膝关节假体周围感染滑液外送检测组合的诊断准确性评估
该研究评估了外送滑液检测组合(NGS或α-防御素)与机构内滑液白细胞计数及中性粒细胞百分比在疑似膝关节假体周围感染中的诊断准确性。研究发现外送NGS组合的白细胞计数显著低于机构内检测,但绝大多数结果不改变ICM次要标准阈值,两种外送组合对慢性PJI诊断具有较高敏感性和特异性。
要点
- 外送NGS组合的白细胞计数较机构内检测显著降低58.6%,α-防御素组合降低4.4%。
- 仅1.9%的外送白细胞计数和4.2%的中性粒细胞百分比改变了ICM次要标准阈值。
- NGS组合诊断PJI的敏感性0.923、特异性1.000;α-防御素组合敏感性0.970、特异性0.857。
核心结论
- 来自NGS和α-防御素检测组合的滑液细胞计数及分类值可用于慢性PJI的可靠诊断。
主要发现
- 外送NGS组合白细胞计数较机构内检测低58.6%(SD 39.2%),α-防御素组合低4.4%(SD 30.1%),p<0.001。
- 中性粒细胞百分比在两种外送组合中与机构内检测相似(NGS -0.1%,α-防御素 1.2%;p=0.365)。
- 仅4例(1.9%)外送白细胞计数和9例(4.2%)外送中性粒细胞百分比改变了ICM次要标准阈值,仅1例(0.5%)从「感染」转为「可能感染」。
- NGS组合诊断PJI的敏感性0.923、特异性1.000;α-防御素组合敏感性0.970、特异性0.857。
关键数值与推荐
- 采用2018年国际共识会议(ICM)慢性PJI阈值评估滑液白细胞计数和中性粒细胞百分比的一致性。
临床怎么用
- 临床可依赖外送NGS或α-防御素检测组合的滑液细胞计数及分类结果辅助诊断慢性膝关节PJI。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
AIMS: Although synovial fluid send-out laboratory panels are increasingly used in the diagnosis of periprosthetic joint infection (PJI), the impact of transportation delays on the accuracy of synovial fluid white blood cell (WBC) count and polymorphonuclear neutrophil percentage (%PMN) remains unclear. The aim of this study was to assess the accuracy of two send-out synovial panels compared with institutional synovial WBC count and differential in patients evaluated for total knee arthroplasty (TKA) PJI. METHODS: Between October 2015 and July 2023, all patients with a suspect TKA PJI with both an institutional synovial cell count and a corresponding next-generation sequencing (NGS) or α-defensin result, derived from separate aliquots of the same aspirate, were assessed. Synovial WBC count, %PMN, synovial CRP, α-defensin, serum CRP, serum ESR, and D-dimer were extracted from institutional and send-out laboratory results. The concordance of synovial WBC count and %PMN values was assessed using the 2018 International Consensus Meeting (ICM) thresholds for chronic PJI. Sensitivity, specificity, positive predictive value, and negative predictive value were calculated to evaluate the diagnostic performance of the institutional and send-out analyses. RESULTS: In total, 212 TKAs (44 (20.8%) next-generation sequencing (NGS), 168 (79.2%) α-defensin) were identified. Relative to institutional analysis, send-out WBC counts were significantly lower (NGS -58.6% (SD 39.2%), α-defensin -4.4% (SD 30.1%); p < 0.001), whereas %PMN was similar for both (NGS -0.1%, α-defensin 1.2%; p = 0.365). Despite these differences, only four (1.9%) send-out WBC counts and nine (4.2%) send-out %PMN values altered ICM minor criteria thresholds, switching from 'Infected' to 'Possibly infected' only once (0.5%). The WBC and %PMN counts from the NGS panel had a sensitivity of 0.923 and a specificity of 1.000, while the α-defensin panel had a sensitivity of 0.970 and a specificity of 0.857 for diagnosing PJI. CONCLUSION: Synovial fluid cell count and differential values obtained from NGS and α-defensin panels are reliable for diagnosing chronic PJI.
引用
- Palmer RC, Dobitsch A, Aron A, et al. Assessing the diagnostic accuracy of synovial fluid send-out laboratory panels for suspected knee periprosthetic joint infection. Bone Joint J. 2026. PMID: 41916545. doi:10.1302/0301-620X.108B4.BJJ-2024-1345.R2
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。