定制化假体与现成假体在初次全膝关节置换术中临床与功能结果比较的倾向性匹配分析
本研究通过倾向性匹配分析比较了定制化个性化(CIM)全膝关节置换(TKA)假体与现成(OTS)假体在临床结果及患者报告结局测量(PROMs)达到最小临床重要差异(MCID)比例方面的差异。结果显示,CIM组术前和术后部分PROMs评分较高,但两组评分变化及达到临床有意义改善或恶化的比例相似,且90天、1年和2年并发症率无差异。结论提示CIM假体与OTS假体在基于MCID阈值评估的临床和患者感知结果上相似。
要点
- CIM与OTS假体在PROMs评分变化及达到MCID的比例上无显著差异。
- 两组90天、1年和2年并发症率相似。
- CIM组术前和术后部分PROMs评分较高,但临床意义有限。
核心结论
- 基于MCID阈值评估,CIM假体与OTS假体在临床和患者感知结果上相似。
研究设计与样本
- 单机构回顾性队列研究,纳入2,474例连续初次TKA,经1:3最近邻倾向性评分匹配后纳入258例CIM和774例OTS患者。
主要发现
- CIM组术前和术后SF-10a、PROMIS Global Mental和PROMIS Global Physical评分较高(P < 0.05),术前KOOS-PF评分较高(P < 0.05)。
- 两组所有PROMs评分变化及临床有意义改善和恶化的比例相似(P > 0.05)。
- 两组90天、1年和2年并发症率相似(P > 0.05)。
关键数值与推荐
- 使用基于分布的方法计算MCID,评估PROMs达到临床有意义变化的比例。
临床怎么用
- 研究结果可用于术前患者咨询,帮助患者在CIM和OTS假体之间做出知情选择。
局限性
- 回顾性研究设计可能引入选择偏倚,尽管进行了倾向性匹配。
- 单机构研究结果外推性受限。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Customized individually made (CIM) total knee arthroplasty (TKA) implants are designed using preoperative computed tomography to optimize component fit, mechanical alignment, and joint line restoration. Despite their theoretical advantages, clinical adoption and evidence demonstrating meaningful functional benefits over off-the-shelf (OTS) implants are limited. This study aimed to compare clinical outcomes and rates of achieving the minimal clinically important difference (MCID) in patient-reported outcome measures (PROMs) between CIM and OTS implants using a propensity-matched analysis. METHODS: A retrospective cohort study was conducted at a single institution following Institutional Review Board approval. Among 2,474 consecutive primary TKAs, 258 CIM and 774 OTS patients were identified using 1:3 nearest-neighbor propensity score matching based on demographic and comorbidity variables. The Patient-Reported Outcomes Measurement Information System (PROMIS) Physical Function Short Form 10-a (SF-10a), PROMIS Global-Physical, PROMIS Global-Mental, and Knee Injury and Osteoarthritis Outcome Score-Physical Function Shortform was collected for analysis. The proportions of clinically meaningful change were calculated with MCID using the distribution-based method. The 90-day, and 1- and 2-year complication rates were recorded. After matching, there were no differences in baseline demographics between groups (P > 0.05). RESULTS: Customized TKA patients had higher preoperative and postoperative SF-10a, PROMIS Global Mental, and PROMIS Global Physical scores (P < 0.05) and higher preoperative Knee Injury and Osteoarthritis Outcome Score-Physical Function Shortform scores (P < 0.05) when compared to OTS patients. Similar changes in scores and proportions of clinically meaningful improvement and worsening were seen between groups in all PROMs (P > 0.05). Similar 90-day, 1-year, and 2-year complication rates were present in both groups (P > 0.05). CONCLUSIONS: This study demonstrated that CIM implants were associated with similar clinical and patient-perceived outcomes compared to OTS implants when evaluated using MCID-based thresholds. These findings may inform preoperative patient counseling for individuals considering TKA.
引用
- Ilyas MH, Freeman IA, Sampson WT, et al. Do Customized Implants Yield Superior Clinical and Functional Outcomes Compared to Off-the-Shelf Implants in Primary Total Knee Arthroplasty? A Propensity-Matched Analysis. J Arthroplasty. 2026. PMID: 41997309. doi:10.1016/j.arth.2026.04.034
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。