨头较36mm无套筒翻修风险更高,涉及感染、脱位、磨损和机械并发症。
  • ≥40mm带套筒股骨头与36mm无套筒的全因翻修风险无差异。

核心结论

  • 36mm陶瓷股骨头使用钛套筒与全因翻修风险增加相关。
  • ≥40mm无套筒股骨头较36mm无套筒翻修风险增高,但≥40mm带套筒与36mm无套筒无差异。
  • 翻修风险似乎主要受股骨头尺寸影响。

研究设计与样本

  • 回顾性队列分析美国关节置换登记系统2012年1月至2021年12月初次全髋关节置换术病例。
  • 纳入213749例使用陶瓷股骨头、年龄至少65岁且随访至少2年的患者。
  • 按股骨头尺寸分为≤28mm、32mm、36mm和≥40mm组,其中9%(18685例)使用钛套筒。
  • 采用病因特异性Cox模型评估全因翻修风险,校正年龄、性别、体重指数和Charlson合并症指数。

主要发现

  • 钛套筒的存在影响股骨头尺寸与全因翻修的关系(P=0.013)。
  • 36mm带套筒股骨头全因翻修率高于36mm无套筒(HR 1.34,95%CI 1.13-1.59,P<0.001),由脱位翻修增加驱动。
  • ≥40mm无套筒股骨头全因翻修率高于36mm无套筒(HR 1.28,95%CI 1.07-1.54,P<0.008),由感染、脱位、磨损和机械并发症翻修增加驱动。
  • ≥40mm带套筒与36mm无套筒全因翻修无差异(HR 1.00,95%CI 0.70-1.44,P=0.991)。

关键数值与推荐

  • 36mm带套筒vs无套筒全因翻修HR 1.34(95%CI 1.13-1.59,P<0.001)。
  • ≥40mm无套筒vs36mm无套筒全因翻修HR 1.28(95%CI 1.07-1.54,P<0.008)。
  • ≥40mm带套筒vs36mm无套筒全因翻修HR 1.00(95%CI 0.70-1.44,P=0.991)。
  • 钛套筒与股骨头尺寸对全因翻修交互作用P=0.013。

临床怎么用

  • 初次全髋关节置换术选择36mm陶瓷股骨头时,应谨慎评估钛套筒的使用。
  • 选用≥40mm股骨头时,钛套筒可能降低翻修风险至与36mm无套筒相当的水平。
  • 股骨头尺寸是翻修风险的重要影响因素,决策时需结合尺寸与套筒使用综合考量。

局限性

  • 仅纳入65岁及以上患者,结论外推至年轻患者需谨慎。
  • 回顾性登记数据分析,可能存在未测量混杂因素。
  • 随访至少2年,长期结果未知。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Ceramic femoral heads with titanium sleeves (TSs) are used in revision total hip arthroplasty (THA) with femoral component retention to reduce the risk of femoral head fracture and trunnion corrosion. Their utility in primary THA, particularly for larger heads, is unknown. We sought to evaluate the influence of TSs on the risk of revision total hip arthroplasty based on ceramic head size. METHODS: All primary THAs using ceramic heads (n = 213,749) reported to the American Joint Replacement Registry from January 2012 to December 2021 in patients at least 65 year old who had a minimum 2-year follow-up were analyzed. The THAs were categorized as using ≤ 28 mm (millimeter), 32 mm, 36 mm, or ≥ 40 mm femoral heads. There were 9% of the cases (n = 18,685) that utilized TS. Cause-specific Cox models were used to determine the risk of all-cause revision, accounting for age, sex, body mass index, and the Charlson Comorbidity Index. RESULTS: Femoral head size influenced all-cause revision based on the presence of TS (P = 0.013). The 36 mm heads with TS had a higher all-cause revision rate than the 36 mm heads without TS (hazard ratio [HR] 1.34, 95% confidence interval [CI] 1.13 to 1.59, P < 0.001), driven by increased rates of revision for dislocation. Femoral heads ≥ 40 mm without TS had a higher all-cause revision rate than 36 mm heads without TS (HR 1.28, 95% CI 1.07 to 1.54, P < 0.008), driven by increased rates of revision for infection, dislocation, wear, and mechanical complications. There was no difference in all-cause revision between ≥ 40-mm heads with TS and 36 mm heads without TS (HR 1.00, 95% CI 0.70 to 1.44, P = 0.991). CONCLUSIONS: Use of TS is associated with increased risk of revision with 36 mm ceramic heads. Compared to 36 mm heads, ≥ 40 mm heads without TS are associated with increased risk of revision, but there is no difference using ≥ 40 mm heads with TS. Risk of revision appears to be most influenced by head size. These findings should be considered when deciding on the use of TS in primary THA.